{"title":"Backflow Devices - Febco - DCVA - Double Check Valve Assemblies - 1 1\/4\"","description":null,"products":[{"product_id":"1-1-4-lf850-qt-fz-dc","title":"1 1\/4 LF850-QT-FZ DC","description":"\u003cp\u003eThis \u003cstrong\u003e1 1\/4 inch Lead Free double check valve backflow preventer assembly\u003c\/strong\u003e is designed to prevent the backflow of polluted water from entering the potable water supply due to backsiphonage and or backpressure. It is ideal for protection in continuous pressure piping applications and at cross-connections identified as non-health hazards, such as at the service line entrance.\u003c\/p\u003e\u003cp\u003eIts \u003cstrong\u003ecompact modular design\u003c\/strong\u003e facilitates easy maintenance with a single access cover for in-line repairs, ensuring efficient servicing without removing the entire assembly from the line.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Free* construction\u003c\/strong\u003e to comply with Lead Free installation requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact modular design\u003c\/strong\u003e facilitates maintenance with a single access cover for in-line repairs\u003c\/li\u003e\n\u003cli\u003eTwo in-line independent positive seating check modules\u003c\/li\u003e\n\u003cli\u003eReplaceable seats and seat discs\u003c\/li\u003e\n\u003cli\u003eTop-mounted test cocks\u003c\/li\u003e\n\u003cli\u003eQuarter turn ball valve shutoffs\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFreeze Sensor Technology\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIncludes a \u003cstrong\u003efreeze sensor\u003c\/strong\u003e for use with \u003cstrong\u003eSentryPlus Alert® technology\u003c\/strong\u003e to signal facility personnel when temperature nears and reaches the freezing point.\u003c\/li\u003e\n\u003cli\u003eThe freeze alerts feature is available with an add-on connection kit (sold separately) for Wi-Fi networks, building management systems (BMS), and irrigation management systems (IMS).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e The freeze sensor solely provides alerts about a possible freeze event and cannot prevent a freeze event from occurring. User action is required to prevent freeze conditions from causing product and\/or property damage.\u003c\/em\u003e\u003c\/p\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796813390101,"sku":"T683041","price":1046.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/185255.jpg?v=1773078308"},{"product_id":"1-1-4-lf850u-qt-fz-dc","title":"1 1\/4 LF850U-QT-FZ DC","description":"\u003cp\u003eThis \u003cstrong\u003e1 1\/4 inch lead free double check valve backflow preventer assembly\u003c\/strong\u003e is designed to prevent the backflow of polluted water from entering the potable water supply due to \u003cstrong\u003ebacksiphonage\u003c\/strong\u003e and \u003cstrong\u003ebackpressure\u003c\/strong\u003e. It is ideal for protection in continuous pressure piping applications and at cross-connections identified as non-health hazards.\u003c\/p\u003e\u003cp\u003eThe assembly includes a \u003cstrong\u003efreeze sensor\u003c\/strong\u003e for use with SentryPlus Alert® technology to signal facility personnel when temperature nears and reaches the freezing point.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConstruction \u0026amp; Design\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eConstructed with a \u003cstrong\u003eLead Free cast copper silicon alloy body\u003c\/strong\u003e for durability and compliance with Lead Free installation requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact modular design\u003c\/strong\u003e facilitates easy maintenance with a single access cover for in-line repairs.\u003c\/li\u003e\n\u003cli\u003eFeatures two \u003cstrong\u003eindependently operating, spring-loaded check valves\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConnections \u0026amp; Components\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEquipped with \u003cstrong\u003eunion end connections\u003c\/strong\u003e and \u003cstrong\u003equarter turn ball valve shutoffs\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003etop mounted test cocks\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eFeatures two \u003cstrong\u003ein-line independent positive seating check modules\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eComes with \u003cstrong\u003ereplaceable check discs and seats\u003c\/strong\u003e, and \u003cstrong\u003ecaptured springs\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFreeze Sensor Information\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThe included freeze sensor monitors temperature and alerts facility personnel to potential freeze conditions.\u003c\/li\u003e\n\u003cli\u003eAn \u003cem\u003eadd-on connection kit is required (sold separately)\u003c\/em\u003e to activate the freeze sensor for communication via Wi-Fi, Building Management Systems (BMS), or Irrigation Management Systems (IMS).\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e The freeze sensor solely provides alerts about a possible freeze event and cannot prevent a freeze event from occurring. User action is required to prevent freeze conditions from causing product and\/or property damage.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796816896277,"sku":"T122966","price":1317.01,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/185248.jpg?v=1773078145"},{"product_id":"1-1-4-850-qt-fz-dc","title":"1 1\/4 850-QT-FZ DC","description":"\u003cp\u003eThis \u003cstrong\u003e1 1\/4 inch small diameter double check valve backflow preventer assembly\u003c\/strong\u003e is designed to prevent the backflow of polluted water from entering into the potable water supply due to backsiphonage and\/or backpressure in accordance with national plumbing codes and water authority requirements. It is ideal for protection in continuous pressure piping applications and at cross-connections identified as non-health hazards and for contaminants at the service line entrance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIncludes a \u003cstrong\u003efreeze sensor\u003c\/strong\u003e for use with \u003cstrong\u003eSentryPlus Alert® technology\u003c\/strong\u003e to monitor temperature and alert facility personnel when freeze conditions can cause damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBronze body\u003c\/strong\u003e construction for durability.\u003c\/li\u003e\n\u003cli\u003eModular compact design facilitates easy maintenance with a single access cover for in-line repairs.\u003c\/li\u003e\n\u003cli\u003eConsists of two in-line independent positive seating check modules and captured springs.\u003c\/li\u003e\n\u003cli\u003eEquipped with \u003cstrong\u003eNPT end connections\u003c\/strong\u003e and \u003cstrong\u003equarter-turn ball valve shutoffs\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eFeatures top-mounted test cocks and replaceable check discs and seats.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eWARNING: It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eWARNING: The freeze sensor solely provides alerts about a possible freeze event and cannot prevent a freeze event from occurring. User action is required to prevent freeze conditions from causing product and\/or property damage. Use of the freeze sensor does not replace the need to comply with all required instructions, codes, and regulations related to installation, operation, and maintenance of this product, including the need to provide protection against a freeze event.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796819419413,"sku":"T1114","price":884.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/185238.jpg?v=1773075646"}],"url":"https:\/\/www.backflowpreventer.com\/collections\/backflow-devices-febco-dcva-double-check-valve-assemblies-1-1-4.oembed","provider":"Water Specialties Company","version":"1.0","type":"link"}