{"title":"Backflow Devices - Febco - RPZ - Reduced Pressure Zone Assemblies - 8\" - 880W Series","description":null,"products":[{"product_id":"8-lf880w-dosy-rp-fs","title":"8 LF880W-DOSY RP-FS","description":"\u003cp\u003eThis 8 inch lead free MasterSeries® configurable reduced pressure zone backflow preventer assembly is designed to protect potable water systems from high hazard (toxic) backpressure and backsiphonage conditions in industrial installations and applications.\u003c\/p\u003e\u003cp\u003eIt offers a longer lay-length for convenient drop-in replacement of competitor’s N-pattern valves.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eN-pattern\u003c\/strong\u003e configuration for drop-in replacement of competitor valves\u003c\/li\u003e\n\u003cli\u003eIncludes a \u003cstrong\u003eflood sensor\u003c\/strong\u003e with \u003cstrong\u003eSentryPlus Alert® technology\u003c\/strong\u003e to detect excessive water discharges from the relief valve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel relief valve seat\u003c\/strong\u003e and \u003cstrong\u003estainless steel check components\u003c\/strong\u003e for maximum performance and durability\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eModular and repairable pressure differential relief valve\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eField reversible relief valve\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaptured modular spring assembly\u003c\/strong\u003e and \u003cstrong\u003eclapper check assembly\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eReversible and replaceable discs\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eField replaceable seats\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInline serviceable assembly\u003c\/strong\u003e; no special tools required\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuctile iron valve body\u003c\/strong\u003e design\u003c\/li\u003e\n\u003cli\u003eIron components are coated with \u003cstrong\u003eArmorTek®\u003c\/strong\u003e, a patented three-part advanced epoxy system engineered to reduce microbial-induced corrosion (MIC) and protect exposed metal substrate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Free construction\u003c\/strong\u003e to comply with low lead installation requirements (wetted surface contains less than 0.25% of lead by weight)\u003c\/li\u003e\n\u003cli\u003eEquipped with \u003cstrong\u003edomestic OSY resilient seated gate valves\u003c\/strong\u003e and test cocks\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFlood Sensor Technology\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlood sensor\u003c\/strong\u003e detects continuous discharge from the relief valve\u003c\/li\u003e\n\u003cli\u003eAn add-on connection kit (sold separately) is required to activate the flood sensor, enabling it to relay alerts for potential flooding events via BMS, cellular communication, or integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi\u003c\/li\u003e\n\u003c\/ul\u003e\u003cem\u003e\u003cp\u003eAn add-on connection kit is required to activate the flood sensor. Without the connection kit, the flood sensor is a passive component that does not communicate with any other device. The flood sensor does not replace the need to comply with all required instructions, codes, and regulations related to installation, operation, and maintenance of this product, including the need to provide proper drainage in the event of a discharge.\u003c\/p\u003e\u003c\/em\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796686643477,"sku":"F8007371","price":39229.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/179048.jpg?v=1772726708"},{"product_id":"8-lf880w-lg-rp-fs","title":"8 LF880W-LG RP-FS","description":"\u003cp\u003eThis 8 inch lead free MasterSeries® Reduced Pressure Zone (RPZ) backflow preventer assembly is designed to protect potable drinking water systems from contamination by high hazard (toxic) fluids in industrial installations and applications.\u003c\/p\u003e\u003cp\u003eIt features a longer gate-to-gate length for drop-in replacement of competitor’s N-pattern valves and is supplied without shutoff valves.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Free\u003c\/strong\u003e construction to comply with low lead installation requirements\u003c\/li\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003edrop-in replacement\u003c\/strong\u003e of competitor's N-pattern valves due to longer gate-to-gate length\u003c\/li\u003e\n\u003cli\u003eDurable \u003cstrong\u003eductile iron valve body\u003c\/strong\u003e design with \u003cstrong\u003eArmorTek®\u003c\/strong\u003e coating for corrosion resistance of internal and external surfaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel relief valve seat\u003c\/strong\u003e and \u003cstrong\u003estainless steel check components\u003c\/strong\u003e for maximum performance and durability\u003c\/li\u003e\n\u003cli\u003eIntegrated \u003cstrong\u003eflood sensor\u003c\/strong\u003e with \u003cstrong\u003eSentryPlus Alert®\u003c\/strong\u003e technology to detect excessive water discharges from the relief valve\u003c\/li\u003e\n\u003cli\u003eInline serviceable assembly; no special tools required\u003c\/li\u003e\n\u003cli\u003eSupports vertical up or vertical down \u003cstrong\u003eN-pattern installation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCaptured modular spring assembly; clapper check assembly\u003c\/li\u003e\n\u003cli\u003eReversible and replaceable discs\u003c\/li\u003e\n\u003cli\u003eField replaceable seats\u003c\/li\u003e\n\u003cli\u003eModular and repairable pressure differential relief valve\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFlood Sensor Details\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThe flood sensor relays a signal that triggers a multichannel alert (call, email, text) to notify personnel about potential flooding.