{"title":"Backflow Devices - Watts - RPZ - Reduced Pressure Zone Assemblies - 6\"","description":null,"products":[{"product_id":"6-957-dnrs","title":"6 957-DNRS","description":"\u003cp\u003eThe 6 inch Watts Series 957 Reduced Pressure Zone (RPZ) assembly backflow preventer with \u003cstrong\u003edomestic non-rising stem (NRS) shutoff valves\u003c\/strong\u003e is designed to protect potable water systems from contamination caused by backsiphonage or backpressure, meeting national plumbing codes and water authority requirements. This assembly is approved for horizontal installation and is ideal for continuous pressure piping applications and cross-connections identified as health hazards.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtremely compact design\u003c\/strong\u003e, significantly lighter than traditional designs\u003c\/li\u003e\n\u003cli\u003eHousing and sleeve constructed from \u003cstrong\u003e304 (Schedule 40) stainless steel\u003c\/strong\u003e for durability\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003edomestic non-rising stem gate valves\u003c\/strong\u003e for shutoff\u003c\/li\u003e\n\u003cli\u003ePatented \u003cstrong\u003etorsion spring check valves\u003c\/strong\u003e provide lowest pressure loss\u003c\/li\u003e\n\u003cli\u003eFeatures a \u003cstrong\u003ecorrosive-resistant stainless steel bottom-mounted pressure relief valve\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003eunmatched ease of serviceability\u003c\/strong\u003e with no special tools required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroove fittings\u003c\/strong\u003e allow integral pipeline adjustment\u003c\/li\u003e\n\u003cli\u003eEquipped with \u003cstrong\u003eball valve type test cocks\u003c\/strong\u003e for easy testing\u003c\/li\u003e\n\u003cli\u003eWetted surface contains less than \u003cstrong\u003e0.25% lead by weight\u003c\/strong\u003e, making it lead-free\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796738023701,"sku":"0792322","price":27288.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/180774.jpg?v=1772728149"},{"product_id":"6-957z-bfg-fs","title":"6 957Z-BFG-FS","description":"\u003cp\u003eThis 6 inch reduced pressure zone assembly backflow preventer helps protect the potable water system from contamination by preventing the reverse flow of liquids due to \u003cstrong\u003ebackpressure\u003c\/strong\u003e or \u003cstrong\u003ebacksiphonage\u003c\/strong\u003e, especially in health hazard applications. Its extremely \u003cstrong\u003ecompact design\u003c\/strong\u003e, \u003cstrong\u003e304 (Schedule 40) stainless steel\u003c\/strong\u003e housing and sleeve, and grooved gear operated butterfly valves with tamper switch make it a reliable and serviceable solution for water system protection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConstruction \u0026amp; Design\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFeatures a \u003cstrong\u003e304 (Schedule 40) stainless steel housing and sleeve\u003c\/strong\u003e for durability.\u003c\/li\u003e\n\u003cli\u003eEquipped with two independent \u003cstrong\u003etorsion spring check modules\u003c\/strong\u003e with \u003cstrong\u003ereplaceable elastomer discs\u003c\/strong\u003e (EPDM, silicone, or Buna-N).\u003c\/li\u003e\n\u003cli\u003eIncludes a \u003cstrong\u003ebottom mounted cast stainless steel relief valve\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrooved gear operated butterfly valves with tamper switch\u003c\/strong\u003e for shutoff and monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Free* bronze body\u003c\/strong\u003e for test cocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroove couplings\u003c\/strong\u003e facilitate ease of installation and pipe alignment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtremely compact design\u003c\/strong\u003e, up to 70% lighter than traditional designs, allowing for smaller enclosures.\u003c\/li\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003eZ-pattern orientation\u003c\/strong\u003e and approved for horizontal installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFlood Detection \u0026amp; Alerts\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIntegrated \u003cstrong\u003eflood sensor with SentryPlus Alert® technology\u003c\/strong\u003e to detect excessive water discharges from the relief valve.\u003c\/li\u003e\n\u003cli\u003eWhen paired with an add-on connection kit, the sensor activates to relay alerts for potential flooding events to facility personnel, helping to limit damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection kit options\u003c\/strong\u003e include compatibility with BMS, cellular communication, and the Sensor Control Monitor for integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e An add-on connection kit is required to activate the flood sensor for communication; without it, the sensor is a passive component. The flood sensor does not replace the need for proper drainage or compliance with all installation, operation, and maintenance instructions and codes.\u003c\/em\u003e\u003c\/p\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796757389589,"sku":"F111787","price":23670.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/181500.jpg?v=1772728732"},{"product_id":"6-lf909-dosy-fs","title":"6 LF909-DOSY-FS","description":"\u003cp\u003eThis 6 inch lead free reduced pressure zone backflow preventer assembly is designed to prevent the reverse flow of polluted water from entering the potable water supply due to backsiphonage and backpressure. It is ideal for protection in continuous pressure piping applications and at cross-connections identified as health hazards.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConstruction \u0026amp; Materials\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFeatures an \u003cstrong\u003eepoxy coated cast iron body\u003c\/strong\u003e, domestic outside stem and yoke resilient seated gate valves, captured spring check valves, replaceable seats, and top mounted test cocks.\u003c\/li\u003e\n\u003cli\u003eThe coating utilizes \u003cstrong\u003eArmorTek®\u003c\/strong\u003e, a patented 3-part advanced epoxy coating system engineered to limit both \u003cstrong\u003emicrobial induced corrosion (MIC)\u003c\/strong\u003e and exposed metal substrate corrosion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Free*\u003c\/strong\u003e construction complies with current installation requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFlood Sensor \u0026amp; Alerts\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIncludes a \u003cstrong\u003eflood sensor with SentryPlus Alert® technology\u003c\/strong\u003e to detect excessive water discharges from the relief valve.\u003c\/li\u003e\n\u003cli\u003eWhen paired with an add-on connection kit, the sensor activates to relay alerts for potential flooding events.\u003c\/li\u003e\n\u003cli\u003eConnection kit options include \u003cstrong\u003eBMS\u003c\/strong\u003e, \u003cstrong\u003ecellular communication\u003c\/strong\u003e, and the \u003cstrong\u003eSensor Control Monitor\u003c\/strong\u003e for integration with \u003cstrong\u003eBAS via RS-485 Modbus\u003c\/strong\u003e or the \u003cstrong\u003eNexa® platform through Wi-Fi\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eThe sensor is installed on the assembly exterior and does not alter assembly functions or certifications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePerformance \u0026amp; Design\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eField reversible pressure differential relief valve\u003c\/strong\u003e with a unique \u003cstrong\u003eair-in\/water-out design\u003c\/strong\u003e provides maximum capacity during emergency conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaceable seats\u003c\/strong\u003e and \u003cstrong\u003estainless steel internal parts\u003c\/strong\u003e for ease of maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo special tools required\u003c\/strong\u003e for servicing.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cem\u003eNote: An add-on connection kit is required to activate the flood sensor. Without the connection kit, the sensor is a passive component with no communication.\u003c\/em\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796759748885,"sku":"88009318","price":30434.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/181602.jpg?v=1772728815"},{"product_id":"6-957-bfg-fs","title":"6 957-BFG-FS","description":"\u003cp\u003eThe WATTS 6 inch Series 957 Reduced Pressure Zone (RPZ) backflow preventer protects potable water systems from contamination caused by \u003cstrong\u003ebacksiphonage\u003c\/strong\u003e or \u003cstrong\u003ebackpressure\u003c\/strong\u003e, particularly in health hazard applications. This compact assembly features \u003cstrong\u003eUL Classified\u003c\/strong\u003e and \u003cstrong\u003eFM Approved\u003c\/strong\u003e grooved gear operated butterfly valves with tamper switches and an integrated flood sensor.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDesign and Construction\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFeatures a \u003cstrong\u003e304 (Schedule 40) stainless steel housing and sleeve\u003c\/strong\u003e for robust durability.\u003c\/li\u003e\n\u003cli\u003eEquipped with \u003cstrong\u003epatented torsion spring checks\u003c\/strong\u003e designed for lowest pressure loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroove fittings\u003c\/strong\u003e facilitate integral pipeline adjustment and ease of installation.\u003c\/li\u003e\n\u003cli\u003eDesigned for unmatched ease of serviceability and is up to \u003cstrong\u003e70% lighter\u003c\/strong\u003e than traditional designs.\u003c\/li\u003e\n\u003cli\u003eIncludes a corrosive-resistant, \u003cstrong\u003ebottom-mounted cast stainless steel relief valve\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFlood Detection and Alerts\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIncorporates a \u003cstrong\u003eflood sensor with SentryPlus Alert® technology\u003c\/strong\u003e to detect excessive water discharges from the relief valve.