- 3 inch nominal pipe size
- Weight: 300.0 lb
- Lead Free* construction
- Type 304 Stainless Steel Housing & Sleeve
- OS&Y Resilient Seated Gate Valves
- Integrated Flood Sensor with SentryPlus Alert
- Maximum Working Pressure: 175 psi
- Approved for Horizontal N-Pattern Installation
- Groove couplings for easy installation
Description
Description
Help Me Connect
Help Me Connect
Installation Orientation
- This assembly is approved for horizontal N pattern installation. Ensure that installation adheres to the direction of the flow arrow and all local codes and requirements.
Flood Sensor Activation
- The integrated flood sensor requires an add-on connection kit to become active and communicate alerts.
- Without a connection kit, the sensor remains a passive component and will not provide flood notifications.
- Compatible connection kit options include BMS, cellular communication, or the Sensor Control Monitor for integration with BAS via RS-485 Modbus or the Nexa platform through Wi-Fi.
Drain Line Recommendation
- When installing a drain line on the Series C400 backflow preventer, use a 400/500 air gap.

Collapsible content
Additional Details
The Colt 3 inch C400N Reduced Pressure Zone backflow preventer assembly is engineered to protect potable water systems from contamination by preventing reverse flow of fire protection substances and non-potable water due to backsiphonage or backpressure.
This assembly is ideal for health hazard applications and continuous pressure piping, featuring a stainless steel body, torsion spring check modules, and resilient seated OS&Y gate valves.
Flood Detection & Alerting
- Includes a flood sensor with SentryPlus Alert technology to detect excessive water discharges from the relief valve.
- When paired with an add-on connection kit, the sensor activates to relay alerts for potential flooding events via multichannel alerts (call, email, text).
- Connection kit options include BMS, cellular communication, or the Sensor Control Monitor for integration with BAS via RS-485 Modbus or the Nexa platform through Wi-Fi.
Design & Construction
- Lead Free* construction ensures wetted surfaces contain less than 0.25% lead by weight.
- Features an extremely compact design, up to 70% lighter than traditional designs.
- Constructed with a Type 304 (Schedule 40) stainless steel housing and sleeve.
- Torsion spring check modules provide unmatched ease of serviceability and lowest pressure loss.
- Equipped with resilient seated OS&Y (Outside Stem and Yoke) gate valves.
- Groove couplings allow for easy installation and integral pipeline adjustment.
- Replaceable check disc rubber for maintenance.
NOTICE: An add-on connection kit is required to activate the flood sensor. Without this kit, the flood sensor is a passive component and will not communicate with other devices.
Specifications
General
- Product Type: Reduced Pressure Zone Backflow Preventer Assembly
- Series: C400N
- Nominal Size: 3 inch
- Connection Type: Grooved
- Shutoff Valve Type: OS&Y Resilient Seated Gate Valves
- Flood Sensor: Included (SentryPlus Alert Technology)
Materials
- Housing & Sleeve: Type 304 (Schedule 40) Stainless Steel
- Elastomers: EPDM, Silicone, Buna 'N'
- Link Checks: Noryl®, Stainless Steel
- Check Discs: Reversible Silicone or EPDM
- Test Cocks: Lead Free* Bronze Body
- Pins & Fasteners: 300 Series Stainless Steel
- Springs: Stainless Steel
Performance
- Maximum Working Pressure: 175 psi (12.1 bar)
- Temperature Range: 33°F - 140°F (0.5°C - 60°C)
Dimensions & Weight (Approximate)
- Overall Length (A): 31 3/4 inch (806 mm)
- Face-to-Face (C-OSY): 18 7/8 inch (479 mm)
- Pipe Center to Relief Valve Bottom (D): 10 1/4 inch (260 mm)
- Overall Height (H): 22 1/4 inch (565 mm)
- Overall Width (P): 23 inch (584 mm)
- Approximate Weight: 161 lb (73 kg)
Certificates & Approvals
- Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
- AWWA C511-97
- ASSE 1013
- CSA B64.4
- UL Listed
- FM Approved
- NSF/ANSI 61-G
FAQs
What is the primary function of the Colt 3 inch C400N Reduced Pressure Zone Backflow Preventer?
Is this backflow preventer considered "Lead Free"?
How does the integrated flood sensor work, and what is required to activate it?
What are the approved installation orientations for this C400N backflow preventer?
What are the maximum operating pressure and temperature range for this unit?
Related Products
-
-
-
Item Number: 7019628
Ames® 2 1/2" –10" 400/500 Lead Free Air Gap Drain Fitting w/ Splash Guard
Regular price $253.88Limited Stock