3 5000SS-DOSY-FxG-GPM-FS

Item Number: F0694029
Skip to product information
1 of 1
Regular price $9,800.25
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Size: 3 inch
  • Weight: 226.0 lb
  • Body Material: Stainless Steel
  • Gate Valves: Domestic OSY Resilient Seated
  • Inlet Connection: Flanged
  • Outlet Connection: Grooved
  • Flood Sensor: SentryPlus Alert Technology
  • Bypass Meter: Gallons Per Minute (GPM)
  • Maximum Working Pressure: 175 PSI

Description

The Ames Fire & Waterworks 3 inch Series 5000SS Reduced Pressure Detector Backflow Preventer Assembly protects potable water supplies from hazardous cross-connections in non-potable fireline, irrigation, or industrial processing applications. This assembly features a lightweight stainless steel body, domestic OSY shutoff valves, a flanged inlet, and a grooved outlet. It includes a gallons per minute (GPM) meter for leak detection and a SentryPlus Alert flood sensor to detect continuous relief valve discharge. The flood sensor, when paired with an add-on kit, offers connectivity to BMS, cellular, or Wi-Fi networks for real-time alerts. Item number F0694029.

Help Me Connect

Connections

  • The inlet side features a 3 inch flanged connection for secure attachment to your system.
  • The outlet side is equipped with a 3 inch grooved connection, designed for easy installation with grooved piping systems.

Flood Sensor Connectivity

The integrated flood sensor requires an add-on sensor connection kit to activate its alert capabilities. This kit allows integration with Building Management Systems (BMS), cellular networks, or via the Nexa platform (Wi-Fi) and RS-485 Modbus using the Sensor Control Monitor.

View full details

Collapsible content

Additional Details

This 3 inch stainless steel reduced pressure detector backflow preventer assembly protects potable water supplies from hazardous cross-connections caused by backsiphonage or backpressure in non-potable service applications such as irrigation, fireline, or industrial processing.


It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes.

Flood Detection System

  • Includes a flood sensor with SentryPlus Alert technology to detect continuous discharge from the relief valve.
  • An add-on sensor connection kit is required to activate the flood sensor and enable communication.
  • Connection kit options include BMS, cellular communication, and the Sensor Control Monitor for integration with BAS via RS‑485 Modbus or the Nexa platform through Wi-Fi.
  • The sensor relays a signal to facility personnel for corrective action, thus limiting flooding and costly damage.
  • Watts® is not responsible for the failure of alerts due to connectivity issues, power outages, or improper installation.

Design and Construction

  • Stainless steel body provides long-term corrosion resistance, maximum strength, and reduces installation/shipping costs due to its lightweight nature.
  • Features domestic outside stem and yoke (OSY) resilient seated gate valves.
  • Short end-to-end dimensions make retrofit installations easier.
  • Bottom-mounted relief valve reduces clearance requirements.
  • Thermoplastic cam-check valves provide maximum flow at low pressure drop.
  • No special tools are required for servicing.
  • Compact construction allows for smaller enclosures.
  • Stainless steel relief valve uses a balanced rolling diaphragm, eliminating sliding seals and lowering maintenance costs.
  • A gallons per minute (GPM) meter is included on the bypass line to detect underground leaks and unauthorized water use.

Specifications

  • Product Type: Reduced Pressure Detector Backflow Preventer Assembly
  • Nominal Size: 3 inch
  • Body Material: 300 Series Stainless Steel
  • Main Valve Body Material: 300 Series Stainless Steel
  • Check Assembly Material: Noryl®
  • Gate Valves: Domestic OSY Resilient Seated Gate Valves
  • Inlet Connection: Flanged
  • Outlet Connection: Grooved
  • Bypass Line Meter: Gallons Per Minute (GPM)
  • Flood Sensor: SentryPlus Alert Technology Enabled

Performance

  • Maximum Working Pressure: 175 PSI (12.1 bar)
  • Temperature Range: 33°F – 110°F (0.5°C – 43°C)

Certificates & Approvals

  • AWWA C511-92
  • ASSE 1047
  • CSA B64.5
  • UL Classified
  • FM Approved

FAQs

What is the primary use of this backflow preventer?

This backflow preventer is designed to protect potable water supplies from contamination due to backsiphonage or backpressure in non-potable applications like firelines, irrigation, and industrial processing.

Can this product be used for drinking water systems?

No, it is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Always consult local water authorities and codes.

How does the flood sensor work?

The integrated SentryPlus Alert flood sensor detects excessive water discharges from the relief valve. When paired with an add-on connection kit, it can relay alerts via BMS, cellular communication, or Wi-Fi to facility personnel.

What types of connections does this backflow preventer have?

This 3 inch assembly features a flanged connection on the inlet side and a grooved connection on the outlet side, providing versatile installation options.

What material is the main body made from?

The main valve body and all internal metal parts are constructed from 300 Series stainless steel, offering excellent corrosion resistance and maximum strength.