\u003c\/li\u003e\n\u003cli\u003eWhen paired with an \u003cstrong\u003eadd-on sensor connection kit\u003c\/strong\u003e (sold separately), the flood sensor activates to relay alerts for potential flooding events.\u003c\/li\u003e\n\u003cli\u003eConnection kit options include compatibility with \u003cstrong\u003eBMS\u003c\/strong\u003e, \u003cstrong\u003ecellular communication\u003c\/strong\u003e, and the \u003cstrong\u003eSensor Control Monitor\u003c\/strong\u003e for integration with \u003cstrong\u003eBAS via RS-485 Modbus\u003c\/strong\u003e or the \u003cstrong\u003eNexa® platform through Wi-Fi\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eA connection kit is required to activate the flood sensor's communication features; without it, the sensor operates as a passive component.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796764467477,"sku":"F111789","price":15177.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/181818.jpg?v=1772728988"},{"product_id":"6-957-osy-fxg-fs","title":"6 957-OSY-FxG-FS","description":"\u003cp\u003eThis \u003cstrong\u003e6 inch\u003c\/strong\u003e Watts Series 957 Reduced Pressure Zone (RPZ) backflow preventer protects potable water systems from contamination due to \u003cstrong\u003ebackpressure or backsiphonage\u003c\/strong\u003e, addressing potential health hazards. It is designed for horizontal installation and features an extremely compact and lightweight design compared to traditional models.\u003c\/p\u003e\u003cp\u003eThe assembly includes a \u003cstrong\u003eflood sensor with SentryPlus Alert® technology\u003c\/strong\u003e to detect excessive water discharges from the relief valve.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConstruction \u0026amp; Design\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e304 (Schedule 40) stainless steel\u003c\/strong\u003e housing and sleeve\u003c\/li\u003e\n\u003cli\u003eFeatures \u003cstrong\u003etorsion spring check valves\u003c\/strong\u003e and a \u003cstrong\u003ecorrosive resistant stainless steel bottom mounted pressure relief valve\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL and FM approved outside stem and yoke resilient seated gate valves\u003c\/strong\u003e for shutoff\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlanged inlet gate connection\u003c\/strong\u003e and \u003cstrong\u003egrooved outlet gate connection\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroove couplings\u003c\/strong\u003e for ease of installation and pipeline alignment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaceable check disc rubber\u003c\/strong\u003e for simplified maintenance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact design\u003c\/strong\u003e, making it significantly lighter than traditional assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFlood Sensor Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSentryPlus Alert® technology\u003c\/strong\u003e detects continuous discharge from the relief valve\u003c\/li\u003e\n\u003cli\u003eWhen paired with an add-on connection kit (sold separately), the sensor relays alerts for potential flooding events\u003c\/li\u003e\n\u003cli\u003eCompatible with BMS and cellular communication via connection kits\u003c\/li\u003e\n\u003cli\u003eIntegration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi is possible with the Sensor Control Monitor connection kit\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796766368021,"sku":"F191640","price":14694.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/181921.jpg?v=1772729070"},{"product_id":"6-lf909-osy-nyc-fs","title":"6 LF909-OSY NYC-FS","description":"\u003cp\u003eThis 6 inch \u003cstrong\u003eLead Free Reduced Pressure Zone Backflow Preventer Assembly\u003c\/strong\u003e with \u003cstrong\u003eOSY (Outside Stem \u0026amp; Yoke) shutoff valves\u003c\/strong\u003e is designed to prevent the reverse flow of polluted water from entering into the potable water supply due to backsiphonage or backpressure.\u003c\/p\u003e\u003cp\u003eThis assembly is specifically designed for \u003cstrong\u003eNYC installations\u003c\/strong\u003e, featuring pre-drilled bolts and a discharge restrictor plate. It also incorporates a \u003cstrong\u003eflood sensor with SentryPlus Alert® technology\u003c\/strong\u003e to detect continuous discharge from the relief valve, providing enhanced monitoring capabilities.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Free\u003c\/strong\u003e construction ensures compliance with reduced lead content requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmorTek® coating technology\u003c\/strong\u003e on iron components resists electrochemical and microbial-induced corrosion internally and externally.\u003c\/li\u003e\n\u003cli\u003eFeatures a \u003cstrong\u003eflood sensor with SentryPlus Alert® technology\u003c\/strong\u003e to detect continuous discharge from the relief valve.\u003c\/li\u003e\n\u003cli\u003eIncludes an add-on sensor connection kit for extended flood monitoring (compatible with BMS, cellular, or Sensor Control Monitor for BAS integration via RS-485 Modbus or Nexa® Wi-Fi platform).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaceable seats\u003c\/strong\u003e and \u003cstrong\u003estainless steel internal parts\u003c\/strong\u003e for durability and easy maintenance.\u003c\/li\u003e\n\u003cli\u003eCaptured \u003cstrong\u003espring check assemblies\u003c\/strong\u003e and fused \u003cstrong\u003eepoxy coated and lined checks\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField reversible pressure differential relief valve\u003c\/strong\u003e design provides maximum capacity.\u003c\/li\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003eNYC installations\u003c\/strong\u003e with pre-drilled 304 stainless steel bolts\/nuts (1\/4 inch axially drilled holes) and a discharge restrictor plate.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConstruction \u0026amp; Materials\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEpoxy coated cast iron body\u003c\/strong\u003e for robust protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOSY resilient seated gate valves\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCast iron relief valve body\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel seat and trim\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Free* copper silicon alloy test cocks\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796770529557,"sku":"88009410","price":36517.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/182104.jpg?v=1772729227"},{"product_id":"6-957n-bfg-fs","title":"6 957N-BFG-FS","description":"\u003cp\u003eThe Watts Series 957 6 inch Reduced Pressure Zone assembly backflow preventer provides protection to potable water systems from contamination due to backpressure or backsiphonage, typically used in health hazard applications.\u003c\/p\u003e\u003cp\u003eThis extremely compact assembly is designed for horizontal N pattern installation and includes a flood sensor with \u003cstrong\u003eSentryPlus Alert technology\u003c\/strong\u003e to detect continuous discharge from the relief valve.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFeatures a \u003cstrong\u003eflood sensor\u003c\/strong\u003e with SentryPlus Alert technology to detect continuous discharge from the relief valve\u003c\/li\u003e\n\u003cli\u003eAdd-on sensor connection kit allows for extended flood monitoring and integration with Building Management Systems (BMS), cellular communication, or Nexa platform via Wi-Fi\u003c\/li\u003e\n\u003cli\u003eConstructed with a \u003cstrong\u003e304 (Schedule 40) stainless steel housing and sleeve\u003c\/strong\u003e for durability\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003eUL Classified and FM Approved grooved gear operated butterfly valve shutoffs with tamper switch\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eEquipped with \u003cstrong\u003ereplaceable check disc rubber\u003c\/strong\u003e and a \u003cstrong\u003ebottom mounted cast stainless steel relief valve\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtremely compact design\u003c\/strong\u003e allows for use in smaller enclosures and is 70% lighter than traditional designs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroove couplings\u003c\/strong\u003e facilitate ease of installation and pipe alignment\u003c\/li\u003e\n\u003cli\u003ePatented torsion spring checks provide lowest pressure loss and unmatched ease of serviceability\u003c\/li\u003e\n\u003cli\u003eEquipped with test cocks\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796770922773,"sku":"F111783","price":23668.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/182115.jpg?v=1772729237"},{"product_id":"6-957-nrs-fs","title":"6 957-NRS-FS","description":"\u003cp\u003eThis 6 inch \u003cstrong\u003eWatts Series 957 Reduced Pressure Zone (RPZ) assembly backflow preventer\u003c\/strong\u003e protects potable water systems from contamination due to backpressure or backsiphonage, particularly in health hazard applications. Its extremely compact and lightweight design allows for horizontal installation.\u003c\/p\u003e\u003cp\u003eThe assembly includes a \u003cstrong\u003eflood sensor with SentryPlus Alert® technology\u003c\/strong\u003e to detect continuous water discharges from the relief valve. When paired with an add-on connection kit, the sensor relays alerts to facility personnel for corrective action, helping to limit flooding and costly damage.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConstruction \u0026amp; Design\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFeatures a \u003cstrong\u003e304 (Schedule 40) stainless steel housing and sleeve\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eEquipped with \u003cstrong\u003eUL Classified and FM Approved non-rising stem (NRS) resilient seated gate valves\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eDesigned with \u003cstrong\u003epatented torsion spring check valves\u003c\/strong\u003e that provide lowest pressure loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroove fittings\u003c\/strong\u003e facilitate integral pipeline adjustment and ease of installation.