2 ZW209 FIRE PROTECTION PRESSURE REDUCG VALVE, 400#, FNPT X FNPT
Item Number: 2-ZW209FPTHBrand - Wilkins
Couldn't load pickup availability
- Connection Type: 2 inch FNPT Threaded
- Body Style: Full Port Globe
- Maximum Pressure Rating: 400 PSI
- Pilot Spring Range: 15-120 PSI
- Corrosion Protection: Internal and external epoxy coating
- Pressure Regulation: Pilot-operated for stable downstream pressure
- Maintenance: Includes isolation valves and pressure gauges
- Certifications: NSF/ANSI/CAN 61 Lead Free compliant
Description
Description
Help Me Connect
Help Me Connect
The Zurn Wilkins Model ZW209 is a 2 inch FNPT (Female National Pipe Taper) threaded valve designed for direct connection to pipes with matching 2 inch Male NPT threads. This configuration allows for secure and straightforward installation in various system layouts. It is important to ensure that connecting pipes have a compatible 2 inch Male NPT thread for proper sealing and functionality.

Collapsible content
Additional Details
The Zurn Wilkins Model ZW209 Pilot Operated Pressure Reducing Valve is designed for many applications where the reduction of high inlet pressures to safe and stable outlet pressure is required. This valve ensures constant downstream pressure regardless of changing flow rates.
Features
- Pilot operated assembly reacts to downstream pressure changes, allowing the main valve to modulate and maintain a constant set pressure.
- The main valve will seal shut once the downstream pressure reaches the pilot setting, preventing potential downstream damage.
- Epoxy coating applied internally and externally provides superior corrosion protection.
- Comes standard with isolation valves and pressure gauges for quick and easy maintenance or repair.
- Pressure regulation is not dependent on flow rate, resulting in minimal pressure loss through the valve.
- Available with globe, reduced port globe, and angle bodies for versatile installations.
Operation
The Zurn Wilkins Model ZW209 utilizes a pressure reducing pilot valve installed on the discharge side of the control circuitry. This pilot is a direct acting, normally open, spring loaded, diaphragm actuated valve. The valve operates by accurately sizing the valve and fine-tuning the control circuit with the pilot spring. Inlet pressure is piped to the pilot's inlet port, and a sensing line from the pilot's discharge side controls the diaphragm. This modulating action ensures that downstream pressure remains stable within narrow limits, irrespective of varying flow rates or inlet pressures.
The closing speed control (optional) on this valve should always be open at least three (3) turns off its seat.
Caution: The recommended installation orientation for Automatic Control Valves (ACVs) is horizontal, with the valve cover up. 6 inch and larger valves should only be installed horizontally with the valve cover up, due to the difficulty of properly bleeding air out of the cover and performing maintenance on valves installed in the vertical orientation.
Specifications
- Model: ZW209
- End Connection: 2 inch FNPT Threaded
- Body Type: Full Port Globe Style
- Maximum Pressure Rating: 400 PSI
- Minimum Inlet Pressure: 10 PSI
- Temperature Rating: 33°F to 140°F (Water)
- Pilot Spring Range: 15-120 PSI
Materials
- Main Valve Body: Ductile Iron ASTM A536
- Main Valve Bonnet: Ductile Iron ASTM A536
- Disc Guide: Stainless Steel
- Seat: Stainless Steel
- Disc: Buna-N Rubber
- Diaphragm: Nylon Reinforced Buna-N
- Stem: Stainless Steel
- Spring: Stainless Steel
Standard Features Included
- Coating: Epoxy Coated, FDA Approved
- Pilot Assembly components include: "Wye" Type Strainer, Opening Speed Control (sizes 1 1/4" - 4"), Isolation Valves, Inlet and Outlet Pressure Gauges, ANSI Class 150 Flanges, Copper Tubing and Brass Fittings
Certificates & Approvals
- Standards Compliance: ANSI/AWWA C530
- Certification: NSF/ANSI/CAN 61 (0.25% MAX. WEIGHTED AVERAGE LEAD CONTENT)
- Certification: Lead Free