2 1/2 M500Z-BFG-GPM

Item Number: 0191158
Skip to product information
1 of 1
Regular price $12,352.49
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Nominal Size: 2 1/2 inch
  • Weight: 132.0 lb
  • Housing Material: 304 (Schedule 40) Stainless Steel
  • Maximum Working Pressure: 175 PSI
  • Approved for Z Pattern Horizontal Installation
  • Includes Gallon Per Minute (GPM) meter
  • UL and FM grooved gear operated butterfly shutoffs
  • Certifications: ASSE 1047, CSA B64.4, cULus, FM Approved
  • Extremely compact and lightweight design

Description

The 2 1/2 inch Maxim M500Z Reduced Pressure Detector Backflow Preventer Assembly protects potable water supplies from cross-contamination with non-potable substances, commonly found in fire sprinkler systems and industrial applications. This assembly features a compact, lightweight 304 stainless steel housing and is approved for Z pattern horizontal installations. It includes UL and FM grooved gear operated butterfly shutoff valves and a gallon per minute (GPM) meter for detecting leaks and unauthorized water usage. With a maximum operating pressure of 175 PSI, this unit is certified to ASSE 1047, CSA B64.4, cULus, and FM standards.

Help Me Connect

Connections

  • This assembly features grooved end connections for easy installation and integral pipeline adjustment.
  • The grooved gear operated butterfly shutoff valves are suitable for connection to corresponding grooved piping systems.
View full details

Collapsible content

Additional Details

The Ames Maxim™ M500Z Reduced Pressure Detector Backflow Preventer Assembly, 2 1/2 inch, is designed to protect drinking water supplies from dangerous cross-connections in accordance with national plumbing codes and water authority requirements.

It is ideal for health-hazard non-potable service applications such as fire sprinkler systems and industrial processing, and helps monitor unauthorized water use from fire protection systems.

Key Features

  • Extremely Compact Design, approximately 70% lighter than traditional models
  • 304 (Schedule 40) Stainless Steel housing and sleeve for durability
  • Groove Fittings allow integral pipeline adjustment and easy installation
  • Patented Link Check provides lowest pressure loss
  • Unmatched Ease of Serviceability with a single access cover for maintenance
  • Available with UL and FM grooved gear operated butterfly valve shutoffs with tamper switch
  • Approved for Horizontal or Z Pattern Installations
  • Furnished with a gallon per minute meter to detect underground leaks and unauthorized water use
  • Replaceable Check Disc Rubber for extended life

Construction Details

  • Entire valve body and closure sleeve constructed from 304 (Schedule 40) stainless steel
  • Two independent Link Check modules with reversible elastomer discs
  • Differential pressure relief valve, bottom mounted, constructed from stainless steel
  • Bronze body nickel plated test cocks
  • Shutoff valves are UL/FM grooved gear operated butterfly valves with tamper switch

A WARNING: It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes.

Specifications

General

  • Product Type: Reduced Pressure Detector Backflow Preventer Assembly
  • Series: Maxim™ M500Z
  • Nominal Size: 2 1/2 inch
  • Configuration: Z pattern horizontal installation
  • Shutoff Valves: Grooved Gear Operated Butterfly Valves with Tamper Switch
  • Meter: Gallon per minute (GPM)

Materials

  • Housing & Sleeve: 304 (Schedule 40) Stainless Steel
  • Elastomers: EPDM, Silicone, Buna 'N'
  • Link Checks: Noryl®, Stainless Steel, Torsion Spring Check Modules
  • Check Discs: Reversible Silicone or EPDMr
  • Test Cocks: Lead Free* Bronze Body, Nickel Plated
  • Pins & Fasteners: 300 Series Stainless Steel
  • Springs: Stainless Steel
  • Relief Valve: Stainless Steel (bottom mounted)

Performance

  • Maximum Working Pressure: 175 PSI (12.06 bar)
  • Temperature Range: 33°F - 110°F (5°C - 43°C)

Certificates & Approvals

  • ASSE 1047
  • CSA B64.4
  • cULus Classified
  • FM Approved
  • AWWA C511-97

FAQs

What is the primary function of the Maxim M500Z backflow preventer?

This assembly is designed to protect drinking water supplies from dangerous cross-connections with non-potable sources, such as fire protection systems or industrial processing. It prevents the reverse flow of contaminants due to backpressure or backsiphonage.

What are the installation requirements for this backflow preventer?

The 2 1/2 inch Maxim M500Z assembly is approved for both horizontal and Z pattern installations. It features grooved end connections for ease of integration into piping systems.

What materials are used in the construction of this backflow preventer?

The main housing and closure sleeve are made from 304 (Schedule 40) stainless steel. It also incorporates Noryl and stainless steel link checks, reversible silicone or EPDM check discs, and Lead Free* bronze body nickel plated test cocks.

What certifications does the Maxim M500Z assembly hold?

This backflow preventer is certified by ASSE 1047, CSA B64.4, cULus Classified, and is FM Approved. It also meets AWWA C511-97 standards.

Why does this backflow preventer include a gallon per minute (GPM) meter?

The integrated GPM meter allows for the detection of underground leaks and helps monitor for unauthorized water usage within the fire protection system.