Brand - Ames
Couldn't load pickup availability
- Nominal Size: 3 inch
- Weight: 180.0 lb
- Lead Free Reduced Pressure Zone (RPZ) Backflow Preventer
- Prevents backsiphonage and backpressure
- Integrated flood sensor with SentryPlus Alert® technology
- 304 (Schedule 40) stainless steel housing and sleeve
- OS&Y resilient seated gate valves: Flanged Inlet x Grooved Outlet
- Maximum Working Pressure: 175 psi
- Approved by ASSE 1013, CSA B64.4, UL, FM, NSF 61-G
Description
Description
This Colt 3 inch Lead Free Reduced Pressure Zone (RPZ) backflow preventer assembly prevents the reverse flow of fire protection substances and non-potable water into the potable water supply. Designed for continuous pressure piping and health hazard cross-connections, it features a 304 stainless steel body, OS&Y resilient seated gate valves with a flanged inlet, and a grooved outlet. An integrated flood sensor with SentryPlus Alert® technology detects excessive relief valve discharges, requiring an add-on connection kit for active alerts. It is rated for 175 psi maximum working pressure and 33-140°F, and holds approvals including ASSE 1013, CSA B64.4, UL, FM, and NSF 61-G.
Help Me Connect
Help Me Connect
Installation & Connections
- Designed for horizontal installation; ensure alignment with the flow arrow for proper operation.
- Features a flanged inlet connection for secure attachment to the upstream piping system.
- Equipped with a grooved outlet connection for easy integration with downstream grooved piping.
- Utilizes groove couplings to facilitate installation and pipe alignment.
- When installing a drain line, use a 400/500 air gap to prevent potential backflow into the drain system.

Collapsible content
Additional Details
This Colt™ 3 inch lead free reduced pressure zone backflow preventer assembly is designed to prevent the reverse flow of fire protection substances and water of non-potable quality into the potable water supply due to backsiphonage and backpressure.
It is ideal for protection in continuous pressure piping applications and at cross-connections identified as health hazards. It is approved for horizontal installation when installed in accordance with the direction of the flow arrow.
Construction & Components
- Features a stainless steel body with a quick access sleeve
- Includes two independent Link Check modules with torsion spring checks for ease of serviceability
- Equipped with OS&Y resilient seated gate valves with flanged inlet and grooved outlet
- Contains required test cocks and a bottom mounted pressure relief valve
- Utilizes groove couplings for easy installation and pipe alignment
- Features drip tight shutoff valves
- Wetted surfaces contain less than 0.25% lead by weight
Flood Detection & Alerts
- Includes a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve
- When paired with an add-on connection kit, the sensor is activated to relay alerts for potential flooding events
- Connection kit options include BMS, cellular communication, and the Sensor Control Monitor
- The Sensor Control Monitor enables integration with BAS via RS‑485 Modbus or the Nexa® platform through Wi-Fi
- An add-on connection kit is required to activate the flood sensor. Without the connection kit, the flood sensor is a passive component and will not communicate with any other device.
Specifications
- Product Type: Reduced Pressure Zone (RPZ) Backflow Preventer
- Nominal Size: 3 inch
- Model: C400-OSY-FxG-FS
- Brand: Colt (Ames Fire & Waterworks, A Watts Brand)
- Housing & Sleeve Material: Type 304 (Schedule 40) stainless steel
- Elastomer Materials: EPDM, silicone, Buna 'N'
- Link Check Material: Noryl®, stainless steel
- Check Disc Material: Reversible silicone or EPDM
- Test Cock Material: Lead Free* bronze body
- Pins & Fastener Material: 300 Series stainless steel
- Spring Material: Stainless steel
- Valve Type: OS&Y resilient seated gate valves (UL Classified and FM Approved)
- Inlet Connection: Flanged
- Outlet Connection: Grooved
- Flood Sensor: Integrated with SentryPlus Alert® technology
- Configuration: Horizontal
- Temperature Range: 33°F - 140°F (0.5°C - 60°C)
- Maximum Working Pressure: 175 psi (12.1 bar)
- Wetted Surface Lead Content: Less than 0.25%
Dimensions (Approximate)
- Overall Length (A): 31 3/4 inch (806 mm)
- Height (C OSY): 18 7/8 inch (479 mm)
- Depth (D): 10 1/4 inch (260 mm)
- Weight (OSY): 161 lb (73 kg)
Certificates & Approvals
- Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California (FCCCHR-USC)
- AWWA C511-97
- ASSE 1013
- CSA B64.4
- UL Classified (for OSY model)
- FM Approved (for OSY model)
- NSF Certified to NSF/ANSI 61-G
FAQs
What is the primary purpose of the Colt 3 inch C400-OSY-FxG-FS backflow preventer?
This assembly is designed to prevent the reverse flow of fire protection substances and non-potable water into the potable water supply. It protects against contamination caused by backsiphonage and backpressure in continuous pressure piping applications.
What does "Lead Free" mean for this product?
The term "Lead Free" indicates that the wetted surfaces of this backflow preventer, which come into contact with consumable water, contain less than 0.25% lead by weight. This complies with Lead Free installation requirements.
How does the integrated flood sensor function?
The flood sensor with SentryPlus Alert® technology detects excessive water discharges from the relief valve. To activate alerts for potential flooding events, an add-on connection kit (available separately, e.g., BMS, cellular, or Sensor Control Monitor) is required.
What type of connections does this backflow preventer utilize?
This model features OS&Y resilient seated gate valves with a flanged inlet connection and a grooved outlet connection. It is designed for easy installation and pipe alignment using groove couplings.
What are the key certifications and approvals for this Colt C400 series assembly?
This backflow preventer is approved by ASSE 1013, AWWA C511-97, CSA B64.4, UL Classified, FM Approved, and NSF Certified to NSF/ANSI 61-G. It also has approval from the Foundation for Cross-Connection Control and Hydraulic Research at USC.