- Nominal Pipe Size: 2 inch
- Max. Working Pressure: 175 psi
- Temperature Range: 32°F to 140°F
- Body Material: Lead Free Cast Copper Silicon Alloy
- Features SentryPlus Alert® flood sensor
- Modular relief valve and check valves for easy maintenance
- Quarter turn shutoff ball valves
- Approvals: ASSE 1013, CSA B64.4, NSF/ANSI 61-G
Description
Description
This 2 inch FEBCO Lead Free Reduced Pressure Zone Backflow Preventer Assembly prevents the reverse flow of high-hazard fluids into potable water supplies. Constructed with a lead free cast copper silicon alloy body and quarter turn ball valves, it offers reliable protection against backsiphonage and backpressure. An integrated SentryPlus Alert® flood sensor detects excessive relief valve discharge, offering advanced monitoring capabilities when paired with an optional connection kit. This assembly is ASSE 1013, CSA B64.4, and NSF/ANSI 61-G approved, making it ideal for industrial, hospital, and irrigation systems requiring maximum contamination protection.
Help Me Connect
Help Me Connect
Connections
- This 2 inch backflow preventer assembly features NPT ANSI/ASME B1.20.1 threaded end connections for direct installation into your piping system.
- Ensure proper thread sealant is used for a watertight connection.
Flood Sensor Connectivity
- The integrated SentryPlus Alert® flood sensor requires an add-on connection kit (sold separately) to enable communication. These kits allow integration with Building Management Systems (BMS) via RS-485 Modbus, cellular communication, or the Nexa® platform through Wi-Fi to provide remote alerts.
Installation Clearance
- Maintain a minimum clearance of 12 inches from any fixed structure to allow for proper installation and maintenance.

Collapsible content
Additional Details
This 2 inch FEBCO Lead Free Reduced Pressure Zone Backflow Preventer Assembly is designed to prevent the reverse flow of high hazard (toxic) fluids from entering the potable water supply due to backsiphonage or backpressure. It is engineered for critical applications requiring maximum protection against contamination.
Construction and Components
- Features a robust lead free bronze body for durability and compliance.
- Includes two independently operating, spring-loaded check valves and a pressure differential relief valve for reliable performance.
- Equipped with threaded quarter turn ball valves for easy shutoff and maintenance.
- Four top-mounted test cocks are integrated for convenient testing.
Flood Detection and Monitoring
- Incorporates a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve.
- An add-on connection kit (sold separately) is required to activate the flood sensor for remote alerts via BMS (Building Management Systems) using RS-485 Modbus, cellular communication, or the Nexa® platform through Wi-Fi connectivity.
- Without an add-on connection kit, the sensor is a passive component with no communication capabilities.
Key Features
- Lead free construction complies with reduced lead content requirements.
- Modular relief valve and check valves simplify maintenance and repair.
- Quarter turn shutoff valves provide quick and reliable isolation.
Applications
- Ideal for water services to industrial plants, hospitals, morgues, mortuaries, and chemical plants.
- Suitable for use in irrigation systems, boiler feed lines, and other installations demanding high-level backflow protection.
Specifications
- Nominal Pipe Size: 2 inch
- End Connections: NPT ANSI/ASME B1.20.1
- Shutoff Valves: Quarter Turn Ball Valves
- Flood Sensor: SentryPlus Alert® Technology
Pressure & Temperature
- Max. Working Pressure: 175 psi (12.1 bar)
- Hydrostatic Test Pressure: 350 psi (24.1 bar)
- Temperature Range: 32°F to 140°F (0°C to 60°C)
Materials
- Valve Body: Lead Free* cast copper silicon alloy
- Elastomers: Silicone
- Springs: Stainless steel
Certificates & Approvals
- ANSI/AWWA Conformance: C511
- Approved by: Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California
- ASSE: 1013
- CSA: B64.4
- NSF: NSF/ANSI 61-G
FAQs
What is the primary purpose of this backflow preventer?
This backflow preventer is designed to prevent the reverse flow of high hazard (toxic) fluids from contaminating the potable water supply, protecting against both backsiphonage and backpressure events.
What materials are used in its construction?
The main valve body and caps are made from Lead Free* cast copper silicon alloy. The elastomers are silicone, and the springs are stainless steel, ensuring durability and compliance with lead-free standards.
Does this assembly include a flood detection feature?
Yes, it includes a flood sensor with SentryPlus Alert® technology to detect excessive water discharge from the relief valve. An add-on connection kit is required to activate the sensor for remote alerts.
What are the temperature and pressure limits for this device?
This assembly is rated for a maximum working pressure of 175 psi (12.1 bar) and can operate within a temperature range of 32°F to 140°F (0°C to 60°C).
How does this assembly connect to the piping system?
The assembly features NPT ANSI/ASME B1.20.1 end connections, allowing for secure threaded installation into your piping system.