3 709DCDA-DOSY-GPM

Item Number: 0389316
Skip to product information
1 of 1
Regular price $15,169.10
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Watts

  • Size: 3 inch
  • Weight: 327.0 lb
  • Body Material: Fused epoxy coated cast iron
  • Coating: ArmorTek® (3-part advanced epoxy system)
  • Corrosion Resistance: Microbial-induced (MIC) and electrochemical
  • Shutoff Valves: OSY resilient seated gate valves
  • Bypass Meter: 5/8" x 3/4" bronze GPM meter
  • Maximum Working Pressure: 175 psi
  • Application: Non-health hazard cross-connections

Description

The Watts 3 inch 709DCDA Double Check Detector Assembly prevents backflow of non-potable water and fire protection substances into potable water lines. Featuring a durable fused epoxy coated cast iron body with patented ArmorTek® coating, it offers superior resistance to microbial-induced corrosion. This assembly includes UL Classified and FM Approved OSY shutoff valves and a gallons per minute bypass meter for leak detection. Ideal for non-health hazard cross-connections, it provides reliable protection with easy maintenance.

Help Me Connect

Installation Guidelines

  • This 3 inch double check detector assembly is designed for horizontal installation only.
  • It is mandatory for installation on fire protection systems when connected to a potable water supply.
  • The unit is designed to protect potable water lines from the reverse flow of non-potable substances such as glycerin wetting agents or stagnant water.
  • Consult local authorities for specific installation requirements and degree of hazard determination.
View full details

Collapsible content

Additional Details

This 3 inch double check detector backflow preventer assembly is designed to prevent the reverse flow of fire protection substances and water of non-potable quality into the potable water supply.

It is ideal for protection at cross-connections identified as non-health hazards, such as on fire protection systems and from other contaminants found at the service line entrance.

Construction & Design

  • Features a fused epoxy coated cast iron body.
  • Equipped with domestic outside stem and yoke (OSY) resilient seated gate valves.
  • Includes captured spring check valves.
  • Incorporates a gallons per minute (GPM) metered bypass to detect underground leaks and unauthorized water use.
  • Modular check design concept facilitates complete maintenance and assembly access.
  • No special tools required for servicing.

Corrosion Protection

  • Utilizes ArmorTek® coating technology, a patented three-part advanced epoxy system engineered to reduce microbial-induced corrosion (MIC) and protect exposed metal substrate.
  • Coating applied to both internal and external surfaces.

Specifications

  • Product Type: Double Check Detector Assembly Backflow Preventer
  • Size: 3 inch
  • Body Material: Cast iron
  • Coating: ArmorTek® powder coating (applied to internal and external surfaces)
  • Seat Material: Bronze
  • Disc Holder Material: Bronze
  • Trim Material: Stainless steel
  • Check Valve Disc Material: Rubber
  • Test Cocks Material: Bronze
  • Shutoff Valves: UL Classified and FM Approved outside stem and yoke (OSY) resilient seated gate valves
  • Bypass Meter: 5/8" x 3/4" bronze meter (Gallons per minute - GPM)
  • Maximum Working Pressure: 175 psi (12.1 bar)
  • Temperature Range: 33°F - 110°F (0.5°C – 43°C) continuous, 140°F (60°C) intermittent

Certificates & Approvals

  • AWWA Standard C510
  • UL Classified
  • FM Approved
  • ASSE 1048
  • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California
  • CSA B64.4

FAQs

What is the primary function of the Watts 709DCDA Double Check Detector Assembly?

Its primary function is to prevent the reverse flow of fire protection system substances and non-potable water into the potable water supply, protecting against both backsiphonage and backpressure.

What is ArmorTek® coating and what are its benefits?

ArmorTek® is a patented three-part advanced epoxy system applied to the internal and external surfaces of the cast iron components. It is engineered to reduce microbial-induced corrosion (MIC) and protect exposed metal substrates, enhancing the longevity of the assembly.

What type of applications is this backflow preventer suitable for?

This assembly is ideal for cross-connections identified as non-health hazards, such as those found on fire protection systems and at service line entrances where contaminants could be present.

Does this 3 inch model have any specific installation requirements regarding orientation?

Yes, the 3 inch model of the 709DCDA Double Check Detector Assembly is approved and designed for horizontal installation only.

What is the purpose of the bypass meter included with this assembly?

The 5/8" x 3/4" bronze gallons per minute (GPM) bypass meter is designed to detect underground leaks that could lead to unaccountable water loss and to identify unauthorized water use.