10 C500N-OSY-C-FS
Item Number: F0191323Brand - Ames
Couldn't load pickup availability
- Size: 10 inch
- Weight: 1164.0 lb
- Assembly Type: Reduced Pressure Detector Backflow Preventer
- Shutoff Valves: OSY Resilient Seated Gate Valves
- Body Material: 304 (Schedule 40) Stainless Steel
- Flood Sensor: SentryPlus Alert® Technology
- Installation Pattern: Horizontal N pattern
- Maximum Working Pressure: 175 PSI
- Temperature Range: 33°F to 140°F
Description
Description
Help Me Connect
Help Me Connect
Connections and Flood Sensor Activation
This 10 inch reduced pressure detector backflow preventer assembly is designed for horizontal N pattern installation using groove fittings for integral pipeline connection and adjustment. The assembly includes outside stem and yoke (OSY) resilient seated gate valves for shutoff control.
The integrated flood sensor with SentryPlus Alert® technology requires an add-on sensor connection kit to be fully activated and communicate. Connection kit options include those for BMS (Building Management Systems), cellular communication, or the Sensor Control Monitor which enables integration with BAS via RS-485 Modbus or the Nexa® platform via Wi-Fi. Without an add-on connection kit, the flood sensor acts as a passive component and will not relay alerts.
The assembly also features a cubic feet per minute meter for bypass monitoring, helping to detect leaks or unauthorized water usage within the fire sprinkler system. Each gate valve on the OS&Y model includes an option for an integrated supervisory switch.

Collapsible content
Additional Details
The Ames Fire & Waterworks Colt™ 10 inch Reduced Pressure Detector Backflow Preventer Assembly is designed to prevent the reverse flow of non-potable water and fire protection substances into the potable water supply due to backsiphonage or backpressure.
This compact modular assembly features a 304 stainless steel body and is approved for horizontal N pattern installation. It includes outside stem and yoke (OSY) resilient seated gate valves and a cubic feet per minute meter for detecting leaks and unauthorized water use.
Flood Sensor Technology
- Equipped with a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve.
- Requires an add-on sensor connection kit for activation, enabling relay alerts for potential flooding events.
- Connection kit options include BMS, cellular communication, or the Sensor Control Monitor for integration with BAS via RS-485 Modbus or the Nexa® platform via Wi-Fi.
Construction & Features
- Extremely compact design, approximately 70% lighter than traditional designs.
- Housing and sleeve constructed from 304 (Schedule 40) stainless steel.
- Features a quick access sleeve, torsion spring check valves, and lead-free bronze body test cocks.
- Corrosive resistant bottom-mounted pressure relief valve.
- Groove fittings for integral pipeline adjustment and ease of serviceability.
- Patented link check for lowest pressure loss.
- Reversible silicone or EPDM check disc rubber for durability.
- Includes an integrated supervisory switch as an option on each gate valve.
It is illegal to use this product in a plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States without consulting local water authority, building, and plumbing codes. The use of the flood sensor does not replace the need to comply with all required instructions, codes, and regulations related to installation, operation, and maintenance of this product, including proper drainage in the event of a discharge.
Specifications
General
- Product Type: Reduced Pressure Detector Backflow Preventer Assembly
- Series: C500N
- Nominal Size: 10 inch
- Installation Pattern: Horizontal N pattern
- Shutoff Valves: Outside Stem and Yoke (OSY) Resilient Seated Gate Valves
- Bypass Meter: Cubic Feet per Minute Meter
- Temperature Range: 33°F - 140°F (0.5°C - 60°C)
- Maximum Working Pressure: 175 PSI (12.1 bar)
Materials
- Housing & Sleeve: 304 (Schedule 40) Stainless Steel
- Elastomers: EPDM, Silicone, Buna 'N'
- Link Checks: Noryl®, Stainless Steel
- Check Discs: Reversible Silicone or EPDM
- Test Cocks: Lead Free* Bronze Body
- Pins & Fasteners: 300 Series Stainless Steel
- Springs: Stainless Steel
- Relief Valve: Bottom-mounted Cast Stainless Steel
Flood Sensor
- Sensor Technology: SentryPlus Alert®
- Flood Detection: Detects excessive water discharge from relief valve
- Activation: Requires add-on sensor connection kit
Certificates & Approvals
- Approved By: Foundation for Cross-Connection Control and Hydraulic Research at USC (FCCCHR-USC)
- Certification: AWWA C511-97
- Certification: ASSE 1047
- Certification: CSA B64.4
- Certification: UL Classified
- Certification: FM Approved
Dimensions & Weight (Approximate)
- Overall Length (A): 57 3/4 inch (1467 mm)
- C (OSY) Length: 45 3/4 inch (1162 mm)
- G Dimension: 66 inch (1676 mm)
- H Dimension: 49 1/2 inch (1257 mm)
- J Dimension: 32 1/2 inch (826 mm)
- M Dimension: 17 5/16 inch (440 mm)
- P Dimension: 44 1/2 inch (1124 mm)
- Weight: 893 lb (405 kg)
FAQs
What is the primary function of the Ames Colt™ C500N-OSY-C-FS backflow preventer?
What type of shutoff valves are included with this assembly?
How does the flood sensor function, and what is required to activate its alert features?
What is the maximum operating pressure and temperature range for this backflow preventer?
What material is used for the housing and sleeve of the C500N-OSY-C-FS assembly?
Related Products
-
-
Item Number: 7019628
Ames® 2 1/2" –10" 400/500 Lead Free Air Gap Drain Fitting w/ Splash Guard
Regular price $253.88Limited Stock