{"title":"Backflow Devices - Watts - RPZ - Reduced Pressure Zone Assemblies - 1\" - SS009 Series","description":null,"products":[{"product_id":"1-ss009-qt-s-fs","title":"1 SS009-QT-S-FS","description":"\u003cp\u003eThis \u003cstrong\u003e1 inch Watts SS009 series stainless steel reduced pressure zone backflow preventer assembly\u003c\/strong\u003e is designed to prevent the flow of polluted water from entering the potable water supply due to backsiphonage and\/or backpressure.\u003c\/p\u003e\u003cp\u003eIt is ideal for typical applications in \u003cstrong\u003eindustrial plants\u003c\/strong\u003e, \u003cstrong\u003emedical diagnostic equipment\u003c\/strong\u003e, \u003cstrong\u003ereverse osmosis systems\u003c\/strong\u003e, \u003cstrong\u003ecarbonated beverage machines\u003c\/strong\u003e, \u003cstrong\u003ebrewing distilleries\u003c\/strong\u003e, \u003cstrong\u003epaper and pulp industries\u003c\/strong\u003e, \u003cstrong\u003echemical plants\u003c\/strong\u003e, and \u003cstrong\u003eaggressive atmospheres\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eThis assembly incorporates a \u003cstrong\u003eflood sensor with SentryPlus Alert technology\u003c\/strong\u003e to detect excessive water discharges from the relief valve.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConstruction \u0026amp; Design\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInvestment Cast 316 Stainless Steel Assembly\u003c\/strong\u003e for superior \u003cstrong\u003ecorrosion resistance\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eAll wetted valve components, including test cocks, ball valve shutoffs, and pipe nipples, are made from \u003cstrong\u003eLead Free* stainless steel or plastic\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eBolted on, \u003cstrong\u003etop entry single access cover\u003c\/strong\u003e for ease of maintenance and servicing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular check construction\u003c\/strong\u003e features \u003cstrong\u003enon-reversible checks\u003c\/strong\u003e with captured springs for simplified servicing.\u003c\/li\u003e\n\u003cli\u003eTrue line sized check modules open further to reduce fouling problems caused by dirt and debris.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck and relief valve seats are replaceable\u003c\/strong\u003e without special tools.\u003c\/li\u003e\n\u003cli\u003eDesigned with an \u003cstrong\u003einternal relief valve\u003c\/strong\u003e for both right and left-hand installations and reduced installation clearances.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eComponents \u0026amp; Connections\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFeatures \u003cstrong\u003eNPT inlet and outlet end connections\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIncludes a \u003cstrong\u003eprotective stainless steel wye strainer\u003c\/strong\u003e with a 20 mesh screen.\u003c\/li\u003e\n\u003cli\u003eEquipped with \u003cstrong\u003equarter-turn full port resilient seated ball valve shutoffs\u003c\/strong\u003e with \u003cstrong\u003etee handles\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop-mounted, vandal-resistant test cocks\u003c\/strong\u003e with covers provide easy access for testing.\u003c\/li\u003e\n\u003cli\u003eComposed of two in-line independent check valves, captured springs, replaceable check seats, and a hydraulically operated differential pressure internal relief valve.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFlood Detection\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIncorporates a \u003cstrong\u003eflood sensor\u003c\/strong\u003e on the relief valve for detection of excessive water discharge.\u003c\/li\u003e\n\u003cli\u003eThe flood sensor, when activated through an \u003cstrong\u003eadd-on sensor connection kit\u003c\/strong\u003e (available separately for BMS or cellular communications), can send an alert to notify users of potential flooding.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cem\u003e\u003cp\u003e\u003cstrong\u003eWarning:\u003c\/strong\u003e Use of the flood sensor is a notification aid and does not replace the need to comply with all required instructions, codes, and regulations related to installation, operation, and maintenance of this product, including the necessity of providing proper drainage in the event of a discharge. Watts is not responsible for the failure of alerts due to connectivity issues, power outages, or improper installation.\u003c\/p\u003e\n\u003cp\u003e*The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight.\u003c\/p\u003e\u003c\/em\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796758438165,"sku":"88004050","price":6891.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/185078.jpg?v=1772813582"},{"product_id":"1-ss009-qt-fs","title":"1 SS009-QT-FS","description":"\u003cp\u003eThis 1 inch Watts Series SS009 Reduced Pressure Zone Backflow Preventer Assembly is designed to prevent the flow of polluted water from entering into the potable water supply due to backsiphonage and\/or backpressure. It is ideal for typical applications found in industrial plants, medical diagnostic equipment, reverse osmosis systems, carbonated beverage machines, brewing distillers, paper and pulp industries, chemical plants, and aggressive atmospheres.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInvestment Cast 316 Stainless Steel\u003c\/strong\u003e assembly for superior \u003cstrong\u003ecorrosion resistance\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSentryPlus Alert flood sensor\u003c\/strong\u003e technology to detect excessive water discharges from the relief valve\u003c\/li\u003e\n\u003cli\u003eAlert features available with an \u003cstrong\u003eadd-on sensor connection kit\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAll wetted valve components (test cocks, ball valve shutoffs, pipe nipples) made from \u003cstrong\u003eLead Free* stainless steel\u003c\/strong\u003e or plastic\u003c\/li\u003e\n\u003cli\u003eBolted on, top entry single access cover for \u003cstrong\u003eease of maintenance\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eModular check construction featuring non-reversible checks with captured springs for \u003cstrong\u003esimplified servicing\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eTop-mounted, \u003cstrong\u003evandal-resistant test cocks\u003c\/strong\u003e with covers for testing\u003c\/li\u003e\n\u003cli\u003eTrue line sized check modules open further for dirt and debris to pass through the valve, reducing fouling problems\u003c\/li\u003e\n\u003cli\u003eCheck and relief valve seat \u003cstrong\u003ereplaceable without special tools\u003c\/strong\u003e for economical repair\u003c\/li\u003e\n\u003cli\u003eInternal relief valve for reduced installation clearances, suitable for right and left hand installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuarter-turn full port resilient seated ball valve shutoffs\u003c\/strong\u003e with 304 stainless steel tee handles and PTFE seat blowout proof 304 stainless steel stems\u003c\/li\u003e\n\u003cli\u003eProtective \u003cstrong\u003estainless steel wye strainer\u003c\/strong\u003e with a 20 mesh screen\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMaterials\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBody: \u003cstrong\u003e316 stainless steel\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDisc and Relief Valve: \u003cstrong\u003eSilicone rubber\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCheck Seats: \u003cstrong\u003eReplaceable polymer\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRelief Valve Seat: \u003cstrong\u003eRemovable relief valve seats\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCover Bolts: \u003cstrong\u003eStainless steel\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eShutoff Valve Stem: \u003cstrong\u003e304 Stainless Steel\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eShutoff Valve Handle: \u003cstrong\u003e304 Stainless Steel Tee Handle\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eStrainer: \u003cstrong\u003eStainless Steel\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eAn add-on connection kit (Watts RP\/IS-009) is required to activate the flood sensor's alert features; without it, the sensor is a passive component that has no communication with any any other device.\u003c\/em\u003e\u003c\/p\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796772757781,"sku":"88004044","price":5162.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/182194.jpg?v=1772729301"}],"url":"https:\/\/www.backflowpreventer.com\/collections\/backflow-devices-watts-rpz-reduced-pressure-zone-assemblies-1-ss009-series.oembed","provider":"Water Specialties Company","version":"1.0","type":"link"}