\u003c\/li\u003e\n\u003cli\u003eIncludes a corrosive-resistant, \u003cstrong\u003ebottom-mounted cast stainless steel relief valve\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaceable check disc rubber\u003c\/strong\u003e for simplified maintenance.\u003c\/li\u003e\n\u003cli\u003e70% lighter than traditional designs, offering an extremely compact footprint.\u003c\/li\u003e\n\u003cli\u003eLead-free* bronze body components, such as the \u003cstrong\u003etest cocks\u003c\/strong\u003e, ensure the wetted surface contains less than 0.25% lead by weight.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFlood Sensor Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSentryPlus Alert® technology\u003c\/strong\u003e detects excessive water discharges from the relief valve.\u003c\/li\u003e\n\u003cli\u003eRequires an \u003cstrong\u003eadd-on connection kit\u003c\/strong\u003e to activate flood alerts and enable communication.\u003c\/li\u003e\n\u003cli\u003eCompatible with \u003cstrong\u003eBuilding Management Systems (BMS)\u003c\/strong\u003e and \u003cstrong\u003ecellular network communication\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eCan integrate with the Sensor Control Monitor for alerts via \u003cstrong\u003eBAS (RS-485 Modbus)\u003c\/strong\u003e or the \u003cstrong\u003eNexa® platform through Wi-Fi\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796773216533,"sku":"F111605","price":13828.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/182219.jpg?v=1772729321"},{"product_id":"6-957n-osy-fs","title":"6 957N-OSY-FS","description":"\u003cp\u003eThe Watts Series 957 6 inch Reduced Pressure Zone (RPZ) backflow preventer provides critical protection for potable water systems from contamination due to \u003cstrong\u003ebacksiphonage\u003c\/strong\u003e or \u003cstrong\u003ebackpressure\u003c\/strong\u003e in health hazard applications. This compact and lightweight assembly features \u003cstrong\u003eOSY shutoff valves\u003c\/strong\u003e and an \u003cstrong\u003eN pattern orientation\u003c\/strong\u003e, approved for horizontal installation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEquipped with a \u003cstrong\u003eflood sensor\u003c\/strong\u003e featuring SentryPlus Alert technology to detect continuous discharge from the relief valve.\u003c\/li\u003e\n\u003cli\u003eHoused in a durable \u003cstrong\u003e304 (Schedule 40) stainless steel\u003c\/strong\u003e body and sleeve.\u003c\/li\u003e\n\u003cli\u003eFeatures \u003cstrong\u003eUL and FM Approved outside stem and yoke (OSY) resilient seated gate valves\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003ereplaceable check disc rubber\u003c\/strong\u003e and a \u003cstrong\u003ebottom mounted cast stainless steel relief valve\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eDesigned with \u003cstrong\u003egroove couplings\u003c\/strong\u003e for simplified installation and pipeline adjustment.\u003c\/li\u003e\n\u003cli\u003ePatented \u003cstrong\u003etorsion spring checks\u003c\/strong\u003e for lowest pressure loss and unmatched ease of serviceability.\u003c\/li\u003e\n\u003cli\u003eOverall compact design is \u003cstrong\u003e70% lighter\u003c\/strong\u003e than traditional designs, allowing for smaller enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFlood Sensor Technology\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThe integrated flood sensor is designed to detect excessive water discharges from the relief valve, relaying a signal for corrective action and limiting potential flooding.\u003c\/li\u003e\n\u003cli\u003eAn \u003cstrong\u003eadd-on sensor connection kit is required\u003c\/strong\u003e to activate flood alerts. Without this kit, the sensor is a passive component.\u003c\/li\u003e\n\u003cli\u003eCompatible with \u003cstrong\u003eBMS (Building Management Systems)\u003c\/strong\u003e and \u003cstrong\u003ecellular network communication\u003c\/strong\u003e via an add-on connection kit.\u003c\/li\u003e\n\u003cli\u003eWith the Sensor Control Monitor, it delivers maintenance alerts to BAS via \u003cstrong\u003eRS-485 Modbus\u003c\/strong\u003e or the Nexa platform by \u003cstrong\u003eWi-Fi connectivity\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eUse of the flood sensor does not replace the need to comply with all required instructions, codes, and regulations related to installation, operation, and maintenance of this product, including providing proper drainage in the event of a discharge.\u003c\/em\u003e\u003c\/p\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796774691093,"sku":"F111593","price":21520.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/182294.jpg?v=1772729390"},{"product_id":"6-lf909-dnrs-fs","title":"6 LF909-DNRS-FS","description":"\u003cp\u003eThis 6 inch lead free reduced pressure zone backflow preventer assembly prevents the reverse flow of polluted water from entering into the potable water supply due to \u003cstrong\u003ebacksiphonage\u003c\/strong\u003e and\/or \u003cstrong\u003ebackpressure\u003c\/strong\u003e. It is designed for protection in continuous pressure piping applications and at cross-connections identified as health hazards.\u003c\/p\u003e\u003cp\u003eThe assembly features an \u003cstrong\u003eepoxy coated cast iron body\u003c\/strong\u003e, domestic \u003cstrong\u003enon-rising stem resilient seated gate valves\u003c\/strong\u003e, captured spring check valves, replaceable seats, top mounted test cocks, and a field reversible pressure differential relief valve. The coating utilizes \u003cstrong\u003eArmorTek®\u003c\/strong\u003e, a patented 3-part advanced epoxy system engineered to limit both microbial induced (MIC) and exposed metal substrate corrosion.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFlood Sensor Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIncludes a \u003cstrong\u003eflood sensor with SentryPlus Alert® technology\u003c\/strong\u003e to detect excessive water discharges from the relief valve.\u003c\/li\u003e\n\u003cli\u003eWhen paired with an \u003cstrong\u003eadd-on connection kit\u003c\/strong\u003e, the sensor is activated to relay alerts for potential flooding events to facility personnel.\u003c\/li\u003e\n\u003cli\u003eConnection kit options include \u003cstrong\u003eBMS\u003c\/strong\u003e, \u003cstrong\u003ecellular communication\u003c\/strong\u003e, and the \u003cstrong\u003eSensor Control Monitor\u003c\/strong\u003e which enables integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eUse of the flood sensor does not replace the need to comply with all required instructions, codes, and regulations related to installation, operation, and maintenance, including the need to provide proper drainage in the event of a discharge. Watts is not responsible for the failure of alerts due to connectivity issues, power outages, or improper installation.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAdditional Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaceable seats\u003c\/strong\u003e and \u003cstrong\u003estainless steel internal parts\u003c\/strong\u003e for easy maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCaptured spring check assemblies\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFused epoxy coated and lined checks\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmorTek coating technology\u003c\/strong\u003e resists corrosion of internals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial-strength sensing hose\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField reversible relief valve\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir-in\/water-out relief valve design\u003c\/strong\u003e provides maximum capacity during emergency conditions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796775772437,"sku":"88009322","price":28530.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/182338.jpg?v=1772729429"},{"product_id":"6-957n-nrs-fs","title":"6 957N-NRS-FS","description":"\u003cp\u003eThis 6 inch Reduced Pressure Zone Assembly Backflow Preventer is designed to prevent the reverse flow of liquids into potable water systems due to backpressure or backsiphonage, mitigating potential health hazards.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFeatures a \u003cstrong\u003eflood sensor with SentryPlus Alert® technology\u003c\/strong\u003e to detect continuous discharge from the relief valve.\u003c\/li\u003e\n\u003cli\u003eAn add-on connection kit (sold separately) is required to activate the flood sensor for external communication to a Building Automation System (BAS) or the Nexa® platform via Wi-Fi. Without the kit, the sensor remains a passive component.\u003c\/li\u003e\n\u003cli\u003eConstructed with a durable \u003cstrong\u003e304 (Schedule 40) stainless steel housing and sleeve\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eEquipped with \u003cstrong\u003eUL Classified and FM Approved outside stem and yoke (OS\u0026amp;Y) resilient seated gate valves\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003ehorizontal N-pattern installation\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eUtilizes a compact design, making it lighter and allowing for installation in smaller enclosures compared to traditional assemblies.\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003ereplaceable check disc rubber\u003c\/strong\u003e and a bottom-mounted cast stainless steel relief valve.