2 1/2 C300N-BFG-GPM

Item Number: 0191266
Skip to product information
1 of 1
Regular price $7,861.50
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Size: 2 1/2 inch
  • Weight: 129.0 lb
  • Assembly Type: Double Check Detector Backflow Preventer
  • Housing & Sleeve: 304 (Schedule 40) Stainless Steel
  • Valves: Grooved Gear Operated Butterfly with Tamper Switch
  • Checks: Patented Tri-Link Check
  • Bypass: Gallons per Minute (GPM) Meter
  • Maximum Operating Pressure: 175 PSI
  • Installation: Horizontal, Vertical, or N-Pattern

Description

This 2 1/2 inch Colt C300N-BFG Double Check Detector Backflow Preventer Assembly protects potable water supplies from dangerous cross-connections involving non-potable water in non-health hazard applications, such as fire sprinkler systems. Constructed with 304 stainless steel housing and sleeve, it offers superior corrosion resistance and strength. Key features include patented Tri-Link Checks for low pressure loss, grooved gear-operated butterfly valves with tamper switches, and a gallons per minute bypass meter for leak detection. Its compact design allows for installation in horizontal, vertical, or N patterns. Approved by AWWA C510-97, ASSE 1048, CSA B64.5, UL, and FM, it operates at up to 175 PSI and temperatures from 33°F to 140°F.

Help Me Connect

This Colt Series C300N-BFG Double Check Detector Backflow Preventer is designed for versatile pipeline integration. It features grooved end connections, allowing for efficient and secure attachment to compatible grooved piping systems. The assembly is approved for installation in horizontal, vertical, or N pattern configurations, providing flexibility to meet diverse site requirements and flow directions as indicated by the flow arrow on the assembly.

View full details

Collapsible content

Additional Details

This Colt™ 2 1/2 inch double check detector backflow preventer assembly is designed to protect drinking water supplies from dangerous cross-connections, preventing the reverse flow of non-potable water into the potable water supply due to backsiphonage or backpressure. It is primarily used for non-health hazard applications, such as on fire sprinkler systems where monitoring unauthorized water use is necessary.

Key Features

  • Extremely compact design, up to 70% lighter than traditional assemblies.
  • Constructed with a 304 (Schedule 40) stainless steel housing and sleeve for long-term corrosion protection and maximum strength.
  • Features patented Tri-Link Check modules that provide the lowest pressure loss and unmatched ease of serviceability.
  • Groove fittings allow for integral pipeline adjustment during installation.
  • Equipped with grooved gear-operated butterfly valves with tamper switches.
  • Includes a gallon per minute meter to detect underground leaks and unauthorized water use.
  • Suitable for horizontal, vertical, or N pattern installations.
  • Check discs are replaceable.

Components

  • Two independent Tri-Link Check modules
  • Single housing with access sleeve
  • Four test cocks
  • Two drip-tight shutoff valves
  • Bypass assembly with a meter (registers in gallon or cubic measurement) and a double check valve assembly
  • Integrated supervisory tamper switch on butterfly valves


WARNING: It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes.

Specifications

  • Size: 2 1/2 inch
  • Assembly Type: Double Check Detector Backflow Preventer
  • Housing & Sleeve Material: 304 (Schedule 40) Stainless Steel
  • Check Valve Type: Patented Tri-Link Check
  • Elastomers: EPDM, Silicone, Buna 'N'
  • Check Disc Material: Reversible Silicone or EPDM
  • Test Cocks Material: Lead Free* Bronze Body
  • Pins & Fasteners Material: 300 Series Stainless Steel
  • Springs Material: Stainless Steel
  • Shutoff Valves: Grooved Gear Operated Butterfly Valves with Tamper Switch
  • Bypass Meter: Gallons/Minute Meter
  • Maximum Working Pressure: 175 PSI (12.1 bar)
  • Temperature Range: 33°F to 140°F (0.5°C to 60°C)
  • Installation Patterns: Horizontal, Vertical, N Pattern

Certificates & Approvals

  • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at USC (FCCCHR-USC)
  • AWWA C510-97
  • ASSE 1048
  • CSA B64.5
  • UL Classified
  • FM Approved

FAQs

What is the primary purpose of this backflow preventer assembly?

This assembly is designed to protect drinking water supplies by preventing the reverse flow of non-potable water, often used in fire protection systems or industrial processing, from contaminating the potable water supply due to backsiphonage or backpressure.

What type of installation patterns are supported by this device?

This backflow preventer assembly is approved for horizontal, vertical, and "N" pattern installations, offering flexibility to suit various piping configurations.

What materials are used for the main housing and internal components?

The main housing and sleeve are constructed from 304 (Schedule 40) stainless steel for durability and corrosion resistance. The Tri-Link checks incorporate Noryl® and stainless steel, with reversible silicone or EPDM discs.

Does this backflow preventer include a meter for water usage?

Yes, this assembly is furnished with a bypass assembly that includes a gallons per minute (GPM) meter, which helps monitor unauthorized water use and detect underground leaks.

What are the key certifications and approvals for this Colt C300N series assembly?

This assembly is approved by the Foundation for Cross-Connection Control and Hydraulic Research at USC, AWWA C510-97, ASSE 1048, CSA B64.5, UL Classified, and FM Approved, ensuring compliance with industry standards.