1 1/4 LF919-QT-FS

Item Number: F065374
Skip to product information
1 of 2
Regular price $2,372.18
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Watts

  • Size: 1 1/4 inch
  • Body Material: Lead-free bronze
  • End Connections: NPT
  • Valve Type: Quarter turn ball valves
  • Features SentryPlus Alert flood sensor
  • Detects continuous relief valve discharge
  • Integrates with Sensor Control Monitor for alerts
  • Compact, space-saving design

Description

The Watts 1 1/4 inch Lead Free Reduced Pressure Zone Backflow Preventer Assembly with Quarter Turn Ball Valves is designed to prevent polluted water from entering the potable water supply. This assembly features a SentryPlus Alert flood sensor to detect continuous relief valve discharge, relaying alerts for potential flooding events when paired with an add-on connection kit. Its lead-free bronze body and NPT end connections ensure durable, reliable performance in continuous pressure piping applications. Integration with a Sensor Control Monitor allows for maintenance alerts via BAS (RS-485 Modbus) or Wi-Fi (Nexa platform). This compact unit includes two poppet style check valves and easy-access test cocks.

Help Me Connect

Connecting to Your System

  • This backflow preventer features a built-in flood sensor with SentryPlus Alert technology. To activate and extend flood monitoring capabilities, the sensor must be paired with an add-on connection kit (sold separately).
  • Connection kit options include those for Building Management Systems (BMS), cellular communication, and the Sensor Control Monitor.
  • The Sensor Control Monitor enables seamless integration with a Building Automation System (BAS) via RS-485 Modbus or wirelessly to the Nexa platform through Wi-Fi connectivity.
  • The assembly utilizes standard NPT end connections, designed for direct threaded installation into your piping system.
View full details

Collapsible content

Additional Details

This 1 1/4 inch lead free reduced pressure zone backflow preventer assembly is designed to prevent the flow of polluted water from entering the potable water supply due to backsiphonage and/or backpressure. It includes a flood sensor with SentryPlus Alert technology to detect water discharges from the relief valve, providing crucial safety monitoring for continuous pressure piping applications and health hazard cross-connections.

Flood Sensing & Alerting

  • Features a flood sensor with SentryPlus Alert technology to detect continuous discharge from the relief valve.
  • When paired with an add-on connection kit (sold separately), the sensor activates to relay alerts for potential flooding events.
  • Integrates with the Sensor Control Monitor to deliver maintenance alerts to a Building Automation System (BAS) via RS-485 Modbus or to the Nexa platform by Wi-Fi connectivity.

Construction & Design

  • Lead-free bronze body construction ensures durability and compliance.
  • Includes NPT end connections for easy installation.
  • Features quarter turn ball valve shutoffs with convenient tee handles.
  • Equipped with two poppet style check valves and replaceable check seats for extended service life.
  • Compact, space-saving design with separate access covers for the check valves and relief valve.
  • Top-mounted, screwdriver-slotted test cocks facilitate easy testing, even in reduced clearance installations.
  • EZ twist relief valve cover with a quarter turn locking joint captures the spring load during repair, simplifying disassembly.
  • Bottom-mounted relief valve further contributes to reduced space requirements.

Specifications

  • Assembly Size: 1 1/4 inch
  • Body Material: Lead-free bronze
  • End Connections: NPT
  • Valve Type: Quarter turn ball valves with lever handles
  • Check Valves: Two poppet style
  • Check Seats: Replaceable
  • Relief Valve: Bottom-mounted with EZ twist cover
  • Test Cocks: Top-mounted, screwdriver-slotted
  • Sensor Technology: SentryPlus Alert flood sensor
  • System Integration: RS-485 Modbus, Wi-Fi to Nexa platform (via Sensor Control Monitor)

FAQs

What is the primary purpose of this backflow preventer assembly?

Its primary purpose is to prevent polluted water from flowing back into the potable water supply due to backsiphonage or backpressure, protecting against contamination in continuous pressure piping applications.

What kind of flood detection technology is included?

The assembly includes a flood sensor with SentryPlus Alert technology, designed to detect continuous discharge from the relief valve.

How are alerts communicated from the flood sensor?

When paired with an add-on connection kit, the sensor relays alerts for potential flooding events. It can integrate with a Sensor Control Monitor to send alerts to a Building Automation System (BAS) via RS-485 Modbus or to the Nexa platform via Wi-Fi.

What material is the body of the backflow preventer made from?

The backflow preventer features a lead-free bronze body construction, ensuring durability and compliance with lead-free standards.

What type of end connections does this assembly have?

It is equipped with NPT (National Pipe Taper) end connections, allowing for straightforward threaded installation into your piping system.