\u003c\/li\u003e\n\u003cli\u003eFeatures \u003cstrong\u003egroove couplings\u003c\/strong\u003e for ease of installation and proper pipe alignment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796776132885,"sku":"F111611","price":16182.21,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/182355.jpg?v=1772729445"},{"product_id":"6-957z-osy-fs","title":"6 957Z-OSY-FS","description":"\u003cp\u003eThis \u003cstrong\u003e6 inch\u003c\/strong\u003e Watts Series 957 \u003cstrong\u003eReduced Pressure Zone (RPZ) assembly backflow preventer\u003c\/strong\u003e provides essential protection for potable water systems, preventing contamination from backsiphonage or backpressure in health hazard applications. Its extremely compact and lightweight design is approved for horizontal \u003cstrong\u003eZ-pattern installation\u003c\/strong\u003e, ensuring proper flow direction.\u003c\/p\u003e\u003cp\u003eThe assembly features a durable \u003cstrong\u003e304 (Schedule 40) stainless steel housing and sleeve\u003c\/strong\u003e, torsion spring check valves, and resilient seated gate valves with outside stem and yoke.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFlood Detection System\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIncludes a \u003cstrong\u003eflood sensor with SentryPlus Alert® technology\u003c\/strong\u003e to detect excessive water discharges from the relief valve.\u003c\/li\u003e\n\u003cli\u003eAn \u003cstrong\u003eadd-on sensor connection kit\u003c\/strong\u003e is required to activate the flood sensor and enable communication.\u003c\/li\u003e\n\u003cli\u003eIntegrates with the \u003cstrong\u003eSensor Control Monitor\u003c\/strong\u003e to deliver maintenance alerts to BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi connectivity.\u003c\/li\u003e\n\u003cli\u003eCompatible with \u003cstrong\u003eBMS\u003c\/strong\u003e and \u003cstrong\u003ecellular network communication\u003c\/strong\u003e when paired with the connection kit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConstruction \u0026amp; Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL and FM approved outside stem and yoke (OSY) resilient seated gate valves\u003c\/strong\u003e for reliable shutoff.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaceable check disc rubber\u003c\/strong\u003e for easy maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBottom mounted cast stainless steel relief valve\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroove couplings\u003c\/strong\u003e allow for integral pipeline adjustment and ease of installation.\u003c\/li\u003e\n\u003cli\u003ePatented torsion spring checks provide the \u003cstrong\u003elowest pressure loss\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003eunmatched ease of serviceability\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eCompact design is \u003cstrong\u003e70% lighter than traditional designs\u003c\/strong\u003e, allowing for smaller enclosures.\u003c\/li\u003e\n\u003cli\u003eThe wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight, meeting \u003cstrong\u003e\"Lead Free\"\u003c\/strong\u003e requirements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796776591637,"sku":"F111599","price":21518.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/182377.jpg?v=1772729464"},{"product_id":"6-957z-nrs-fs","title":"6 957Z-NRS-FS","description":"\u003cp\u003eThis 6 inch Watts Series 957 Reduced Pressure Zone (RPZ) backflow preventer is designed to protect potable water systems from contamination caused by backpressure or backsiphonage, especially in health hazard applications.\u003c\/p\u003e\u003cp\u003eThe extremely compact assembly features an integrated flood sensor with SentryPlus Alert® technology to detect continuous discharge from the relief valve, providing an advanced layer of protection against potential flooding. It is approved for Z-pattern horizontal installation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e6 inch\u003c\/strong\u003e nominal size with a \u003cstrong\u003eZ-pattern\u003c\/strong\u003e orientation for specific installation needs.\u003c\/li\u003e\n\u003cli\u003eIntegrated \u003cstrong\u003eflood sensor\u003c\/strong\u003e with SentryPlus Alert® technology detects excessive water discharges from the relief valve. \u003cem\u003eNOTICE: An add-on sensor connection kit is required to activate the flood sensor. Without the connection kit, the sensor is a passive component that has no communication with any other device.\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eConstructed with a durable \u003cstrong\u003e304 (Schedule 40) stainless steel\u003c\/strong\u003e housing and sleeve.\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003eUL Classified and FM Approved non-rising stem (NRS) resilient seated gate valves\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eFeatures \u003cstrong\u003ereplaceable check disc rubber\u003c\/strong\u003e for easy maintenance.\u003c\/li\u003e\n\u003cli\u003eEquipped with a bottom mounted \u003cstrong\u003eLead Free* cast stainless steel relief valve\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eDesigned with \u003cstrong\u003egroove fittings\u003c\/strong\u003e for straightforward installation and pipeline alignment.\u003c\/li\u003e\n\u003cli\u003eExtremely compact design is \u003cstrong\u003e70% lighter than traditional designs\u003c\/strong\u003e, allowing for smaller enclosures.\u003c\/li\u003e\n\u003cli\u003ePatented torsion spring checks provide the \u003cstrong\u003elowest pressure loss\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796776821013,"sku":"F111617","price":16181.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/182389.jpg?v=1772729476"},{"product_id":"6-957-osy-fs","title":"6 957-OSY-FS","description":"\u003cp\u003eThe WATTS 6 inch Series 957 Reduced Pressure Zone (RPZ) backflow preventer with OSY shutoff valves provides robust protection for potable water systems against contamination from backpressure or backsiphonage, commonly found in health hazard applications. This assembly features an extremely compact, lightweight design, approved for horizontal installation.\u003c\/p\u003e\u003cp\u003eThe unit includes a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. When paired with an optional add-on connection kit, this sensor actively relays alerts for potential flooding events, helping prevent costly damage. Connection kit options enable integration with Building Management Systems (BMS), cellular communication, or the Nexa® platform via Wi-Fi.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFlood sensor with \u003cstrong\u003eSentryPlus Alert® technology\u003c\/strong\u003e detects continuous discharge from the relief valve.\u003c\/li\u003e\n\u003cli\u003eAdd-on sensor connection kit extends flood monitoring on compatible assemblies (sold separately).\u003c\/li\u003e\n\u003cli\u003eIntegrates with Sensor Control Monitor for maintenance alerts to BAS via \u003cstrong\u003eRS-485 Modbus\u003c\/strong\u003e or Nexa® platform by Wi-Fi connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e304 (Schedule 40) stainless steel\u003c\/strong\u003e housing and sleeve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Classified\u003c\/strong\u003e and \u003cstrong\u003eFM Approved\u003c\/strong\u003e outside stem and yoke (OSY) resilient seated gate valves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaceable check disc rubber\u003c\/strong\u003e for easy maintenance.\u003c\/li\u003e\n\u003cli\u003eBottom mounted cast stainless steel relief valve.\u003c\/li\u003e\n\u003cli\u003eExtremely \u003cstrong\u003ecompact design\u003c\/strong\u003e allows for smaller enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroove couplings\u003c\/strong\u003e for ease of installation and pipe alignment.\u003c\/li\u003e\n\u003cli\u003ePatented torsion spring checks provide \u003cstrong\u003elowest pressure loss\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eUnmatched ease of serviceability.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eNOTICE: The flood sensor does not replace the need to comply with all required installation instructions, codes, and regulations related to proper drainage in the event of a discharge. Watts is not responsible for alert failures due to connectivity issues, power outages, or improper installation. Always consult a trained product installer and local authorities for specific installation requirements.\u003c\/em\u003e\u003c\/p\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796776853781,"sku":"F111587","price":14720.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/182388.jpg?v=1772729477"},{"product_id":"6-957-dosy-fs","title":"6 957-DOSY-FS","description":"\u003cp\u003eThis 6 inch Reduced Pressure Zone (RPZ) assembly backflow preventer helps stop the reverse flow of liquids due to backpressure or backsiphonage, particularly where potential health hazards exist in the potable water system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProvides protection against contamination from backpressure and backsiphonage in health hazard applications.\u003c\/li\u003e\n\u003cli\u003eExtremely \u003cstrong\u003ecompact design\u003c\/strong\u003e is 70% lighter than traditional models, allowing for use in smaller enclosures.\u003c\/li\u003e\n\u003cli\u003eIncludes a \u003cstrong\u003eflood sensor with SentryPlus Alert® technology\u003c\/strong\u003e to detect continuous discharge from the relief valve.\u003c\/li\u003e\n\u003cli\u003eFlood alerts are activated with an add-on sensor connection kit, compatible with BMS and cellular network communication.\u003c\/li\u003e\n\u003cli\u003eIntegrates with the Sensor Control Monitor to deliver maintenance alerts to BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi connectivity (with add-on kit).\u003c\/li\u003e\n\u003cli\u003eFeatures \u003cstrong\u003edomestic outside stem and yoke (OSY) resilient seated gate valves\u003c\/strong\u003e for dependable shutoff.