2.5 LFC500Z-OSY-C-FS

Item Number: F0124653
Skip to product information
1 of 1
Regular price $9,217.50
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Size: 2.5 inch
  • Weight: 200.0 lb
  • Lead Free* Reduced Pressure Detector Assembly
  • Housing Material: Type 304 (Schedule 40) Stainless Steel
  • Shutoff Valves: OSY Resilient Seated Gate Valves
  • Installation Pattern: Horizontal Z Pattern
  • Flood Sensor: SentryPlus Alert® Technology
  • Bypass Meter: CFM for leakage detection
  • Maximum Working Pressure: 175 psi

Description

This 2.5 inch Lead Free Reduced Pressure Detector Backflow Preventer Assembly is designed to protect potable water systems from contamination due to backsiphonage and backpressure from fire protection substances and non-potable water. It features a Type 304 stainless steel housing, OSY resilient seated gate valves, and is approved for horizontal Z pattern installation. An integrated flood sensor with SentryPlus Alert® technology detects excessive water discharges from the relief valve, with an optional connection kit for remote alerts. A CFM meter helps identify leaks and unauthorized water use. This robust unit offers a maximum operating pressure of 175 psi.

Help Me Connect

Flood Sensor Connectivity

  • The integrated flood sensor with SentryPlus Alert® technology detects excessive water discharges from the relief valve.
  • An add-on connection kit is required to activate the flood sensor and enable communication.
  • Without a connection kit, the flood sensor acts as a passive component and will not communicate with other devices.
  • Connection kit options include those for Building Management Systems (BMS), cellular communication, and the Sensor Control Monitor for integration with BAS via RS‑485 Modbus or the Nexa® platform through Wi-Fi.
  • Retrofit sensor connection kits are also available for existing installations.
View full details

Collapsible content

Additional Details

This Colt™ 2 1/2 inch Lead Free Reduced Pressure Detector Backflow Preventer Assembly is designed to protect potable water systems from contamination by preventing the reverse flow of fire protection substances and non-potable water due to backsiphonage and backpressure.

The LFC500 series also monitors for unauthorized water use from the fire protection system, providing a comprehensive safety and security solution.

Key Features

  • Extremely compact design, making it 70% lighter than traditional designs.
  • Approved for horizontal Z pattern installation.
  • Includes outside stem and yoke (OSY) resilient seated gate valves.
  • Equipped with a metered bypass (CFM meter) to detect underground leaks and unauthorized water use from the fire sprinkler system.
  • Features a flood sensor with SentryPlus Alert® technology on the relief valve to detect excessive water discharges and potential flooding events.
  • Integrated supervisory switch is an option on each gate valve of the OSY model.

Construction

  • Housing and sleeve are manufactured from durable Type 304 (Schedule 40) stainless steel.
  • Features groove fittings for integral pipeline adjustment.
  • Contains two independent Link Check modules with reversible elastomer discs for drip-tight closure against reverse flow.
  • Test cocks are bronze body, nickel plated.
  • Elastomers include EPDM, silicone, and Buna-N.
  • Utilizes a corrosive resistant bottom-mounted pressure relief valve.

NOTICE: An add-on connection kit is required to activate the flood sensor. Without the connection kit, the flood sensor is a passive component and will not communicate with any other device. Use of the flood sensor does not replace the need to comply with all required instructions, codes, and regulations related to installation, operation, and maintenance of this product, including the need to provide proper drainage in the event of a discharge.

Specifications

  • Size: 2 1/2 inch
  • Backflow Preventer Type: Reduced Pressure Detector Assembly (RPDA)
  • Lead Free: Yes (Wetted surface contains less than 0.25% of lead by weight)
  • Housing & Sleeve Material: Type 304 (Schedule 40) Stainless Steel
  • Shutoff Valve Type: Outside Stem and Yoke (OSY) Resilient Seated Gate Valves
  • Bypass Meter: CFM (Cubic Feet Per Minute) Meter
  • Installation Pattern: Horizontal Z Pattern
  • Test Cock Material: Lead Free* Bronze body, Nickel Plated
  • Elastomers: EPDM, Silicone, Buna-N
  • Link Check Material: Noryl®, Stainless Steel
  • Check Disc Material: Reversible Silicone or EPDM
  • Pins & Fasteners: 300 Series Stainless Steel
  • Springs: Stainless Steel
  • Flood Sensor: SentryPlus Alert® Technology (on relief valve)

Performance

  • Temperature Range: 33°F - 110°F (0.5°C – 43°C)
  • Maximum Working Pressure: 175 psi (12.1 bar)

Certificates & Approvals

  • Approved by Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
  • AWWA C511-97
  • ASSE 1047
  • CSA B64.4
  • UL Classified
  • FM Approved (for OSY models)
  • NSF Certified to NSF/ANSI 372

FAQs

What is the primary function of the 2.5 inch LFC500Z-OSY-C-FS backflow preventer?

Its primary function is to protect potable water systems from contamination by preventing the reverse flow of fire protection substances and non-potable water due to backsiphonage and backpressure.

What does "Lead Free" mean for this specific product?

"Lead Free" indicates that the wetted surface of this product, which comes into contact with consumable water, contains less than 0.25% of lead by weight, complying with Lead Free* installation requirements.

How does the flood sensor feature work on this assembly?

The LFC500Z-OSY-C-FS includes a flood sensor with SentryPlus Alert® technology on the relief valve to detect excessive water discharges. When paired with an add-on connection kit, the sensor activates to relay alerts for potential flooding events.

What is the purpose of the CFM meter on this backflow preventer?

The CFM (Cubic Feet Per Minute) meter is a metered bypass assembly designed to detect underground leaks and monitor for unauthorized water use from the fire sprinkler system.

What are the installation pattern and shutoff valve types for this LFC500 series assembly?

This assembly is approved for horizontal Z pattern installation and is equipped with outside stem and yoke (OSY) resilient seated gate valves.