2.5 C500N-BFG-G-FS

Item Number: F0191464
Skip to product information
1 of 1
Regular price $9,620.25
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Size: 2 1/2 inch
  • Weight: 132.0 lb
  • Housing & Sleeve: 304 (Schedule 40) Stainless Steel
  • Maximum Working Pressure: 175 PSI
  • Temperature Range: 33°F - 140°F
  • Integrated Flood Sensor with SentryPlus Alert® technology
  • Grooved Gear Operated Butterfly Shutoffs with Tamper Switch
  • Horizontal N-Pattern Installation
  • Metered Bypass for Leakage and Theft Detection

Description

The Colt 2 1/2 inch C500N Reduced Pressure Detector Backflow Preventer Assembly protects potable water supplies from contamination caused by backsiphonage or backpressure. This compact, modular unit features a durable 304 stainless steel body, grooved gear operated butterfly shutoffs, and a gallon per minute meter for detecting unauthorized water use or leaks. It includes an integrated flood sensor with SentryPlus Alert® technology to detect excessive relief valve discharge, offering advanced monitoring capabilities for fire protection and industrial processing systems. Approved for horizontal N-pattern installation, it ensures reliable protection.

Help Me Connect

Connections

  • This reduced pressure detector assembly is designed for systems with 2 1/2 inch grooved connections.
  • The inlet and outlet utilize grooved gear operated butterfly valves with tamper switches, facilitating easy and integral pipeline adjustment.
  • Ensure compatibility with existing grooved piping systems for proper installation and operation.
View full details

Collapsible content

Additional Details

This Colt(TM) 2 1/2 inch reduced pressure detector backflow preventer assembly is designed to prevent the reverse flow of fire protection substances and water of non-potable quality from being pumped or siphoned into the potable water supply due to backsiphonage and or backpressure.

This compact modular design is approved for horizontal N pattern installation and consists of a 304 (Schedule 40) stainless steel body with a quick access sleeve, torsion spring check valves, and corrosive resistant bottom mounted pressure relief valve. It is furnished with a gallon per minute meter to detect underground leaks and unauthorized water use, and features grooved gear operated butterfly valves with tamper switches.

Flood Detection

  • Contains a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve.
  • When paired with an add-on connection kit (sold separately), the sensor activates to relay alerts for potential flooding events.
  • Connection kit options include BMS, cellular communication, and the Sensor Control Monitor, which enables integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.
  • A WARNING: It is illegal to use this product in a plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes.

Features

  • Extremely compact design, up to 70% lighter than traditional designs.
  • Groove fittings allow for integral pipeline adjustment and easy installation.
  • Patented link check ensures lowest pressure loss.
  • Unmatched ease of serviceability with replaceable check disc rubber.
  • Bottom-mounted cast stainless steel relief valve.
  • Integrated supervisory switch as an option on each gate valve of the OS&Y model.

Specifications

  • Size: 2 1/2 inch
  • Housing & Sleeve Material: 304 (Schedule 40) Stainless Steel
  • Elastomers: EPDM, Silicone, Buna 'N'
  • Link Checks Material: Noryl®, Stainless Steel
  • Check Discs: Reversible Silicone or EPDM
  • Test Cocks Material: Lead Free* Bronze Body
  • Pins & Fasteners Material: 300 Series Stainless Steel
  • Springs Material: Stainless Steel
  • Configuration: Horizontal N-Pattern
  • Shutoff Valves: Grooved Gear Operated Butterfly Valves with Tamper Switch
  • Maximum Working Pressure: 175 PSI (12.1 bar)
  • Temperature Range: 33°F - 140°F (0.5°C - 60°C)
  • Bypass: Metered (Gallons Per Minute)

Certificates & Approvals

  • Approved by Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
  • AWWA C511-97
  • ASSE 1047
  • CSA B64.4
  • UL Classified
  • FM Approved

FAQs

What is the primary use of the Colt 2 1/2 inch C500N backflow preventer?

This assembly is designed to protect drinking water supplies from contamination by preventing the reverse flow of non-potable water from fire protection, irrigation, or industrial processing systems due to backsiphonage or backpressure.

What are the key material specifications for this backflow preventer?

The housing and sleeve are constructed from 304 (Schedule 40) stainless steel. Elastomers include EPDM, silicone, and Buna 'N', while test cocks are made from Lead Free* bronze body.

Does this model include a flood sensor?

Yes, it includes a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. An add-on connection kit (sold separately) is required to activate alert relay functionality.

What type of shutoff valves are included with this assembly?

This model comes with UL Classified and FM Approved grooved gear operated butterfly valves, which also feature a tamper switch for enhanced security and monitoring.

What are the maximum operating pressure and temperature limits?

The assembly has a maximum working pressure of 175 PSI (12.1 bar) and an operating temperature range of 33°F to 140°F (0.5°C to 60°C).