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePatented torsion spring check modules\u003c\/strong\u003e provide lowest pressure loss and unmatched ease of serviceability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroove couplings\u003c\/strong\u003e facilitate ease of installation and pipe alignment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eHousing and sleeve are constructed from \u003cstrong\u003e304 (Schedule 40) stainless steel pipe\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eFeatures \u003cstrong\u003ecorrosion-resistant stainless steel bottom mounted pressure relief valve\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eEquipped with \u003cstrong\u003edrip tight shutoff valves\u003c\/strong\u003e and torsion spring check modules with replaceable elastomer discs.\u003c\/li\u003e\n\u003cli\u003eApproved for \u003cstrong\u003ehorizontal installation\u003c\/strong\u003e in accordance with the direction of the flow arrow.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eNOTICE: An add-on connection kit is required to activate the flood sensor. Without the connection kit, the sensor is a passive component that has no communication with any other device.\u003c\/em\u003e\u003c\/p\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796776984853,"sku":"F113043","price":16603.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/182399.jpg?v=1772729484"},{"product_id":"6-994-osy-fs","title":"6 994-OSY-FS","description":"\u003cp\u003eThis \u003cstrong\u003eWatts Series 994 6 inch Reduced Pressure Zone Assembly Backflow Preventer\u003c\/strong\u003e is designed to protect potable water supplies from backsiphonage and backpressure of hazardous materials at cross-connections. It features a compact modular design for easy maintenance and a \u003cstrong\u003eSentryPlus Alert® flood sensor\u003c\/strong\u003e to detect excessive relief valve discharge.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEquipped with a \u003cstrong\u003eflood sensor with SentryPlus Alert® technology\u003c\/strong\u003e to detect continuous discharge from the relief valve.\u003c\/li\u003e\n\u003cli\u003eSupports integration with a \u003cstrong\u003eSensor Control Monitor\u003c\/strong\u003e for maintenance alerts via \u003cstrong\u003eBAS (RS-485 Modbus)\u003c\/strong\u003e or the \u003cstrong\u003eNexa® platform (Wi-Fi connectivity)\u003c\/strong\u003e using an add-on connection kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Classified and FM Approved outside stem and yoke (OSY) resilient seated gate valves\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBottom mounted relief valve\u003c\/strong\u003e reduces clearance requirements for installations against outside walls.\u003c\/li\u003e\n\u003cli\u003eNo special tools are required for servicing, simplifying maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConstruction \u0026amp; Design\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eConstructed with a \u003cstrong\u003estainless steel body\u003c\/strong\u003e for long-term \u003cstrong\u003ecorrosion resistance\u003c\/strong\u003e and maximum strength.\u003c\/li\u003e\n\u003cli\u003eFeatures a short lay length and a lightweight body, reducing installation and shipping costs.\u003c\/li\u003e\n\u003cli\u003eIncorporates \u003cstrong\u003epatented torsion spring check valves\u003c\/strong\u003e for maximum flow at low pressure drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermoplastic and stainless steel check valves\u003c\/strong\u003e ensure trouble-free operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel relief valve\u003c\/strong\u003e with a balanced rolling diaphragm eliminates sliding seals and lowers maintenance costs.\u003c\/li\u003e\n\u003cli\u003eCompact design allows for installation in smaller enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eAn add-on connection kit is required to activate the flood sensor's communication features; without it, the sensor is passive. Watts is not responsible for alert failures due to connectivity issues, power outages, or improper installation. The flood sensor does not replace the need to comply with all required installation, operation, and maintenance regulations, including providing proper drainage for discharge.\u003c\/em\u003e\u003c\/p\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796778688789,"sku":"F438057","price":17702.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/182464.jpg?v=1772729544"},{"product_id":"6-994-osy-gxg-fs","title":"6 994-OSY-GxG-FS","description":"\u003cp\u003eThe Watts 6 inch Series 994 Reduced Pressure Zone Assembly is designed to prevent the reverse flow of liquids into the potable water supply, protecting against health hazards caused by backpressure or backsiphonage. This lead-free backflow preventer features a compact, short lay length design with a lightweight stainless steel body, making installation and maintenance easier.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Free\u003c\/strong\u003e construction ensures the wetted surface contains less than 0.25% lead by weight.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel body\u003c\/strong\u003e provides long term corrosion resistance and maximum strength, and is half the weight of competitive designs for reduced installation and shipping costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutside Stem and Yoke (OSY) grooved gate valves\u003c\/strong\u003e on both inlet and outlet.\u003c\/li\u003e\n\u003cli\u003ePatented \u003cstrong\u003etorsion spring check valves\u003c\/strong\u003e provide maximum flow at low pressure drop and offer trouble-free operation.\u003c\/li\u003e\n\u003cli\u003eBottom mounted relief valve reduces clearance requirements when installed against an outside wall.\u003c\/li\u003e\n\u003cli\u003eNo special tools required for servicing.\u003c\/li\u003e\n\u003cli\u003eCompact construction allows for smaller enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel relief valve\u003c\/strong\u003e features a balanced rolling diaphragm to eliminate sliding seals and lower maintenance costs.\u003c\/li\u003e\n\u003cli\u003eIntegrated \u003cstrong\u003eflood sensor with SentryPlus Alert® technology\u003c\/strong\u003e detects excessive water discharges from the relief valve.\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003eAn add-on sensor connection kit is required to activate the flood sensor's alert feature. Without the connection kit, the flood sensor is a passive component and will not communicate with other devices.\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003eFlood alerts can be activated via BMS, cellular communication, or the Sensor Control Monitor for integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796779409685,"sku":"F438609","price":18940.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/182491.jpg?v=1772729565"},{"product_id":"6-957-osy-gxg-fs","title":"6 957-OSY-GxG-FS","description":"\u003cp\u003eThis Watts 6 inch Reduced Pressure Zone (RPZ) assembly backflow preventer offers robust protection for potable water systems against contamination from backsiphonage or backpressure, particularly in health hazard applications.\u003c\/p\u003e\u003cp\u003eIt features a \u003cstrong\u003elead-free 304 (Schedule 40) stainless steel\u003c\/strong\u003e housing and sleeve, equipped with \u003cstrong\u003eOSY (Outside Stem and Yoke) grooved inlet by grooved outlet gate valves\u003c\/strong\u003e that clearly indicate valve position and prevent stem corrosion. The assembly includes a \u003cstrong\u003eSentryPlus Alert flood sensor\u003c\/strong\u003e designed to detect continuous discharges from the relief valve.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFlood Sensor Technology\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThe integrated flood sensor with \u003cstrong\u003eSentryPlus Alert technology\u003c\/strong\u003e detects excessive water discharges from the relief valve.\u003c\/li\u003e\n\u003cli\u003eTo activate flood monitoring and receive alerts, an \u003cstrong\u003eadd-on sensor connection kit is required\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConnection kit options include BMS, cellular communication, and the Sensor Control Monitor, allowing integration with Building Automation Systems (BAS) via RS-485 Modbus or the Nexa platform through Wi-Fi connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConstruction \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThe assembly incorporates \u003cstrong\u003epositive seated torsion spring check modules\u003c\/strong\u003e, a bottom mounted differential pressure relief valve, and top mounted test cocks for simplified servicing.\u003c\/li\u003e\n\u003cli\u003eFeatures an extremely compact design, approximately \u003cstrong\u003e70% lighter than traditional assemblies\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroove fittings\u003c\/strong\u003e enable integral pipeline adjustment during installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePatented torsion spring checks\u003c\/strong\u003e provide the lowest pressure loss for efficient operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796779868437,"sku":"F112065","price":14694.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/182514.jpg?v=1772729574"},{"product_id":"6-994-nrs-fs","title":"6 994-NRS-FS","description":"\u003cp\u003eThe 6 inch Lead Free Watts Series 994 Reduced Pressure Zone Assembly Backflow Preventer is designed to protect potable water supplies from health hazard cross-connections where reverse flow due to backpressure or backsiphonage may occur.\u003c\/p\u003e\u003cp\u003eThis assembly features a compact, modular design for easy in-line maintenance and includes an integrated flood sensor with SentryPlus Alert® technology for detecting excessive water discharges from the relief valve.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConstruction \u0026amp; Design\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFeatures a \u003cstrong\u003eshort lay length\u003c\/strong\u003e, \u003cstrong\u003elightweight stainless steel body\u003c\/strong\u003e that is half the weight of competitive designs, reducing installation and shipping costs.