{"title":"Backflow Devices - Watts - DCVA - Double Check Valve Assemblies - 1\" - SS007 Series","description":null,"products":[{"product_id":"1-ss007m1-qt-fz","title":"1 SS007M1-QT-FZ","description":"\u003cp\u003eThis 1 inch double check valve backflow preventer assembly is designed to prevent the backflow of polluted water from entering into the potable water supply due to backsiphonage and\/or backpressure in accordance with national plumbing codes and water authority requirements. It is ideal for protection in \u003cstrong\u003econtinuous pressure piping applications\u003c\/strong\u003e and at \u003cstrong\u003ecross-connections identified as non-health hazards\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eWARNING: The freeze sensor solely provides alerts about a possible freeze event and cannot prevent a freeze event from occurring. User action is required to prevent freeze conditions from causing product and\/or property damage.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConstruction \u0026amp; Design\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFeatures \u003cstrong\u003einvestment cast 316 stainless steel\u003c\/strong\u003e for superior corrosion resistance.\u003c\/li\u003e\n\u003cli\u003eAll \u003cstrong\u003ewetted valve components\u003c\/strong\u003e (test cocks, ball valve shutoffs, pipe nipples, body and cover, and check modules) are made from \u003cstrong\u003eLead Free stainless steel\u003c\/strong\u003e or plastic construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBolted-on, top-entry, single access cover\u003c\/strong\u003e allows for ease of maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular check construction\u003c\/strong\u003e with nonreversible checks and captured springs for simplified servicing.\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003etop-mounted, vandal-resistant EZ-TC-SS test cocks\u003c\/strong\u003e requiring no tools or fittings for easy access during testing.\u003c\/li\u003e\n\u003cli\u003eStainless steel test cocks include \u003cstrong\u003edust covers\u003c\/strong\u003e to protect threads from dirt, dust, and insects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaceable check valve seats\u003c\/strong\u003e require no special tools.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue line sized check modules\u003c\/strong\u003e reduce fouling from dirt and debris.\u003c\/li\u003e\n\u003cli\u003eIncorporates a protective \u003cstrong\u003estainless steel Wye strainer\u003c\/strong\u003e with a 20 mesh screen.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFreeze Sensor Technology\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEquipped with a \u003cstrong\u003efreeze sensor\u003c\/strong\u003e for use with SentryPlus Alert® technology to monitor temperature and alert facility personnel when freeze conditions can cause damage.\u003c\/li\u003e\n\u003cli\u003eSensor provides flexibility in locating a measuring tool at or near any water-carrying outdoor installation vulnerable to freezing.\u003c\/li\u003e\n\u003cli\u003eAn add-on \u003cstrong\u003econnection kit (sold separately)\u003c\/strong\u003e is required to activate the freeze sensor's monitoring system and trigger alerts for low and freezing temperatures.\u003c\/li\u003e\n\u003cli\u003eBuilt-in \u003cstrong\u003eWi-Fi function\u003c\/strong\u003e communicates freeze alerts directly to the user (with connection kit), eliminating the need for a third-party controller.\u003c\/li\u003e\n\u003cli\u003eSwitched output relay can augment BMS or irrigation management systems with reinforced control of sprinkler systems.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796831117589,"sku":"T062692","price":3149.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/184124.jpg?v=1772731177"},{"product_id":"1-ss007m1-qt-s-fz","title":"1 SS007M1-QT-S-FZ","description":"\u003cp\u003eThis 1 inch double check valve backflow preventer assembly is designed to prevent the backflow of polluted water from entering into the potable water supply due to backsiphonage and or backpressure in accordance with national plumbing codes and water authority requirements. It is ideal for protection in continuous pressure piping applications and at cross-connections identified as non-health hazards and for contaminants at the service line entrance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFeatures a durable \u003cstrong\u003estainless steel body construction\u003c\/strong\u003e, quarter turn ball valve shutoffs, and a top mounted test cocks.\u003c\/li\u003e\n\u003cli\u003eIncludes two \u003cstrong\u003ein-line independent positive seating check modules\u003c\/strong\u003e with captured springs and replaceable check discs and seats for reliable operation.\u003c\/li\u003e\n\u003cli\u003eA \u003cstrong\u003ebronze strainer\u003c\/strong\u003e is integrated into the assembly.\u003c\/li\u003e\n\u003cli\u003eComes with a \u003cstrong\u003efreeze sensor\u003c\/strong\u003e for use with \u003cstrong\u003eSentryPlus Alert® technology\u003c\/strong\u003e to signal facility personnel when temperature nears and reaches the freezing point.\u003c\/li\u003e\n\u003cli\u003eFreeze alerts are available with an \u003cstrong\u003eadd-on connection kit\u003c\/strong\u003e (sold separately) for Wi-Fi networks, building management systems (BMS), and irrigation management systems (IMS).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular, compact design\u003c\/strong\u003e facilitates easy maintenance with a single access cover for in-line repairs.\u003c\/li\u003e\n\u003cli\u003eOffers \u003cstrong\u003elow pressure drop\u003c\/strong\u003e and requires no special tools for servicing.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eA WARNING: The freeze sensor solely provides alerts about a possible freeze event and cannot prevent a freeze event from occurring. User action is required to prevent freeze conditions from causing product and\/or property damage.\u003c\/em\u003e\u003c\/p\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796836458773,"sku":"T062709","price":3591.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/184245.jpg?v=1772731386"}],"url":"https:\/\/www.backflowpreventer.com\/collections\/backflow-devices-watts-dcva-double-check-valve-assemblies-1-ss007-series.oembed","provider":"Water Specialties Company","version":"1.0","type":"link"}