1 1/4 009M2-QT-FS

Item Number: 88004033
Skip to product information
1 of 1
Regular price $1,608.62
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Watts

  • Bronze body construction for durability
  • Weight: 15.4 lb
  • NPT inlet and outlet connections
  • Quarter turn ball valve shutoffs with tee handles
  • Flood sensor with SentryPlus Alert® technology included
  • Single access cover for easy maintenance
  • Max. Supply Pressure: 175 psi
  • Water Temperature Range: 33°F – 180°F
  • ASSE 1013, AWWA C511-92, CSA B64.4 approved

Description

This Watts Series 009 1 1/4 inch Reduced Pressure Zone (RPZ) Assembly Backflow Preventer is designed to protect potable water supplies from dangerous cross-connections, preventing backflow due to backsiphonage or backpressure. It features durable bronze body construction, NPT connections, and quarter-turn ball valve shutoffs. An integrated flood sensor with SentryPlus Alert® technology detects excessive water discharges, offering enhanced protection against potential flooding when paired with an add-on connection kit. The compact modular design allows for easy maintenance with a single access cover. Approved to ASSE 1013, AWWA C511-92, and CSA B64.4 standards, it operates up to 175 psi.

Help Me Connect

System Connections

This 1 1/4 inch backflow preventer features standard NPT body connections for easy integration into your piping system. It includes quarter turn full port resilient seated ball valve shutoffs with tee handles on both the inlet and outlet.

Flood Sensor Connectivity

The integrated flood sensor with SentryPlus Alert® technology requires an add-on connection kit (sold separately) to become active and relay alerts. Without a connection kit, the sensor is a passive component with no communication. Available connection kit options include BMS, cellular communication, or the Sensor Control Monitor, which allows integration with Building Automation Systems (BAS) via RS-485 Modbus or the Nexa® platform via Wi-Fi.

View full details

Collapsible content

Additional Details

This Watts Series 009 Reduced Pressure Zone Assembly Backflow Preventer helps prevent the flow of polluted water from entering into the potable water supply due to backsiphonage and/or backpressure, in accordance with national plumbing codes and water authority requirements. Its compact modular design facilitates easy maintenance with a single access cover for in-line repairs.

This assembly is ideal for protection in continuous pressure piping applications and at cross-connections identified as health hazards and for contaminants at the service line entrance.

WARNING: It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing, consult your local water authority, building, and plumbing codes.

Key Features

  • Bronze body construction for durability.
  • NPT inlet and outlet connections for straightforward installation.
  • Quarter turn full port resilient seated ball valve shutoffs with tee handles.
  • Includes a flood sensor with SentryPlus Alert® technology to detect continuous discharge from the relief valve.
  • Single access cover and modular check construction for ease of maintenance and in-line repairs.
  • Top entry to all internals for immediate accessibility.
  • Captured springs for safe maintenance.
  • Internal relief valve for reduced installation clearances.
  • Replaceable check seats for economical repair.
  • Large body passages provide low pressure drop.
  • Compact, space-saving design requires no special tools for servicing.

Flood Sensor Details

  • Flood sensor detects excessive water discharges from the relief valve.
  • When paired with an add-on connection kit (sold separately), the sensor is activated to relay alerts for potential flooding events.
  • Connection kit options include BMS, cellular communication, and the Sensor Control Monitor for integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.

Specifications

General

  • Assembly Type: Reduced Pressure Zone (RPZ) Backflow Preventer
  • Product Series: Watts Series 009
  • Nominal Size: 1 1/4 inch
  • Body Material: Bronze
  • Connection Type: NPT
  • Shutoff Valves: Quarter Turn Ball Valves with Tee Handles
  • Test Cocks: Four Resilient Seated
  • Check Valves: Two In-Line Independent
  • Relief Valve: Internal
  • Flood Sensor: Yes, SentryPlus Alert® Technology

Performance

  • Maximum Supply Pressure: 175 psi (12.1 bar)
  • Water Temperature Range: 33°F – 180°F (0.5°C – 75°C)

Certificates & Approvals

  • USC
  • ASSE No. 1013
  • AWWA C511-92
  • CSA B64.4
  • IAPMO File No. 1563
  • Approved by Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California
  • UL Classified: 3/4" - 2"

FAQs

What is the primary function of this backflow preventer?

This backflow preventer is designed to protect potable water supplies from contamination by preventing the flow of polluted water from entering due to backsiphonage or backpressure in non-potable service applications.

What is the purpose of the integrated flood sensor?

The integrated flood sensor with SentryPlus Alert® technology detects excessive water discharges from the relief valve. When paired with an add-on connection kit (sold separately), it can relay alerts for potential flooding events.

What are the connection types for this assembly?

This backflow preventer is furnished with NPT (National Pipe Taper) body connections for both the inlet and outlet, ensuring compatibility with standard threaded piping systems.

What materials are used in its construction?

The assembly features a durable bronze body construction. It uses silicone rubber disc material in the check valves and relief valve, with replaceable polymer check seats.

Are there specific installation requirements or certifications?

Yes, it is illegal to use this product for human consumption systems in the US. It meets requirements from USC, ASSE No. 1013, AWWA C511-92, CSA B64.4, and IAPMO File No. 1563. Always consult local water authority and plumbing codes before installation.