\u003c\/li\u003e\n\u003cli\u003eEquipped with \u003cstrong\u003ecorrosion resistant stainless steel relief valve\u003c\/strong\u003e and \u003cstrong\u003epatented torsion spring check valves\u003c\/strong\u003e for maximum flow at low pressure drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermoplastic and stainless steel check valves\u003c\/strong\u003e ensure trouble-free operation.\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003enon-rising stem resilient seated gate valves\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eA \u003cstrong\u003ebottom mounted relief valve\u003c\/strong\u003e reduces clearance requirements, ideal for installations against an outside wall.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact construction\u003c\/strong\u003e allows for smaller enclosures and requires \u003cstrong\u003eno special tools for servicing\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFlood Detection \u0026amp; Alerting\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIntegrated \u003cstrong\u003eflood sensor with SentryPlus Alert® technology\u003c\/strong\u003e detects continuous discharge from the relief valve.\u003c\/li\u003e\n\u003cli\u003eTo activate flood alerts, an \u003cstrong\u003eadd-on sensor connection kit is required\u003c\/strong\u003e, compatible with BMS, cellular communication, and the Sensor Control Monitor for integration with BAS via RS-485 Modbus or Nexa® platform through Wi-Fi.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796780228885,"sku":"F438056","price":16663.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/182507.jpg?v=1772729586"},{"product_id":"6-957-nrs-gxg-fs","title":"6 957-NRS-GxG-FS","description":"\u003cp\u003eThis \u003cstrong\u003e6 inch lead free stainless steel reduced pressure zone (RPZ) backflow preventer\u003c\/strong\u003e provides superior protection for potable water systems from contamination due to backsiphonage or backpressure. It is primarily used in health hazard applications to prevent the reverse flow of liquids.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFeatures \u003cstrong\u003enon-rising stem (NRS) gate valves\u003c\/strong\u003e with \u003cstrong\u003egrooved inlet and outlet connections\u003c\/strong\u003e, ideal for installations with limited headroom.\u003c\/li\u003e\n\u003cli\u003eEquipped with a \u003cstrong\u003eflood sensor featuring SentryPlus Alert® technology\u003c\/strong\u003e to detect continuous discharge from the relief valve.\u003c\/li\u003e\n\u003cli\u003eWhen paired with an add-on connection kit (required for activation), the sensor relays alerts for potential flooding events. Connection kit options include \u003cstrong\u003eBMS\u003c\/strong\u003e, \u003cstrong\u003ecellular communication\u003c\/strong\u003e, or the \u003cstrong\u003eSensor Control Monitor\u003c\/strong\u003e for integration with \u003cstrong\u003eBAS via RS-485 Modbus\u003c\/strong\u003e or the \u003cstrong\u003eNexa® platform through Wi-Fi\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eThe assembly boasts an \u003cstrong\u003eextremely compact design\u003c\/strong\u003e with \u003cstrong\u003e304 (Schedule 40) stainless steel housing and sleeve\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003ereplaceable elastomer check discs\u003c\/strong\u003e and \u003cstrong\u003epatented torsion spring checks\u003c\/strong\u003e for lowest pressure loss and unmatched ease of serviceability.\u003c\/li\u003e\n\u003cli\u003eConsists of two independent torsion spring check modules, a bottom mounted differential pressure relief valve, non-rising stem resilient seated shutoff valves, and top mounted test cocks.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796780458261,"sku":"F112071","price":13826.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/182489.jpg?v=1772729597"},{"product_id":"6-994-lf-fs","title":"6 994-LF-FS","description":"\u003cp\u003eThis 6 inch \u003cstrong\u003eWatts Series 994 Lead Free Reduced Pressure Zone (RPZ) Assembly\u003c\/strong\u003e backflow preventer is designed to protect potable water supplies from health hazard cross-connections caused by backsiphonage and backpressure.\u003c\/p\u003e\u003cp\u003eThis model is assembled \u003cstrong\u003ewithout shutoff valves\u003c\/strong\u003e and features a \u003cstrong\u003eshort lay length\u003c\/strong\u003e, a durable \u003cstrong\u003estainless steel body\u003c\/strong\u003e, and includes an integrated \u003cstrong\u003eflood sensor with SentryPlus Alert® technology\u003c\/strong\u003e to detect excessive water discharges from the relief valve, signaling potential flooding.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Free\u003c\/strong\u003e construction, ensuring the wetted surfaces contain less than 0.25% lead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel body\u003c\/strong\u003e provides long-term corrosion resistance and maximum strength, weighing half that of competitive designs to reduce installation costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort end-to-end dimensions\u003c\/strong\u003e make retrofit easy and compact construction allows for smaller enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePatented torsion spring check valves\u003c\/strong\u003e (thermoplastic and stainless steel) provide maximum flow at low pressure drop and trouble-free operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBottom mounted stainless steel relief valve\u003c\/strong\u003e features a balanced rolling diaphragm to eliminate sliding seals and lower maintenance costs, reducing clearance requirements when installed against an outside wall.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlood sensor with SentryPlus Alert® technology\u003c\/strong\u003e detects excessive water discharges from the relief valve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlood alert feature\u003c\/strong\u003e is activated with an add-on sensor connection kit, compatible with BMS and cellular network communication.\u003c\/li\u003e\n\u003cli\u003eMaintenance is simplified with \u003cstrong\u003eno special tools required\u003c\/strong\u003e for servicing and a single access cover for in-line repairs.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796781277461,"sku":"F438058","price":13796.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/182560.jpg?v=1772729632"},{"product_id":"6-lf909-nrs-fs","title":"6 LF909-NRS-FS","description":"\u003cp\u003eThis 6 inch \u003cstrong\u003eLead Free Reduced Pressure Zone Backflow Preventer Assembly\u003c\/strong\u003e prevents the reverse flow of polluted water into the potable water supply due to backsiphonage or backpressure. It is ideal for use in \u003cstrong\u003econtinuous pressure piping applications\u003c\/strong\u003e and at cross-connections with health hazards and other contaminants at the service line entrance.\u003c\/p\u003e\u003cp\u003eThis assembly consists of an \u003cstrong\u003eepoxy coated cast iron body\u003c\/strong\u003e, \u003cstrong\u003enon-rising stem resilient seated gate valves\u003c\/strong\u003e, \u003cstrong\u003ecaptured spring check valves\u003c\/strong\u003e, \u003cstrong\u003ereplaceable seats\u003c\/strong\u003e, \u003cstrong\u003etop mounted test cocks\u003c\/strong\u003e, and a \u003cstrong\u003efield reversible pressure differential relief valve\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIncludes a \u003cstrong\u003eflood sensor with SentryPlus Alert® technology\u003c\/strong\u003e to detect continuous discharge from the relief valve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmorTek® coating technology\u003c\/strong\u003e resists corrosion of internal and external surfaces, limiting microbial induced (MIC) and exposed metal substrate corrosion.\u003c\/li\u003e\n\u003cli\u003ePatented \u003cstrong\u003e3-part advanced epoxy coating system\u003c\/strong\u003e for robust protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnique air-in and water-out design\u003c\/strong\u003e for high capacity relief valve discharge during emergency conditions.\u003c\/li\u003e\n\u003cli\u003eEquipped with \u003cstrong\u003eNon-Rising Stem (NRS) resilient seated gate valves\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eAdd-on \u003cstrong\u003esensor connection kit\u003c\/strong\u003e capability extends flood monitoring.\u003c\/li\u003e\n\u003cli\u003eIntegration with \u003cstrong\u003eSensor Control Monitor\u003c\/strong\u003e for maintenance alerts to BAS via RS-485 Modbus or Nexa® platform by Wi-Fi.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eThe installation of a drain line is recommended, and an air gap is necessary when installing a drain line.\u003c\/em\u003e\u003c\/p\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796814405909,"sku":"88009306","price":28526.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/185106.jpg?v=1772822017"},{"product_id":"6-lf909lf-fs","title":"6 LF909LF-FS","description":"\u003cp\u003eThis 6 inch lead-free reduced pressure zone backflow preventer assembly (Series LF909) is designed to protect potable water supplies from cross-connection contamination due to backsiphonage and backpressure. It is ideal for use in continuous pressure piping applications and at cross-connections identified as health hazards.\u003c\/p\u003e\u003cp\u003eThis assembly consists of an epoxy coated cast iron body, captured spring check valves, replaceable seats, top mounted test cocks, and a field reversible pressure differential relief valve. Note that this model is supplied \u003cstrong\u003ewithout shutoff valves\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAdvanced Protection \u0026amp; Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThe backflow preventer's iron components are coated with \u003cstrong\u003eArmorTek®\u003c\/strong\u003e, a patented three-part advanced epoxy system engineered to reduce microbial-induced corrosion (MIC) and protect exposed metal substrate.