2 1/2 LF009-LF-FS

Item Number: F122642
Skip to product information
1 of 1
Regular price $6,587.26
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Watts

  • 2 1/2 inch Reduced Pressure Zone Backflow Preventer
  • Lead Free cast iron body construction
  • ArmorTek® advanced epoxy coating for corrosion resistance
  • SentryPlus Alert® flood sensor for discharge detection
  • NPT inlet and outlet connections
  • Modular check construction for easy maintenance
  • Max Supply Pressure: 175 PSI
  • Max Water Temperature (Continuous): 110°F

Description

This WATTS 2 1/2 inch Lead Free Reduced Pressure Zone Backflow Preventer Assembly (LF009-LF-FS) protects potable water from contamination due to backsiphonage and backpressure in continuous pressure piping systems. Its cast iron body features ArmorTek® advanced epoxy coating for superior corrosion resistance, ensuring long-term durability. Designed without shutoff valves, it integrates easily into existing systems using NPT connections. A SentryPlus Alert® flood sensor provides early detection of relief valve discharges, and with an optional connection kit, can send alerts to facility personnel. This model offers modular construction for simplified maintenance and adheres to critical lead-free and industry standards.

Help Me Connect

The WATTS 2 1/2 inch LF009-LF-FS Reduced Pressure Zone Backflow Preventer Assembly is designed for direct installation into piping systems using its NPT inlet and outlet connections. This model does not include shutoff valves, requiring separate isolation valves to be installed upstream and downstream if required by local codes or application needs.

For enhanced monitoring, the integrated SentryPlus Alert® flood sensor can be activated by purchasing an add-on sensor connection kit (sold separately). These kits enable the sensor to communicate flood alerts via BMS (Building Management System) or cellular networks, providing early notification of excessive water discharge from the relief valve.

View full details

Collapsible content

Additional Details

The WATTS 2 1/2 inch Lead Free Reduced Pressure Zone Backflow Preventer Assembly is designed to protect potable water supplies from contamination due to backsiphonage and/or backpressure.

This assembly is ideal for use in continuous pressure piping applications and at cross-connections identified as health hazards, ensuring water safety in commercial and industrial settings.

Construction and Coating

  • Features a robust cast iron body construction, engineered for durability in demanding environments.
  • Utilizes ArmorTek® coating technology, a patented three-part advanced epoxy system, to provide integrated protection against microbial-induced corrosion (MIC) and other exposed metal substrate corrosion, extending the product's lifespan.
  • Constructed as Lead Free* to comply with lead-free installation requirements, ensuring the wetted surface contains less than 0.25% lead by weight.

Backflow Prevention System

  • Equipped with two in-line, independent check valves, captured springs, and replaceable check seats to reliably prevent backflow.
  • An internal relief valve is included, designed for reduced space requirements and enhanced safety.
  • Features NPT inlet and outlet connections for straightforward installation into existing piping systems.
  • Designed with a single access cover and modular check construction for ease of maintenance and economical repair with replaceable seats.

Advanced Flood Detection

  • Includes a flood sensor with SentryPlus Alert® technology, installed on the relief valve, to detect excessive water discharges.
  • When activated with an add-on sensor connection kit (sold separately), the flood sensor can send alerts to facility personnel via BMS (Building Management System) or cellular communication, helping to prevent costly flooding and damage.

Important Safety Information: An add-on connection kit is required to activate the flood sensor's alert features. Without this kit, the sensor is a passive component and does not communicate with other devices. The flood sensor does not replace the need to comply with all required installation instructions, codes, and regulations. Watts is not responsible for alert failures due to connectivity issues, power outages, or improper installation.

Specifications

General

  • Product Type: Reduced Pressure Zone Backflow Preventer Assembly
  • SKU: F122642
  • Brand: WATTS
  • Model Series: LF009
  • Size: 2 1/2 inch
  • Valve Type: No Shutoff Valves (-LF suffix)
  • Body Construction: Cast Iron (for 2 1/2" - 3" sizes)
  • Body Coating: ArmorTek® Advanced Epoxy System
  • Lead Free: Yes (wetted surface contains less than 0.25% lead by weight)

Performance

  • Maximum Supply Pressure: 175 PSI (12.1 bar)
  • Continuous Water Temperature: 110°F (43°C)
  • Intermittent Water Temperature: 140°F (60°C)

Components & Features

  • Check Valves: Two in-line, independent
  • Relief Valve: Internal pressure differential
  • Check Seats: Replaceable polymer
  • Springs: Captured
  • Test Cocks: Yes (ball valve type)
  • Flood Detection: SentryPlus Alert® technology flood sensor on relief valve (requires add-on kit for alerts)
  • Maintenance Access: Single access cover, modular check construction, top entry to all internals

Connections

  • Inlet Connection: NPT
  • Outlet Connection: NPT

Certifications & Standards

  • ASSE Standard: 1013
  • AWWA Standard: C511
  • CSA Standard: B64.4
  • IAPMO File No.: 1563
  • USC Approval: Yes (Foundation for Cross-Connection Control and Hydraulic Research)
  • UL Classified: No (This model has no shutoff valves)
  • FM Approved: No (This model has no shutoff valves)

FAQs

What is the primary purpose of the WATTS LF009-LF-FS backflow preventer?

Its primary purpose is to protect potable water supplies from contamination caused by backsiphonage or backpressure, typically in continuous pressure piping applications and at health hazard cross-connections.

Does this model include shutoff valves?

No, this specific LF009-LF-FS model is designed without shutoff valves. Isolation valves would need to be installed separately upstream and downstream if required by your application or local codes.

How does the ArmorTek® coating benefit the backflow preventer?

The ArmorTek® coating is a patented three-part advanced epoxy system that protects the cast iron body and internal components from microbial-induced corrosion (MIC) and other forms of metal substrate corrosion, extending the product's lifespan.

How does the SentryPlus Alert® flood sensor work?

The flood sensor detects excessive water discharges from the relief valve. To activate its alert features, an add-on sensor connection kit (sold separately) is required, which enables notifications via BMS or cellular communication. Without the kit, the sensor is passive.

What are the connection types for installation?

This backflow preventer assembly features NPT (National Pipe Taper) inlet and outlet connections for integration into your piping system.