1 1/4 850-QT-FZ DC

Item Number: T1114
Skip to product information
1 of 2
Regular price $884.26
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Febco

  • Nominal Size: 1 1/4 inch
  • Body Material: Bronze
  • Maximum Working Pressure: 175 PSI
  • Temperature Range: 32°F to 140°F
  • Features an integrated freeze sensor
  • End Connections: NPT ANSI/ASME B1.20.1
  • Shutoff Type: Quarter-turn ball valves
  • ASSE 1015 and CSA B64.5 Approved

Description

The FEBCO Series 850 Small Double Check Valve Assembly is a 1 1/4 inch backflow preventer designed for non-health hazard applications. It prevents polluted water from entering potable supplies in continuous pressure piping and non-potable cross-connections. Constructed with a durable bronze body and NPT end connections, it includes quarter-turn ball valve shutoffs. A key feature is the integrated freeze sensor with SentryPlus Alert® technology, which signals facility personnel about low or freezing temperatures to help prevent damage. An add-on connection kit is required to enable the sensor's full monitoring and alert capabilities via Wi-Fi, BMS, or IMS. Item T1114.

Help Me Connect

This 1 1/4 inch double check valve backflow preventer features NPT ANSI/ASME B1.20.1 end connections. Both sides connect to 1 1/4 inch male NPT threads. The integrated freeze sensor requires an add-on connection kit (sold separately) to activate its temperature monitoring system and trigger alerts via Wi-Fi networks, building management systems (BMS), or irrigation management systems (IMS).

View full details

Collapsible content

Additional Details

This 1 1/4 inch small diameter double check valve backflow preventer assembly is designed to prevent the backflow of polluted water from entering into the potable water supply due to backsiphonage and/or backpressure in accordance with national plumbing codes and water authority requirements. It is ideal for protection in continuous pressure piping applications and at cross-connections identified as non-health hazards and for contaminants at the service line entrance.

Features

  • Includes a freeze sensor for use with SentryPlus Alert® technology to monitor temperature and alert facility personnel when freeze conditions can cause damage.
  • Bronze body construction for durability.
  • Modular compact design facilitates easy maintenance with a single access cover for in-line repairs.
  • Consists of two in-line independent positive seating check modules and captured springs.
  • Equipped with NPT end connections and quarter-turn ball valve shutoffs.
  • Features top-mounted test cocks and replaceable check discs and seats.

WARNING: It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes.

WARNING: The freeze sensor solely provides alerts about a possible freeze event and cannot prevent a freeze event from occurring. User action is required to prevent freeze conditions from causing product and/or property damage. Use of the freeze sensor does not replace the need to comply with all required instructions, codes, and regulations related to installation, operation, and maintenance of this product, including the need to provide protection against a freeze event.

Specifications

General

  • Nominal Size: 1 1/4 inch
  • Assembly Type: Double Check Valve Backflow Preventer
  • Operation: Two independently operating, spring-loaded check valves
  • Design: Modular compact design
  • Monitoring: Integrated freeze sensor for SentryPlus Alert® technology

Connections

  • End Connection: NPT ANSI/ASME B1.20.1
  • Shutoff Valves: Quarter-turn ball valves
  • Test Cocks: Top mounted

Materials

  • Valve Body: Bronze
  • Elastomers: Silicone
  • Springs: Stainless steel
  • Seat: Noryl®
  • Poppet: Noryl®
  • Seat Disc: Silicone
  • Disc Retainer: Noryl®

Pressure & Temperature

  • Maximum Working Pressure: 175 psi (12.1 bar)
  • Hydrostatic Test Pressure: 350 psi (24.1 bar)
  • Temperature Range: 32°F to 140°F (0°C to 60°C)

Certificates & Approvals

  • ASSE: 1015
  • CSA: B64.5
  • UPC: Approved
  • USC-FCCCHR: Approved
  • ANSI/AWWA: C510-92 Conformance
  • Foundation for Cross-Connection Control and Hydraulic Research: Approved

FAQs

What is the primary use of this backflow preventer?

This double check valve assembly is designed to prevent the backflow of polluted water into potable water supplies in non-health hazard applications, such as irrigation, fire lines, or industrial processing.

Is this product suitable for drinking water systems?

No, it is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. It is intended for non-potable service applications.

How does the integrated freeze sensor work?

The freeze sensor is designed for use with SentryPlus Alert® technology to monitor temperature and alert facility personnel when conditions approach or reach freezing. An add-on connection kit is required to activate its full monitoring and alert functionality via Wi-Fi, BMS, or IMS.

What are the connection types and sizes for this assembly?

This assembly features 1 1/4 inch NPT ANSI/ASME B1.20.1 end connections, designed to connect to matching male NPT threads.

What materials is this backflow preventer made from?

The valve body is constructed from bronze for durability. Key internal components like elastomers are silicone, while springs are stainless steel, and seats/poppets are Noryl®.