\u003c\/li\u003e\n\u003cli\u003eIncludes a \u003cstrong\u003eflood sensor with SentryPlus Alert® technology\u003c\/strong\u003e to detect excessive water discharges from the relief valve, providing notification to facility personnel for corrective action when activated with an add-on sensor connection kit.\u003c\/li\u003e\n\u003cli\u003eIts exclusive \u003cstrong\u003eair-in\/water-out relief valve design\u003c\/strong\u003e provides maximum capacity during emergency conditions of combined backsiphonage and backpressure with both checks fouled.\u003c\/li\u003e\n\u003cli\u003eFeatures \u003cstrong\u003eLead Free* construction\u003c\/strong\u003e to comply with lead-free installation requirements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796829053205,"sku":"88009330","price":18465.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/185118.jpg?v=1772823761"},{"product_id":"6-994-dosy","title":"6 994-DOSY","description":"\u003cp\u003eThe Watts Series 994 Reduced Pressure Zone Assembly is a 6 inch backflow preventer designed to protect potable water supplies from backsiphonage and backpressure of hazardous materials. It is suitable for health hazard cross-connections and continuous pressure piping applications, preventing the reverse flow of fire protection substances and water of non-potable quality into the potable water supply.\u003c\/p\u003e\u003cp\u003eIts compact modular design facilitates easy maintenance with a single access cover for in-line repairs.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel body\u003c\/strong\u003e provides long term \u003cstrong\u003ecorrosion resistance\u003c\/strong\u003e and maximum strength.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDomestic outside stem and yoke (OSY) resilient seated gate valves\u003c\/strong\u003e for reliable shutoff control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort lay length\u003c\/strong\u003e and \u003cstrong\u003ecompact construction\u003c\/strong\u003e allow for smaller enclosures and easy retrofit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBottom mounted relief valve\u003c\/strong\u003e reduces clearance requirements when installed against an outside wall.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorsion spring check valves\u003c\/strong\u003e provide maximum flow at low pressure drop and ensure trouble-free operation with thermoplastic and stainless steel hinge pins.\u003c\/li\u003e\n\u003cli\u003eEquipped with a \u003cstrong\u003eflood sensor\u003c\/strong\u003e on the relief valve to detect excessive water discharges.\u003c\/li\u003e\n\u003cli\u003eNo special tools are required for servicing.\u003c\/li\u003e\n\u003cli\u003eThe wetted surface of this product contains less than \u003cstrong\u003e0.25% lead by weight\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cem\u003e\u003cp\u003eAn add-on connection kit is required to activate the flood sensor's alert feature. Without this kit, the flood sensor acts as a passive component and does not communicate with any other device.\u003c\/p\u003e\u003c\/em\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796830757141,"sku":"0439415","price":18939.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/184108.jpg?v=1772731164"},{"product_id":"6-994-dnrs","title":"6 994-DNRS","description":"\u003cp\u003eThe Watts 6 inch reduced pressure zone assembly backflow preventer is designed to prevent the reverse flow of fire protection substances and non-potable water into the potable water supply. It protects against backsiphonage and backpressure in continuous pressure piping applications and at cross-connections identified as health hazards.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCompact modular design with \u003cstrong\u003eshort lay length\u003c\/strong\u003e for easy maintenance and retrofit.\u003c\/li\u003e\n\u003cli\u003eSingle access cover for in-line repairs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e300 Series Stainless steel body\u003c\/strong\u003e for corrosion resistance.\u003c\/li\u003e\n\u003cli\u003eBottom mounted relief valve reduces clearance requirements.\u003c\/li\u003e\n\u003cli\u003ePatented \u003cstrong\u003etorsion spring check valves\u003c\/strong\u003e provide maximum flow at low pressure drop.\u003c\/li\u003e\n\u003cli\u003eThermoplastic check valves with stainless steel hinge pins for trouble-free operation.\u003c\/li\u003e\n\u003cli\u003eNo special tools required for servicing.\u003c\/li\u003e\n\u003cli\u003eIncludes a \u003cstrong\u003esensor on the relief valve for flood detection\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eDomestic \u003cstrong\u003enon-rising stem resilient seated gate valves\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIncludes four ball-type test cocks.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eWatts recommends installing a drain line and the required 994AGK-P air gap for the drain line installation. When installing an air gap, attach the air gap brackets directly onto the flood sensor. Refer to product installation instructions and safety information before beginning installation.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThe information provided is not intended to replace full product installation and safety information or the experience of a trained product installer. Always refer to product installation instructions and safety information before beginning the installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796832002325,"sku":"0439403","price":17825.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/184144.jpg?v=1772731214"},{"product_id":"6-lf909-osy-fs","title":"6 LF909-OSY-FS","description":"\u003cp\u003eThis 6 inch \u003cstrong\u003eLead Free\u003c\/strong\u003e Reduced Pressure Zone (RPZ) Backflow Preventer Assembly, Series LF909, is designed to protect potable water supplies from pollution due to backsiphonage and\/or backpressure. It is ideal for continuous pressure piping applications and safeguarding against health hazard cross-connections and other contaminants.\u003c\/p\u003e\u003cp\u003eThis assembly incorporates advanced features to ensure reliability and longevity, including an integrated flood sensor with \u003cstrong\u003eSentryPlus Alert® technology\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConstruction \u0026amp; Design\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEpoxy coated cast iron body\u003c\/strong\u003e with \u003cstrong\u003eArmorTek®\u003c\/strong\u003e, a patented three-part advanced epoxy coating system, engineered to reduce \u003cstrong\u003emicrobial-induced corrosion (MIC)\u003c\/strong\u003e and protect exposed metal substrate.\u003c\/li\u003e\n\u003cli\u003eFeatures \u003cstrong\u003eoutside stem and yoke (OSY) resilient seated gate valves\u003c\/strong\u003e for reliable shutoff.\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003ecaptured spring check valves\u003c\/strong\u003e, \u003cstrong\u003ereplaceable seats\u003c\/strong\u003e, and top-mounted test cocks.\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003epressure differential relief valve\u003c\/strong\u003e is field reversible and utilizes a unique patented \u003cstrong\u003eair-in\/water-out design\u003c\/strong\u003e for maximum capacity discharge during emergency conditions.\u003c\/li\u003e\n\u003cli\u003eConstructed to comply with \u003cstrong\u003eLead Free*\u003c\/strong\u003e installation requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFlood Sensor Technology\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEquipped with a \u003cstrong\u003eflood sensor\u003c\/strong\u003e on the relief valve to detect excessive water discharges.\u003c\/li\u003e\n\u003cli\u003eWhen paired with an add-on connection kit, the sensor is activated to relay alerts for potential flooding events to facility personnel.\u003c\/li\u003e\n\u003cli\u003eConnection kit options include \u003cstrong\u003eBMS\u003c\/strong\u003e, \u003cstrong\u003ecellular communication\u003c\/strong\u003e, and the \u003cstrong\u003eSensor Control Monitor\u003c\/strong\u003e, enabling integration with \u003cstrong\u003eBAS via RS-485 Modbus\u003c\/strong\u003e or the \u003cstrong\u003eNexa® platform\u003c\/strong\u003e through Wi-Fi.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eAn add-on connection kit is required to activate the flood sensor. Without the connection kit, the sensor is a passive component with no communication. Watts is not responsible for the failure of alerts due to connectivity issues, power outages, or improper installation.\u003c\/em\u003e\u003c\/p\u003e","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":49796832624917,"sku":"88009305","price":30434.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/185104.jpg?v=1772821945"},{"product_id":"watts-6-lf909-osy-s-fda-fs-reduced-pressure-zone-assembly-lead-free-armortek-coating-osy-shutoff-valves-fda-epoxy-coated-strainer-flood-sensor-35682","title":"Watts® 6\" LF909-OSY-S-FDA-FS Reduced Pressure Zone Assembly, Lead-Free, ArmorTek Coating, OSY Shutoff Valves, FDA Epoxy Coated Strainer, Flood Sensor","description":"","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":50124140675349,"sku":"88009359","price":33809.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/192738.jpg?v=1789044642"},{"product_id":"watts-6-lf909-qt-s-fda-fs-reduced-pressure-zone-assembly-lead-free-armortek-coating-quarter-turn-shutoff-valves-fda-epoxy-coated-strainer-flood-sensor-35516","title":"Watts® 6\" LF909-QT-S-FDA-FS Reduced Pressure Zone Assembly, Lead-Free, ArmorTek Coating, Quarter Turn Shutoff Valves, FDA Epoxy Coated Strainer, Flood Sensor","description":"","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":50124167905557,"sku":"88009335","price":39892.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/192726.jpg?v=1789043693"},{"product_id":"watts-6-lf909-nrs-s-fda-fs-reduced-pressure-zone-assembly-lead-free-armortek-coating-nrs-shutoff-valves-fda-epoxy-coated-strainer-flood-sensor-35528","title":"Watts® 6\" LF909-NRS-S-FDA-FS Reduced Pressure Zone Assembly, Lead-Free, ArmorTek Coating, NRS Shutoff Valves, FDA Epoxy Coated Strainer, Flood Sensor","description":"","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":50124169707797,"sku":"88009332","price":31910.