10 C500-NRS-G-FS
Item Number: F0191345Brand - Ames
Couldn't load pickup availability
- Size: 10 inch
- Weight: 997.0 lb
- Body Material: 304 Stainless Steel
- Features: SentryPlus Alert® Flood Sensor
- Valve Type: Non-Rising Stem (NRS) Shutoff Valves
- Includes: Gallon Per Minute Meter
- Maximum Working Pressure: 175 psi
- Approvals: UL Classified, FM Approved, CSA B64.4
- Design: Extremely Compact, 70% Lighter
Description
Description
Help Me Connect
Help Me Connect
Flood Sensor Connectivity
- An add-on connection kit is required to activate the flood sensor.
- Without the connection kit, the flood sensor functions as a passive component and will not communicate with other devices.
- Connection kit options include integration with Building Management Systems (BMS), cellular communication, or the Sensor Control Monitor.
- The Sensor Control Monitor enables integration with Building Automation Systems (BAS) via RS-485 Modbus or the Nexa® platform through Wi-Fi connectivity.
Installation
- The assembly utilizes groove fittings for integral pipeline adjustment and easy installation.

Collapsible content
Additional Details
This Colt Series C500 10 inch reduced pressure detector backflow preventer assembly is engineered to prevent the reverse flow of non-potable substances and water into the potable water supply. It provides critical protection at cross-connections identified as health hazards, such as fire sprinkler systems and service line entrances, safeguarding drinking water from backsiphonage and backpressure.
The assembly is also equipped to monitor unauthorized water use from the fire protection system.
Features
- Features a flood sensor with SentryPlus Alert® technology to detect continuous discharge from the relief valve, with an add-on connection kit required for activation and relaying alerts.
- Extremely compact design, approximately 70% lighter than traditional designs.
- Constructed with a 304 (Schedule 40) stainless steel housing and sleeve for durability.
- Includes groove fittings for easy installation and integral pipeline adjustment.
- Patented link check modules for lowest pressure loss and unmatched ease of serviceability.
- Equipped with a gallon per minute meter (metered bypass) to detect underground leaks or unauthorized water usage.
- Features a bottom-mounted cast stainless steel relief valve.
- Non-rising stem (NRS) shutoff valves provide drip-tight closure.
- Replaceable check disc rubber.
It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing, consult your local water authority, building, and plumbing codes.
Specifications
- Product Type: Reduced Pressure Detector Backflow Preventer Assembly
- Model: C500-NRS
- Size: 10 inch
- Body Material: 304 (Schedule 40) Stainless Steel
- Housing & Sleeve Material: 304 (Schedule 40) Stainless Steel
- Elastomer Material: EPDM, Silicone, Buna 'N'
- Link Checks Material: Noryl®, Stainless Steel
- Check Discs Material: Reversible Silicone or EPDM
- Test Cocks Material: Lead-Free Bronze Body, Nickel Plated
- Relief Valve & Fasteners Material: 300 Series Stainless Steel
- Springs Material: Stainless Steel
- Valve Type: Non-Rising Stem (NRS) Shutoff Valves
- Bypass Meter: Gallon Per Minute Meter Included
- Flood Sensor: SentryPlus Alert® Technology Included
- Maximum Working Pressure: 175 psi (12.1 bar)
- Temperature Range: 33°F – 140°F (0.6°C – 60°C)
Certificates & Approvals
- Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR - USC)
- AWWA C511-97
- UL Classified (1047)
- CSA B64.4
- FM Approved