10 LF957RPDA-OSY-GPM-FS

Item Number: F124737
Skip to product information
1 of 1
Regular price $28,168.73
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Watts

  • Size: 10 inch
  • Weight: 997.0 lb
  • Construction: Lead Free
  • Housing Material: 304 (Schedule 40) Stainless Steel
  • Shutoff Valves: UL/FM Approved OSY Resilient Seated Gate Valves
  • Flood Sensor: SentryPlus Alert® Flood Detection
  • Max Operating Pressure: 175 PSI
  • Temperature Range: 33°F - 110°F
  • Bypass: Metered for Leak/Theft Detection

Description

This 10 inch Lead Free Reduced Pressure Detector Backflow Preventer Assembly safeguards potable water systems from contamination due to backpressure or backsiphonage. Featuring a compact and lightweight design approved for horizontal installation, it includes a SentryPlus Alert® flood sensor to detect relief valve discharge and prevent flooding. Constructed with a 304 stainless steel housing, UL/FM approved OSY gate valves, and a metered bypass for leak detection, it operates at a maximum of 175 PSI within a 33°F to 110°F temperature range. Item number F124737.

Help Me Connect

Connections

  • This 10 inch Reduced Pressure Detector Backflow Preventer Assembly features a main housing constructed with groove end connections, allowing for integral pipeline adjustment.
  • The assembly is equipped with Outside Stem and Yoke (OSY) resilient seated gate valves, which connect to these grooved ends. While various connection options for OSY valves are available, the visual reference indicates this specific assembly typically features flanged OSY valves connecting to the main body's grooved ends.
View full details

Collapsible content

Additional Details

The 10 inch Lead Free Reduced Pressure Detector Backflow Preventer Assembly provides crucial protection for potable water systems against contamination from backpressure and backsiphonage, particularly where health hazards may exist. Its extremely compact design is up to 70% lighter than traditional models and is approved for horizontal installation.

This assembly integrates a SentryPlus Alert® flood sensor to detect excessive water discharges from the relief valve, helping to prevent costly flooding. When paired with an optional add-on connection kit, the sensor activates to relay alerts to facility personnel through various communication methods, including BMS, cellular networks, or integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.

Construction & Components

  • Housing and sleeve constructed from 304 (Schedule 40) stainless steel for durability and corrosion resistance.
  • Features two independent torsion spring check modules with patented torsion spring design for lowest pressure loss.
  • Equipped with UL Classified and FM Approved outside stem and yoke (OSY) resilient seated gate valves.
  • Includes a corrosive resistant bottom mounted pressure relief valve.
  • A metered bypass is furnished to detect underground leaks, unauthorized water use, or theft of water from fire sprinkler systems.
  • Designed for unmatched ease of serviceability with replaceable check disc rubber.
  • Groove fittings allow for integral pipeline adjustment.
An add-on connection kit is required to activate the flood sensor's communication features; without it, the sensor operates passively.

Specifications

  • Product Type: Reduced Pressure Detector Backflow Preventer Assembly
  • Size: 10 inch
  • Construction: Lead Free*
  • Housing & Sleeve Material: 304 (Schedule 40) Stainless Steel
  • Shutoff Valves: UL Classified and FM Approved OSY Resilient Seated Gate Valves
  • Relief Valve: Bottom Mounted, Cast Stainless Steel, Corrosive Resistant
  • Checks: Patented Torsion Spring Check Modules
  • Check Disc Material: Reversible Silicone or EPDM
  • Bypass: Metered (Gallons per Minute)
  • Flood Sensor: SentryPlus Alert® Technology
  • Elastomer Materials: EPDM, Silicone, Buna 'N'
  • Torsion Spring Check Materials: Noryl®, Stainless Steel
  • Test Cock Material: Lead Free* Bronze Body
  • Pins & Fastener Material: 300 Series Stainless Steel
  • Spring Material: Stainless Steel
  • Maximum Working Pressure: 175 PSI (12.1 bar)
  • Temperature Range: 33°F - 110°F (0.5°C - 43°C)

Certificates & Approvals

  • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
  • AWWA C511-97
  • ASSE 1047
  • CSA B64.4
  • UL Classified (for BFG & OSY Only)
  • FM Approved (for BFG & OSY Only)
  • NSF Certified to NSF/ANSI 372

FAQs

What is the primary function of the 10 LF957RPDA-OSY-GPM-FS backflow preventer?

Its primary function is to protect potable water systems from contamination caused by backpressure or backsiphonage, particularly in health hazard applications. It also monitors for unauthorized water use.

How does the integrated flood sensor work, and what are its capabilities?

The assembly includes a SentryPlus Alert® flood sensor on the relief valve to detect excessive water discharges. With an add-on connection kit, it can relay alerts to facility personnel via BMS, cellular networks, or BAS integration (Modbus/Nexa® Wi-Fi) to prevent flooding.

What materials are primarily used in the construction of this backflow assembly?

The housing and sleeve are made from 304 (Schedule 40) stainless steel. Elastomers include EPDM, silicone, and Buna 'N', while test cocks are Lead Free* bronze. Springs and pins are stainless steel.

What are the maximum operating pressure and temperature limitations for this unit?

This backflow preventer is designed for a maximum working pressure of 175 PSI (12.1 bar) and can operate within a temperature range of 33°F to 110°F (0.5°C to 43°C).

What type of shutoff valves are included with this assembly?

The assembly comes with UL Classified and FM Approved outside stem and yoke (OSY) resilient seated gate valves, which are known for their reliability and ease of operation.