10 LFM500-OSY-GPM

Item Number: 0124788
Skip to product information
1 of 1
Regular price $53,815.50
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Size: 10 inch
  • Weight: 998.0 lb
  • Lead Free Reduced Pressure Detector Backflow Preventer
  • 304 (Schedule 40) Stainless Steel body and sleeve
  • OSY Shutoff Valves for reliable operation
  • Includes Gallon Per Minute (GPM) meter for leak detection
  • Maximum Working Pressure: 175 psi
  • Temperature Range: 33°F - 110°F
  • UL Classified, FM Approved, NSF Approved

Description

The 10 inch Lead Free Reduced Pressure Detector Backflow Preventer Assembly, LFM500-OSY-GPM, is designed to protect potable water supplies from contamination caused by backsiphonage and backpressure. It is constructed from durable 304 (Schedule 40) stainless steel and features OSY shutoff valves. This assembly is ideal for fire protection systems and other health hazard cross-connections. A built-in gallon per minute meter helps detect leaks and unauthorized water usage. With a maximum working pressure of 175 psi and a compact design, it offers reliable performance and easy maintenance. Item number 0124788.

Help Me Connect

Configurations & Connections

  • The assembly can be installed in horizontal or N pattern installations.
  • It features groove fittings to allow for integral pipeline adjustment, simplifying installation in various piping systems.
  • The OSY (Outside Stem and Yoke) resilient seated gate valves provide reliable shut-off capabilities.
  • Connections are designed for compatibility with standard 10 inch piping systems, as indicated by the product size.
View full details

Collapsible content

Additional Details

This Maxim™ 10 inch lead free reduced pressure detector backflow preventer assembly is designed to prevent the reverse flow of fire protection substances and water of non-potable quality into the potable water supply. It protects against backsiphonage and backpressure in accordance with national plumbing codes and water authority requirements.

Ideal for protection at cross-connections identified as health hazards, such as on fire sprinkler systems and from other contaminants found at the service line entrance, this compact modular assembly ensures the safety of your water supply. The unit is furnished with a gallon per minute meter to detect underground leaks and unauthorized water use.

Features

  • Prevents the reverse flow of fire protection substances and non-potable water
  • Compact design, approximately 70% lighter than traditional models
  • Valve body and closure sleeve manufactured from 304 (Schedule 40) stainless steel
  • Features drip tight shutoff valves and a quick access sleeve for easy maintenance
  • Includes a gallon per minute meter for leak detection and monitoring unauthorized water use
  • Equipped with torsion spring check valves, outside stem and yoke (OSY) resilient seated gate valves, test cocks, and a corrosive resistant bottom mounted pressure relief valve
  • Groove fittings allow for integral pipeline adjustment
  • Prevents Link Check provides lowest pressure loss
  • Offers uninterrupted ease of serviceability with a single access cover
  • Available for horizontal or N pattern installations
  • Equipped with bronze body nickel plated test cocks and replaceable check disc rubber

Specifications

  • Product Series: LFM500, LFM500N, LFM500Z
  • Nominal Size: 10 inch
  • Valve Body Material: 304 (Schedule 40) Stainless Steel
  • Closure Sleeve Material: 304 (Schedule 40) Stainless Steel
  • Shutoff Valves: OSY (Outside Stem and Yoke) Resilient Seated Gate Valves
  • Check Valve Type: Torsion Spring
  • Check Modules: Independent Link Check
  • Link Checks Material: Noryl®, Stainless Steel
  • Check Discs: Reversible Silicone or EPDM®
  • Test Cocks: Lead Free* Cast Copper Silicon Alloy, Bronze Body Nickel Plated
  • Pins & Fasteners Material: Series Stainless Steel
  • Springs Material: Stainless Steel
  • Pressure Relief Valve: Corrosive resistant, bottom mounted
  • Elastomers: EPDM, Silicone, Buna 'N'
  • Temperature Range: 33°F - 110°F (5°C – 43°C)
  • Maximum Working Pressure: 175 psi (12.06 bar)
  • Lead Content: Wetted surface less than 0.25% by weight

Certificates & Approvals

  • Approved by Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
  • AWWA C511-97
  • ASME C
  • CSA B64.4
  • UL Classified
  • FM Approved
  • NSF Approved

Dimensions & Weight (Approximate)

  • Weight (LFM500 M500): 798 lbs (362 kgs)

FAQs

What is the primary function of this backflow preventer assembly?

This Maxim™ 10 inch lead free reduced pressure detector backflow preventer assembly is designed to prevent the reverse flow of fire protection substances and water of non-potable quality from entering the potable water supply, protecting against backsiphonage and backpressure.

What material is used for the valve body and closure sleeve?

The entire valve body and closure sleeve are manufactured from durable 304 (Schedule 40) stainless steel, providing robust construction and corrosion resistance.

Does this assembly include a flow meter?

Yes, this backflow preventer assembly comes furnished with a gallon per minute (GPM) meter, which is used to detect underground leaks and monitor for unauthorized water use.

What type of shutoff valves are included with this assembly?

The assembly is equipped with OSY (Outside Stem and Yoke) resilient seated gate valves, which are known for their reliability and ease of operation in fire protection systems.

What are the certifications and approvals for this product?

This backflow preventer assembly is approved by the Foundation for Cross-Connection Control and Hydraulic Research (FCCCHR-USC), AWWA C511-97, ASME C, CSA B64.4, UL Classified, FM Approved, and NSF Approved.