2.5 C400Z-BFG-FS

Item Number: F0191480
Skip to product information
1 of 1
Regular price $7,372.50
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Nominal Size: 2 1/2 inch
  • Weight: 90.0 lb
  • Housing Material: Type 304 Stainless Steel
  • Configuration: Z Pattern Horizontal
  • Valve Type: Grooved Gear Operated Butterfly Valves with Tamper Switch
  • Maximum Working Pressure: 175 psi
  • Flood Sensor: Integrated SentryPlus Alert® Technology
  • Lead Free Construction
  • Compact Design, 70% lighter than traditional models
  • Approvals: ASSE 1013, CSA B64.4, UL, FM, NSF

Description

The 2.5 inch Ames C400Z-BFG-FS Lead Free Reduced Pressure Zone Backflow Preventer protects potable water systems from contamination due to backsiphonage and backpressure. It features a robust Type 304 stainless steel body, torsion spring check modules, and grooved gear operated butterfly valves with a tamper switch, configured for Z pattern horizontal installation. An integrated SentryPlus Alert flood sensor detects relief valve discharge, which can be activated for smart alerts with an optional connection kit. This assembly is approved by ASSE 1013, CSA B64.4, UL, FM, and NSF, ensuring reliable performance in health hazard applications.

Help Me Connect

Installation & Connections

  • This backflow preventer is approved for horizontal Z pattern installation, provided it is installed in accordance with the direction of the flow arrow.
  • Features groove couplings for easy installation and precise pipe alignment.

Flood Sensor Connectivity

  • The integrated flood sensor requires an add-on connection kit (sold separately) to activate its alert capabilities.
  • Connection kits offer various communication options, including BMS, cellular, or the Sensor Control Monitor for integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.
View full details

Collapsible content

Additional Details

This Colt 2 1/2 inch lead free reduced pressure zone backflow preventer assembly is designed to protect potable water systems from contamination caused by backsiphonage or backpressure from non-potable sources. It is approved for horizontal Z pattern installation and is ideal for continuous pressure piping applications and at cross-connections identified as health hazards.

Design & Construction

  • Features an extremely compact design that is approximately 70% lighter than traditional designs.
  • Constructed with a Type 304 (Schedule 40) stainless steel housing and sleeve.
  • Includes torsion spring check modules for unmatched ease of serviceability and a patented link check for lowest pressure loss.
  • Equipped with grooved gear operated butterfly valves with tamper switch and test cocks.
  • Uses groove fittings for integral pipeline adjustment during installation.
  • The replaceable check disc rubber ensures long-term performance.

Flood Detection System

  • Includes an integrated flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve.
  • When paired with an add-on connection kit (sold separately), the sensor activates to relay alerts for potential flooding events.
  • Connection kit options include BMS, cellular communication, and the Sensor Control Monitor, enabling integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.

An add-on connection kit is required to activate the flood sensor. Without the connection kit, the flood sensor is a passive component and will not communicate with any other device.

Specifications

  • Product Type: Reduced Pressure Zone Backflow Preventer
  • Nominal Size: 2 1/2 inch
  • Assembly Series: C400
  • Configuration: Z Pattern Horizontal
  • Valve Type: Grooved Gear Operated Butterfly Valves with Tamper Switch
  • Flood Sensor: Integrated with SentryPlus Alert® Technology

Materials

  • Housing & Sleeve: Type 304 (Schedule 40) Stainless Steel
  • Elastomers: EPDM, Silicone, Buna 'N'
  • Link Checks: Noryl®, Stainless Steel
  • Check Discs: Reversible Silicone or EPDM
  • Test Cocks: Lead Free* Bronze Body
  • Pins & Fasteners: 300 Series Stainless Steel
  • Springs: Stainless Steel

Performance & Design

  • Design: Extremely compact
  • Weight: Approximately 70% lighter than traditional designs
  • Temperature Range: 33°F - 140°F (0.5°C - 60°C)
  • Maximum Working Pressure: 175 psi (12.1 bar)
  • Lead Free: Yes (wetted surfaces contain less than 0.25% lead by weight)

Certificates & Approvals

  • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
  • AWWA C511-97
  • ASSE 1013
  • CSA B64.4
  • UL Classified (BFG & OSY Only)
  • FM Approved (BFG & OSY Only)
  • NSF Certified to NSF/ANSI 61-G

FAQs

What is the primary purpose of the 2.5 C400Z-BFG-FS backflow preventer?

Its primary purpose is to protect potable water systems from contamination by preventing the reverse flow of non-potable substances due to backsiphonage or backpressure.

What materials are used for the main housing and sleeve of this assembly?

The main housing and sleeve are constructed from Type 304 (Schedule 40) stainless steel for durability and corrosion resistance.

Does this backflow preventer come with a flood detection system?

Yes, it includes an integrated flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. An add-on connection kit is required to activate its alert functionality.

What are the key certifications and approvals for this C400Z assembly?

This assembly is approved by FCCCHR-USC, AWWA C511-97, ASSE 1013, CSA B64.4, UL Classified, FM Approved, and NSF Certified to NSF/ANSI 61-G.

What is the maximum operating pressure and temperature range for this unit?

The maximum working pressure is 175 psi (12.1 bar), and the temperature range is 33°F - 140°F (0.5°C - 60°C).