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/192724.jpg?v=1789043646"},{"product_id":"watts-6-lf909-qt-fda-fs-reduced-pressure-zone-assembly-lead-free-armortek-coating-fda-epoxy-coated-quarter-turn-shutoff-valves-flood-sensor-35577","title":"Watts® 6\" LF909-QT-FDA-FS Reduced Pressure Zone Assembly, Lead-Free, ArmorTek Coating, FDA Epoxy Coated Quarter Turn Shutoff Valves, Flood Sensor","description":"","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":50124178161941,"sku":"88009391","price":39072.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/192750.jpg?v=1789047746"},{"product_id":"watts-6-909-cast-iron-reduced-pressure-zone-backflow-preventer-assy-osy-shutoff-with-sentryplus-alert-flood-detection-technology-armortek-coating-36599","title":"Watts 6\" 909 Cast Iron Reduced Pressure Zone Backflow Preventer Assy, OSY Shutoff, with SentryPlus Alert Flood Detection Technology, ArmorTek Coating","description":"This 6\" lead free reduced pressure zone backflow preventer assembly with SentryPlus Alert technology for flood detection is designed to prevent the reverse flow of contaminated water from being pumped or siphoned into the potable water supply due to backsiphonage and or backpressure in accordance with national plumbing codes and water authority requirements, as well as provide continuous monitoring, multi-channel alerts, and automatic shutoff capability in the event of a possible flood condition. The LF909 Backflow preventer features an exclusive air-in-water-out principle relief valve for increased protection during backflow emergencies. The coating on this backflow assembly uses ArmorTek(R), a patented 3-part advanced epoxy coating system designed to limit both microbial induced (MIC) and exposed metal substrate corrosion. The assembly uses OSY shutoffs. This backflow assembly also includes a backflow flood sensor alert that monitors the condition of your backflow assembly 24\/7 and alerts you in the event of RPZ discharge. Simply connect to the SentryPlus Alert System or to your BMS and activate it.","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":50164298547477,"sku":"DDP0113181","price":34216.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/193526.jpg?v=1789570337"},{"product_id":"watts-6-957-reduced-pressure-zone-assembly-backflow-preventer-nrs-shutoff-valves-with-sentryplus-alert-flood-detection-technology-36638","title":"Watts 6\" 957 Reduced Pressure Zone Assembly Backflow Preventer, NRS Shutoff Valves, with SentryPlus Alert Flood Detection Technology","description":"This 6\" stainless steel reduced pressure zone assembly backflow preventer with SentryPlus Alert technology with automatic shutoff ACV for flood detection and prevention is designed to prevent the reverse flow of contaminated water from being pumped or siphoned into the potable water supply due to backsiphonage and or backpressure in accordance with national plumbing codes and water authority requirements, as well as provide continuous monitoring and multi-channel alerts in the event of a possible flood condition. The backflow preventer is extremely light and compact compared to a traditional backflow assembly, and features a quick access sleeve.","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":50164306444565,"sku":"DDP0113125","price":17481.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/193572.jpg?v=1789574185"},{"product_id":"watts-6-909-cast-iron-reduced-pressure-zone-backflow-preventer-assy-osy-shutoff-with-sentryplus-alert-flood-prevention-system-automatic-shutoff-acv-armortek-coating-36676","title":"Watts 6\" 909 Cast Iron Reduced Pressure Zone Backflow Preventer Assy, OSY Shutoff, with SentryPlus Alert Flood Prevention System, Automatic Shutoff ACV, ArmorTek Coating","description":"This 6\" lead free reduced pressure zone backflow preventer assembly with SentryPlus Alert technology with automatic shutoff ACV for flood detection and prevention is designed to prevent the reverse flow of contaminated water from being pumped or siphoned into the potable water supply due to backsiphonage and or backpressure in accordance with national plumbing codes and water authority requirements, as well as provide continuous monitoring, multi-channel alerts, and automatic shutoff capability in the event of a possible flood condition. This LF909 assembly features an exclusive relief valve design provides maximum capacity during emergency conditions. The coating on this backflow assembly uses ArmorTek(R), a patented 3-part advanced epoxy coating system designed to limit both microbial induced (MIC) and exposed metal substrate corrosion. SentryPlus Alert utilizes the Watts LFF113RFP ACV as an automatic shutoff valve in the event of a potential flood condition. The assembly uses OSY shutoffs. This backflow assembly also includes a backflow flood sensor alert that monitors the condition of your backflow assembly 24\/7 and alerts you in the event of RPZ discharge. Simply connect to the SentryPlus Alert System or to your BMS and activate it.","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":50164312604949,"sku":"DDP0113157","price":55512.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/193790.jpg?v=1789653693"},{"product_id":"watts-6-957-reduced-pressure-zone-assembly-backflow-preventer-nrs-shutoffs-with-sentryplus-alert-flood-prevention-system-and-automatic-shutoff-acv-36681","title":"Watts 6\" 957 Reduced Pressure Zone Assembly Backflow Preventer, NRS Shutoffs, with SentryPlus Alert Flood Prevention System and Automatic Shutoff ACV","description":"This 6\" stainless steel reduced pressure zone assembly backflow preventer with SentryPlus Alert technology with automatic shutoff ACV for flood detection and prevention is designed to prevent the reverse flow of contaminated water from being pumped or siphoned into the potable water supply due to backsiphonage and or backpressure in accordance with national plumbing codes and water authority requirements, as well as provide alerts and automatic shutoff capability in the event of a possible flood condition. The backflow preventer is extremely light and compact compared to a traditional backflow assembly, and features a quick access sleeve. SentryPlus Alert utilizes the Watts LFF113RFP ACV as an automatic shutoff valve in the event of a potential flood condition.","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":50164313358613,"sku":"DDP0113113","price":38779.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/193795.jpg?v=1789653877"},{"product_id":"watts-6-957-reduced-pressure-zone-assembly-backflow-preventer-osy-shutoffs-with-sentryplus-alert-flood-prevention-system-and-automatic-shutoff-acv-36689","title":"Watts 6\" 957 Reduced Pressure Zone Assembly Backflow Preventer, OSY Shutoffs, with SentryPlus Alert Flood Prevention System and Automatic Shutoff ACV","description":"This 6\" reduced pressure zone assembly backflow preventer with SentryPlus Alert technology with automatic shutoff ACV for flood detection and prevention is designed to prevent the reverse flow of contaminated water from being pumped or siphoned into the potable water supply due to backsiphonage and or backpressure in accordance with national plumbing codes and water authority requirements, as well as provide alerts and automatic shutoff capability in the event of a possible flood condition. The backflow preventer is extremely light and compact compared to a traditional backflow assembly, and features a quick access sleeve. SentryPlus Alert utilizes the Watts LFF113RFP ACV as an automatic shutoff valve in the event of a potential flood condition.","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":50164314308885,"sku":"DDP0113119","price":39654.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/193804.jpg?v=1789654647"},{"product_id":"watts-6-909-cast-iron-reduced-pressure-zone-backflow-preventer-assy-nrs-shutoff-with-sentryplus-alert-flood-prevention-system-automatic-shutoff-acv-armortek-coating-36729","title":"Watts 6\" 909 Cast Iron Reduced Pressure Zone Backflow Preventer Assy, NRS Shutoff, with SentryPlus Alert Flood Prevention System, Automatic Shutoff ACV, ArmorTek Coating","description":"This 6\" lead free reduced pressure zone backflow preventer assembly with SentryPlus Alert technology with automatic shutoff ACV for flood detection and prevention is designed to prevent the reverse flow of contaminated water from being pumped or siphoned into the potable water supply due to backsiphonage and or backpressure in accordance with national plumbing codes and water authority requirements, as well as provide continuous monitoring, multi-channel alerts, and automatic shutoff capability in the event of a possible flood condition. This LF909 assembly features an exclusive relief valve design provides maximum capacity during emergency conditions. The coating on this backflow assembly uses ArmorTek(R), a patented 3-part advanced epoxy coating system designed to limit both microbial induced (MIC) and exposed metal substrate corrosion. SentryPlus Alert utilizes the Watts LFF113RFP ACV as an automatic shutoff valve in the event of a potential flood condition. The assembly uses NRS shutoffs. This backflow assembly also includes a backflow flood sensor alert that monitors the condition of your backflow assembly 24\/7 and alerts you in the event of RPZ discharge. Simply connect to the SentryPlus Alert System or to your BMS and activate it.","brand":"Water Specialties Company","offers":[{"title":"Default Title","offer_id":50164317323541,"sku":"DDP0113151","price":53616.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/6506\/6773\/files\/193845.jpg?v=1789658597"}],"url":"https:\/\/www.backflowpreventer.com\/collections\/backflow-devices-watts-rpz-reduced-pressure-zone-assemblies-6.oembed","provider":"Water Specialties Company","version":"1.0","type":"link"}