\u003c\/li\u003e\n\u003cli\u003eAn add-on connection kit (sold separately) is required to activate the flood sensor.\u003c\/li\u003e\n\u003cli\u003eConnection kit options include \u003cstrong\u003eBMS\u003c\/strong\u003e, cellular communication, and the \u003cstrong\u003eSensor Control Monitor\u003c\/strong\u003e which enables integration with \u003cstrong\u003eBAS\u003c\/strong\u003e via RS-485 Modbus or the \u003cstrong\u003eNexa®\u003c\/strong\u003e platform through Wi-Fi.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eImportant Warnings\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cem\u003eAn add-on connection kit is required to activate the flood sensor. Without the connection kit, the flood sensor is a passive component that does not communicate with any other device.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eUse of the flood sensor does not replace the need to comply with all required instructions, codes, and regulations related to installation, operation, and maintenance of this product, including the need to provide proper drainage in the event of a discharge.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eWatts® is not responsible for the failure of alerts due to connectivity issues, power outages, or improper installation.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eThe information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. Inquire with governing authorities for local installation requirements.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796689133845,"sku":"F8007372","price":24520.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/179160.jpg?v=1772726797"},{"product_id":"8-lf880wz-lg-rp-fs","title":"8 LF880WZ-LG RP-FS","description":"\u003cp\u003eThis \u003cstrong\u003e8 inch Lead Free MasterSeries Reduced Pressure Zone Backflow Preventer Assembly\u003c\/strong\u003e is designed to protect potable water systems from high hazard (toxic) fluids caused by backpressure and backsiphonage in industrial installations and applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLonger gate-to-gate length\u003c\/strong\u003e for \u003cstrong\u003edrop-in replacement\u003c\/strong\u003e of competitor's Z-pattern valves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel relief valve seat\u003c\/strong\u003e and \u003cstrong\u003estainless steel check components\u003c\/strong\u003e for maximum performance and durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInline serviceable assembly\u003c\/strong\u003e requiring no special tools.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuctile iron valve body design\u003c\/strong\u003e with \u003cstrong\u003eArmorTek® coating technology\u003c\/strong\u003e to resist corrosion of internals, including microbial-induced corrosion (MIC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular and repairable pressure differential relief valve\u003c\/strong\u003e with \u003cstrong\u003ecaptured modular spring assembly\u003c\/strong\u003e and \u003cstrong\u003eclapper check assembly\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReversible and replaceable discs\u003c\/strong\u003e and \u003cstrong\u003efield replaceable seats\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eCapable of \u003cstrong\u003evertical up N-pattern\u003c\/strong\u003e and \u003cstrong\u003evertical up Z-pattern\u003c\/strong\u003e installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFlood Sensor Technology\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIncludes a \u003cstrong\u003eflood sensor\u003c\/strong\u003e with \u003cstrong\u003eSentryPlus Alert® technology\u003c\/strong\u003e to detect excessive water discharges from the relief valve.\u003c\/li\u003e\n\u003cli\u003eThe sensor relays a signal for multichannel alerts (call, email, text) to notify personnel of potential flooding.\u003c\/li\u003e\n\u003cli\u003eRequires an \u003cstrong\u003eadd-on connection kit\u003c\/strong\u003e (BMS, cellular communication, or Sensor Control Monitor for BAS\/Nexa® platform Wi-Fi) to activate and communicate flood alerts. Without a connection kit, the sensor is passive.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eImportant Notice:\u003c\/strong\u003e The flood sensor does not replace the need to comply with all required installation, operation, and maintenance instructions, codes, and regulations, including proper drainage in the event of a discharge. Watts® is not responsible for alert failures due to connectivity issues, power outages, or improper installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796691394837,"sku":"F8007384","price":24520.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/179248.jpg?v=1772726865"},{"product_id":"8-lf880wz-dosy-rp-fs","title":"8 LF880WZ-DOSY RP-FS","description":"\u003cp\u003eThis 8 inch \u003cstrong\u003eLead Free\u003c\/strong\u003e MasterSeries reduced pressure zone backflow preventer assembly protects potable water systems from high hazard (toxic) fluids in industrial installations and applications by guarding against backpressure and backsiphonage conditions.