- Size: 3 inch
- Weight: 60.0 lb
- Housing Material: 304 Stainless Steel
- Maximum Working Pressure: 175 psi
- Temperature Range: 33°F - 140°F
- Equipped with GPM bypass meter
- Integral shutoff valves with prewired supervisory switches
- SentryPlus Alert® Flood Sensor technology
- AWWA C511-07 Compliant, UL Listed
Description
Description
The 3 inch Ames Deringer 50 reduced pressure detector backflow preventer assembly (RPDA-II) with a 304 stainless steel housing prevents potable water contamination from backpressure and backsiphonage. Primarily used in fire sprinkler systems to monitor water use, it features integral butterfly shutoff valves, dual-action checks for low and high flow, a GPM bypass meter, and prewired supervisory switches. The unit also includes a SentryPlus Alert flood sensor and operates from 10-175 psi across a 33-140°F temperature range. It is AWWA C511-07, ANSI/NSF/CAN 61, and UL 372 Lead Free certified.
Help Me Connect
Help Me Connect
Connections
- This assembly features IPS grooved ends designed for direct connection to steel pipe in accordance with AWWA C606 standards.
- For alternative connection types, flanged adapters compatible with ANSI B16.1 Class 125 are available separately.
- The integral shutoff valves simplify installation and provide isolation for maintenance.

Collapsible content
Additional Details
This 3 inch Ames Deringer™ 50 reduced pressure detector Type II backflow preventer assembly is designed to prevent hazardous contaminants and non-health hazard pollutants from entering the potable water supply system caused by backpressure and/or backsiphonage conditions. It is primarily required on fire sprinkler systems to monitor unauthorized water use.
Key Features
- Features integral Eccentric-Seal™ butterfly shutoff valves for a shorter lay length and lightweight construction, suitable for indoor or outdoor applications.
- Equipped with a 100% stainless steel housing for durability.
- Includes a Patented Dual-action™ second check module that operates as a poppet style check under low flow and a swing style check under high flow for optimal performance.
- The assembly contains a balanced chamber relief valve with no sliding seals and a poppet action first check for more reliable relief valve closure.
- Comes with lead free bronze bypass components and a GPM (gallons per minute) bypass meter for monitoring unauthorized water usage.
- Features prewired supervisory switches and integrated tamper switches within a weatherproof actuator housing, alongside tamper-resistant test cocks.
- Incorporates a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. Add-on sensor connection kits are available for BMS and cellular communications.
- Designed for continuous pressure service.
- Equipped with IPS grooved ends; flanged adapters are available separately.
Specifications
- Size: 3 inch
- Type: Reduced Pressure Detector Assembly (RPDA-II)
- Housing Material: 304 Stainless Steel
- Valve Cover Material: 304 Stainless Steel
- SOV Disks Material: EPDM/304SS
- SOV Shafts Material: 304 Stainless Steel
- Bypass Spring Material: 302 Stainless Steel
- RV Spring Material: 302 Stainless Steel
- SOV Bearings Material: PTFE Fluoropolymer/Bronze
- Non-wetted Bolts Material: Grade 8 Zinc Plated
- Check Disks Material: Silicone (NSF)
- Wetted Fasteners Material: 18-8 Stainless Steel
- Bypass Components Material: Lead Free Bronze
- RV Housing Material: 304 Stainless Steel
- Check Springs Material: 17-7 Stainless Steel
- Check Pins Material: 17-7/18-8 Stainless Steel
- Check Seats Material: Noryl® Polymer (NSF)
- O-rings Material: Buna-N (NSF)
- Bypass Internals Material: ABS Polymer (NSF)
- RV Hose Material: Braided Stainless Steel Wire
Performance
- Temperature Range: 33°F - 140°F
- Maximum Working Pressure: 175 psi
Connections
- End Connections: IPS Groove for Steel Pipe (AWWA C606)
- Bypass Meter: GPM (Gallons Per Minute)
Dimensions (3 inch Model 50)
- Overall Height (H): 16.1 in (409 mm)
- Length (L): 18.7 in (475 mm)
- Width (W): 11.0 in (279 mm)
- Weight: 49 lb (22 kg)
Certificates & Approvals
- AWWA C511-07 Compliant
- ANSI/NSF/CAN 61 UL Certified Health Effects
- UL Certified to ANSI/NSF/CAN 372 LEAD FREE
- FM APPROVED
- ASSE 1047-2021 APPROVED
- USC APPROVED
- CULUS Classified Water Quality [MH64212] ANSI/NSF/CAN 61 ANSI/NSF/CAN 372 5NS5
FAQs
What is the primary purpose of the 3 inch Ames Deringer 50 backflow preventer?
Its primary purpose is to prevent hazardous contaminants and non-health hazard pollutants from entering the potable water supply system due to backpressure and/or backsiphonage conditions. It is also commonly used in fire sprinkler systems to monitor unauthorized water usage.
What materials are used for the main housing of this backflow preventer?
The main valve housing and cover are constructed entirely of 304 stainless steel, ensuring durability and corrosion resistance.
What is the maximum operating pressure and temperature range for this assembly?
This backflow preventer has a maximum working pressure of 175 psi and an operating temperature range of 33°F to 140°F.
Does this Deringer 50 model include a bypass meter?
Yes, it includes a lead-free bronze bypass assembly with a GPM (gallons per minute) meter to monitor water flow through the bypass, which is useful for detecting unauthorized water use.
What is the function of the SentryPlus Alert® flood sensor?
The SentryPlus Alert® flood sensor detects excessive water discharges from the relief valve, providing an early warning system for potential flooding. It can be connected to external communication kits for remote alerts.