3 5000SS-OSY-GPM-FS

Item Number: F0690542
Skip to product information
1 of 1
Regular price $9,800.25
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Size: 3 inch
  • Weight: 220.0 lb
  • Maximum Working Pressure: 175 psi
  • Temperature Range: 33°F – 110°F
  • Main Valve Body Material: 300 Series Stainless Steel
  • Includes Flood Sensor with SentryPlus Alert® Technology
  • Comes with Gallon Per Minute (GPM) Meter
  • UL Classified and FM Approved
  • Short End-to-End Dimensions for Easy Retrofit

Description

This Ames Series 5000SS 3 inch Reduced Pressure Detector Backflow Preventer Assembly is designed for non-potable service applications like firelines and industrial processing. It features a durable 300 Series stainless steel body and UL/FM approved OSY shutoff valves. The assembly prevents backsiphonage and backpressure of hazardous materials into potable water supplies. Key features include a flood sensor with SentryPlus Alert® technology for discharge detection and a gallon per minute meter for leak monitoring. It operates up to 175 PSI and is built for easy retrofit with short end-to-end dimensions. Item F0690542.

Help Me Connect

Flood Sensor Connectivity

  • The integrated flood sensor requires an add-on connection kit to activate and communicate alerts.
  • Connection kit options allow compatibility with Building Management Systems (BMS), cellular networks, or integration with Building Automation Systems (BAS) via RS-485 Modbus or the Nexa® platform through Wi-Fi.
View full details

Collapsible content

Additional Details

This 3 inch Ames Series 5000SS Reduced Pressure Detector Backflow Preventer Assembly is designed to protect drinking water supplies by preventing backsiphonage and backpressure of hazardous materials into the potable water supply. It is ideal for non-potable service applications such as irrigation, fireline, or industrial processing, especially in health hazard applications requiring protection at cross-connections.


WARNING: It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building, and plumbing codes.

Features & Benefits

  • Stainless steel construction provides long-term corrosion resistance and maximum strength.
  • Lightweight stainless steel body reduces installation and shipping costs.
  • Short end-to-end dimensions make retrofit easy.
  • Bottom-mounted relief valve reduces clearance requirements.
  • Cam-check valves provide maximum flow at low pressure drop.
  • No special tools required for servicing.
  • Compact construction allows for smaller enclosures.
  • Stainless steel relief valve with a balanced rolling diaphragm eliminates sliding seals and lowers maintenance costs.
  • Includes a gallon per minute meter to detect underground leaks and unauthorized water use.
  • Features a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve.
  • The flood sensor provides alerts for potential flooding events when paired with an add-on sensor connection kit.
  • Compatible with BMS and cellular network communication, or integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi when using a connection kit.

Construction & Materials

  • Main Valve Body: 300 Series stainless steel
  • Internal Metal Parts: 300 Series stainless steel
  • Check Assembly: Noryl®
  • Test Cocks: Bronze body ball valve
  • Shutoff Valves: UL and FM Approved outside stem and yoke resilient seated gate valves

Specifications

  • Size: 3 inch
  • Bypass Line: 3/4 inch with GPM meter
  • Model: 5000SS

Performance

  • Maximum Working Pressure: 175 psi (12.1 bar)
  • Temperature Range: 33°F – 110°F (0.5°C – 43°C)

Materials

  • Main Valve Body: 300 Series stainless steel
  • Internal Metal Parts: 300 Series stainless steel
  • Check Assembly: Noryl®
  • Shutoff Valves: UL and FM Approved Outside Stem and Yoke Resilient Seated Gate Valves
  • Test Cocks: Bronze

Certificates & Approvals

  • AWWA C511-92
  • ASSE 1047
  • CSA B64.5
  • UL Classified
  • FM Approved

FAQs

What is the primary purpose of this backflow preventer?

This backflow preventer assembly is designed to protect drinking water supplies by preventing the reverse flow of hazardous materials from non-potable sources into the potable water supply, typically in fireline, irrigation, or industrial applications.

What materials are used in the construction of the 5000SS assembly?

The main valve body and all internal metal parts are constructed from 300 Series stainless steel for corrosion resistance. The check assembly uses Noryl®, and the test cocks are made of bronze.

How does the flood sensor feature work?

The assembly includes a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. To activate communication and alerts, an add-on sensor connection kit is required, which enables integration with BMS, cellular networks, or BAS platforms.

What is the maximum operating pressure and temperature range?

This 3 inch backflow preventer is rated for a maximum working pressure of 175 psi (12.1 bar). It operates effectively within a temperature range of 33°F to 110°F (0.5°C to 43°C).

Is this backflow preventer approved by industry standards?

Yes, this model is UL Classified and FM Approved. It also meets AWWA C511-92, ASSE 1047, and CSA B64.5 standards, ensuring reliability and compliance for various applications.