\u003c\/p\u003e\u003cp\u003eThis assembly is engineered to provide a \u003cstrong\u003edrop-in replacement\u003c\/strong\u003e for competitor's Z-pattern valves, featuring a longer gate-to-gate lay length.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Free\u003c\/strong\u003e construction complies with low lead installation requirements (wetted surface contains less than 0.25% lead by weight).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuctile iron\u003c\/strong\u003e valve body design with \u003cstrong\u003eArmorTek® coating technology\u003c\/strong\u003e on internal and external surfaces to resist electrochemical and microbial-induced corrosion.\u003c\/li\u003e\n\u003cli\u003eEquipped with a \u003cstrong\u003eflood sensor\u003c\/strong\u003e with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. When activated with an add-on connection kit, the sensor relays alerts to personnel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel relief valve seat\u003c\/strong\u003e and \u003cstrong\u003estainless steel check components\u003c\/strong\u003e ensure maximum performance and durability.\u003c\/li\u003e\n\u003cli\u003eFeatures \u003cstrong\u003edomestic OSY resilient seated gate valves\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInline serviceable assembly\u003c\/strong\u003e requires no special tools.\u003c\/li\u003e\n\u003cli\u003eReversible and replaceable discs with captured modular spring and clapper check assemblies.\u003c\/li\u003e\n\u003cli\u003eField replaceable seats.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eAn add-on connection kit is required to activate the flood sensor for communication; without it, the flood sensor is a passive component. Watts® is not responsible for alert failures due to connectivity issues, power outages, or improper installation. Always comply with all required installation instructions, codes, and regulations.\u003c\/em\u003e\u003c\/p\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796695064853,"sku":"F8007383","price":39229.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/179382.jpg?v=1772726972"},{"product_id":"8-lf880wz-dnrs-rp-fs","title":"8 LF880WZ-DNRS RP-FS","description":"\u003cp\u003eThis 8 inch lead free \u003cstrong\u003eMasterSeries® LF880WZ\u003c\/strong\u003e configurable reduced pressure zone backflow preventer assembly protects against \u003cstrong\u003ehigh hazard (toxic) fluids\u003c\/strong\u003e in water services to industrial installations and applications. It features a \u003cstrong\u003elonger gate-to-gate length\u003c\/strong\u003e for direct drop-in replacement of competitor’s Z-pattern valves.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAdvanced Protection \u0026amp; Durability\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIntegrated \u003cstrong\u003eflood sensor\u003c\/strong\u003e with \u003cstrong\u003eSentryPlus Alert® technology\u003c\/strong\u003e detects excessive water discharges from the relief valve.\u003c\/li\u003e\n\u003cli\u003eSensor can be activated by an add-on connection kit (sold separately) for alerts via BMS, cellular communication, or Sensor Control Monitor (BAS via RS-485 Modbus or Nexa® platform via Wi-Fi).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmorTek® epoxy coating\u003c\/strong\u003e applied to internal and external surfaces of the \u003cstrong\u003eductile iron body\u003c\/strong\u003e provides advanced corrosion protection.\u003c\/li\u003e\n\u003cli\u003eFeatures \u003cstrong\u003estainless steel relief valve seat\u003c\/strong\u003e and \u003cstrong\u003estainless steel check components\u003c\/strong\u003e for maximum performance and extended durability.\u003c\/li\u003e\n\u003cli\u003eEquipped with \u003cstrong\u003edomestic NRS (Non-Rising Stem) resilient seated gate valves\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDesign \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInline serviceable assembly\u003c\/strong\u003e requires no special tools for maintenance.\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003ecaptured modular spring assembly\u003c\/strong\u003e, clapper check assembly, reversible and replaceable discs, and field replaceable seats.\u003c\/li\u003e\n\u003cli\u003eDesigned for flexible installation in either \u003cstrong\u003eN-pattern\u003c\/strong\u003e (horizontal) or \u003cstrong\u003eZ-pattern\u003c\/strong\u003e (vertical up) configurations.\u003c\/li\u003e\n\u003cli\u003eFeatures a \u003cstrong\u003emodular and repairable pressure differential relief valve\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eInstallation must be performed by a trained product installer. Always read all installation instructions and product safety information, and inquire with governing authorities for local installation requirements.\u003c\/em\u003e\u003c\/p\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796700176661,"sku":"F8007382","price":36778.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/179572.jpg?v=1772727129"},{"product_id":"8-lf880w-dnrs-rp-fs","title":"8 LF880W-DNRS RP-FS","description":"","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796822958357,"sku":"F8007370","price":36778.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/183934.jpg?v=1772730927"}],"url":"https:\/\/www.backflowpreventer.com\/collections\/backflow-devices-febco-rpz-reduced-pressure-zone-assemblies-8-880w-series.oembed","provider":"Water Specialties Company","version":"1.0","type":"link"}