3 LF009-OSY-FS

Item Number: F122651
Skip to product information
1 of 1
Regular price $9,883.28
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Watts

  • Size: 3 inch
  • Body Material: Cast Iron with ArmorTek® Coating
  • Valve Type: UL/FM OSY Resilient Seated Gate
  • Lead Free Construction: Yes
  • Maximum Supply Pressure: 175 psi
  • Flood Sensor: SentryPlus Alert® Technology
  • Connections: NPT Inlet and Outlet
  • Maintenance: Single Access Cover, Replaceable Seats

Description

The 3 inch Watts Series LF009 Reduced Pressure Zone Backflow Preventer Assembly, model F122651, protects potable water supplies from backflow contamination due to backsiphonage or backpressure. This lead-free unit features a robust cast iron body with ArmorTek® advanced epoxy coating for superior corrosion resistance, UL and FM Approved OSY resilient seated gate valves, and NPT connections. It incorporates a SentryPlus Alert® flood sensor to detect relief valve discharge, with activation via an add-on connection kit for BMS, cellular, or Wi-Fi monitoring. Designed for health hazard cross-connections and continuous pressure applications, it offers easy maintenance with a single access cover and replaceable internal components.

Help Me Connect

NPT Connections

This 3 inch backflow preventer assembly features NPT inlet and outlet connections for standard threaded pipe installations.

Flood Sensor Connectivity

  • The integrated flood sensor with SentryPlus Alert® technology detects excessive water discharges from the relief valve.
  • To activate full flood monitoring and relay alerts, an add-on sensor connection kit is required.
  • Connection kit options include compatibility with BMS (Building Management Systems) and cellular communication.
  • The Sensor Control Monitor connection kit enables integration with BAS (Building Automation Systems) via RS-485 Modbus or the Nexa® platform through Wi-Fi connectivity.
View full details

Collapsible content

Additional Details

This 3 inch Watts Series LF009 Reduced Pressure Zone Backflow Preventer Assembly is designed to protect potable water supplies from backflow caused by backsiphonage or backpressure. It is ideal for preventing health hazard cross-connections and contamination in continuous pressure piping applications.

Construction & Materials

  • Features a durable cast iron body construction coated with ArmorTek®, a patented three-part advanced epoxy system that resists microbial-induced corrosion (MIC) and protects exposed metal substrate.
  • Designed with Lead Free* construction, ensuring the wetted surface contains less than 0.25% lead content.
  • Equipped with UL and FM Approved Outside Stem and Yoke (OSY) resilient seated gate valves for reliable shutoff.
  • Includes two in-line independent check valves, captured springs, and replaceable check seats, along with an internal relief valve for reduced installation clearances.
  • Features NPT inlet and outlet connections.

Key Features

  • Compact, space-saving design facilitates installation in various settings.
  • Single access cover and modular check construction ensure ease of maintenance and economical repair with replaceable seats.
  • Top entry to all internals allows for immediate accessibility.
  • Captured springs provide safer maintenance.
  • Large body passages ensure low pressure drop.
  • No special tools are required for servicing.

Flood Sensor Technology

  • Integrated flood sensor with SentryPlus Alert® technology detects continuous discharge from the relief valve, preventing potential flooding.
  • When paired with an add-on sensor connection kit, the sensor activates to relay alerts for potential flooding events via BMS, cellular communication, or the Sensor Control Monitor for BAS/Nexa® Wi-Fi integration.

Specifications

General

  • Product Type: Reduced Pressure Zone Backflow Preventer Assembly
  • Model Series: LF009
  • Size: 3 inch
  • Valve Type: UL and FM Approved OSY Resilient Seated Gate Valves
  • Body Material: Cast Iron
  • Coating: ArmorTek® Advanced Epoxy (internal and external surfaces)
  • Lead Free: Yes (wetted surface contains less than 0.25% lead)
  • Connections: NPT Inlet and Outlet
  • Flood Sensor: Integrated SentryPlus Alert® Technology

Performance (2 1/2" - 3")

  • Maximum Supply Pressure: 175 psi (12.1 bar)
  • Continuous Water Temperature: 110°F (43°C)
  • Intermittent Water Temperature: 140°F (60°C)

Certificates & Approvals

  • USC
  • ASSE Std. 1013
  • AWWA C511
  • CSA B64.4
  • IAPMO File No. 1563
  • UL Classified
  • FM Approved
  • NSF Certified to NSF/ANSI/CAN 61-G
  • Approved by Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California

FAQs

What is the primary purpose of the Watts LF009 Reduced Pressure Zone Backflow Preventer?

The primary purpose of this assembly is to protect potable water supplies from contamination caused by backsiphonage or backpressure from non-potable sources, ensuring water safety in accordance with plumbing codes.

What material is the body of this 3-inch backflow preventer made from, and how is it protected?

The body of this 3-inch backflow preventer is constructed from cast iron. It is protected with ArmorTek®, a patented three-part advanced epoxy coating system, which resists microbial-induced corrosion (MIC) and safeguards exposed metal surfaces.

Does this LF009 assembly include a flood sensor, and how does it function?

Yes, this LF009 assembly includes an integrated flood sensor with SentryPlus Alert® technology. It detects continuous water discharge from the relief valve. To activate full flood monitoring and alerts, an add-on sensor connection kit is required.

What type of shutoff valves are included with this specific LF009 model?

This LF009 model (OSY-FS) is equipped with UL and FM Approved Outside Stem and Yoke (OSY) resilient seated gate valves, designed for reliable operation and easy visual indication of valve position.

What are the maximum pressure and temperature ratings for the 3-inch LF009?

For the 3-inch LF009, the maximum supply pressure is 175 psi (12.1 bar). It can handle continuous water temperatures up to 110°F (43°C) and intermittent temperatures up to 140°F (60°C).