3/4 LF007M3-QT-FZ

Item Number: T063231
Skip to product information
1 of 1
Regular price $695.02
In Stock (10)
Estimated transit time: 2 to 5 Business Days Eligible for Express Shipping

Brand - Watts

  • Size: 3/4 inch
  • Weight: 5.05 lb
  • Connection Type: NPT
  • Body Material: Lead Free* Cast Copper Silicon Alloy
  • Maximum Operating Pressure: 175 PSI
  • Features: Freeze Sensor with SentryPlus Alert® compatibility
  • Design: Modular, compact for easy maintenance
  • Corrosion Resistance: ArmorTek coating on internal and external surfaces
  • Approvals: ASSE 1015, AWWA C510, IAPMO PS31, CSA B64.5, UPC

Description

The Watts 3/4 inch LF007M3-QT-FZ Lead Free Double Check Valve Backflow Preventer Assembly is designed to prevent polluted water from entering potable water supplies due to backsiphonage or backpressure. This assembly features a durable lead-free cast copper silicon alloy body, NPT end connections, and quarter-turn ball valve shutoffs. Its modular, compact design allows for easy maintenance with a single top-entry cover and replaceable seats. An integrated freeze sensor, compatible with SentryPlus Alert® technology and optional connection kits, provides alerts for freezing temperatures. Approved to ASSE 1015, AWWA C510, and CSA B64.5, it ensures reliable protection in non-health hazard continuous pressure applications.

Help Me Connect

This Watts LF007M3-QT-FZ double check valve backflow preventer features NPT end connections for easy installation into existing piping systems.

Compatibility

  • Designed for installation at cross-connections identified as non-health hazards.
  • Suitable for continuous pressure piping applications.
  • Can be installed in both horizontal and vertical "flow up" orientations.
  • The integral freeze sensor connects to an optional connection kit (sold separately) to enable communication with Wi-Fi networks, Building Management Systems (BMS), or Irrigation Management Systems (IMS).
View full details

Collapsible content

Additional Details

This 3/4 inch lead free double check valve backflow preventer assembly is designed to prevent the backflow of polluted water from entering into the potable water supply due to backsiphonage or backpressure in accordance with national plumbing codes and water authority requirements.

Its compact modular design facilitates easy maintenance with a single access cover for in-line repairs. It is ideal for protection in continuous pressure piping applications and at cross-connections identified as non-health hazards and for contaminants at the service line entrance.

Components

  • Lead Free* cast copper silicon alloy body construction
  • NPT end connections
  • Quarter turn ball valve shutoffs
  • Top mounted test cocks
  • Two in-line independent positive seating check modules
  • Captured springs
  • Replaceable check discs and seats

Freeze Sensor Features

  • Includes a freeze sensor for use with SentryPlus Alert® technology to signal facility personnel when temperature nears and reaches the freezing point.
  • Available freeze sensor connection kit to activate a monitoring system that triggers alerts for low and freezing temperatures.
  • Freeze alerts feature available with an add-on connection kit for Wi-Fi networks, building management systems (BMS), and irrigation management systems (IMS).

WARNING: The freeze sensor solely provides alerts about a possible freeze event and cannot prevent a freeze event from occurring. User action is required to prevent freeze conditions from causing product and/or property damage.

Specifications

  • Nominal Size: 3/4 inch
  • Connection Type: NPT
  • Body Material: Lead Free* cast copper silicon alloy
  • Coating: ArmorTek powder coating, applied to internal and external surfaces
  • Check Module: Captured spring and rubber seat disc
  • Access Cover Bolts: Stainless steel
  • Shutoff Type: Quarter Turn Ball Valves
  • Special Feature: Freeze Sensor (SentryPlus Alert® compatible)

Performance

  • Temperature Range: 33°F – 180°F (0.5°C – 82°C)
  • Maximum Working Pressure: 175 psi (12.1 bar)

Dimensions

  • Overall Length: 11 1/8 inches (282 mm)
  • Weight: 5.0 lbs (2.3 kg)

Certificates & Approvals

  • ASSE Standard 1015
  • AWWA Standard C510
  • IAPMO PS31
  • CSA B64.5
  • ASSE, AWWA, IAPMO, CSA, UPC
  • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California
  • UL Classified (without shutoff valves, 3/4" to 2")
  • Horizontal and vertical "flow up" approval on all sizes

FAQs

What is the primary purpose of the Watts LF007M3-QT-FZ backflow preventer?

Its primary purpose is to prevent the backflow of polluted water from entering the potable water supply due to backsiphonage or backpressure, in accordance with national plumbing codes.

What is the body material of this backflow preventer?

The body is constructed from Lead Free* cast copper silicon alloy, ensuring compliance with lead-free installation requirements.

How does the integrated freeze sensor work?

The freeze sensor, compatible with SentryPlus Alert® technology, monitors temperature and provides alerts to facility personnel if temperatures approach or reach freezing. An optional add-on connection kit is required to activate its monitoring system and Wi-Fi/BMS/IMS integration.

Is special tooling required for maintenance of this assembly?

No, this backflow preventer features a modular, compact design with a single top-entry cover, allowing for easy maintenance and in-line repairs without the need for special tools.

What is the maximum operating pressure and temperature range?

This assembly has a maximum working pressure of 175 psi (12.1 bar) and operates within a temperature range of 33°F to 180°F (0.5°C to 82°C).