3 LF709-QT-FDA-IOT
Item Number: 88003409Brand - Watts
Couldn't load pickup availability
- Size: 3 inch
- Body Material: Fused Epoxy Coated Cast Iron
- Coating: ArmorTek® corrosion-resistant epoxy system
- Lead Free: Yes (less than 0.25% lead content)
- Maximum Working Pressure: 175 psi
- Temperature Range: 33°F – 110°F (0.5°C – 43°C)
- Integrated pressure sensors for monitoring
- Approved for vertical flow up installation
Description
Description
Help Me Connect
Help Me Connect
Connections & Compatibility
This Watts LF709 Double Check Valve Backflow Preventer is designed for installation in potable water systems to prevent the reverse flow of polluted water from non-health hazard cross-connections. The assembly features standard flanged connections for integration into your piping system. For advanced monitoring, its integrated pressure sensors require an add-on monitoring connection kit (sold separately) to transmit data to Building Management Systems (BMS) or Building Automation Systems (BAS) via a wired serial (RS-485) interface. Consult local jurisdictional authorities for specific installation requirements.

Collapsible content
Additional Details
This 3 inch Watts LF709 Lead Free Double Check Valve Backflow Preventer Assembly is designed to prevent the reverse flow of polluted water from entering into the potable water supply system. It is ideal for continuous pressure piping applications and non-health hazard cross-connections.
Construction & Design
- Features a fused epoxy coated cast iron body for durability.
- Utilizes a modular check design concept to facilitate complete maintenance, allowing access to captured spring assemblies without special tools.
- Equipped with FDA epoxy coated quarter-turn ball valves and replaceable stainless steel seats.
- Approved for vertical flow up installation.
Corrosion Protection
- Incorporates ArmorTek® coating technology, a patented three-part advanced epoxy system, to resist both microbial-induced corrosion (MIC) and exposed metal substrate corrosion.
- Constructed with Lead Free* materials, ensuring the wetted surface contacted by consumable water contains less than 0.25% lead by weight.
Smart & Connected Monitoring
- Comes standard with Smart and Connected technology, including integrated sensors at test cocks No. 2, No. 3, and No. 4 to measure pressure fluctuations.
- An add-on monitoring connection kit (sold separately) is required to activate these sensors and transmit data over a wired serial (RS-485) interface to a Building Management or Building Automation System (BMS/BAS). This enables monitoring of assembly performance and the water supply system.
Specifications
General
- Product Type: Double Check Valve Backflow Preventer
- Series: LF709
- Size: 3 inch
- Connection Type: Flanged
- Body Material: Fused Epoxy Coated Cast Iron
- Coating: ArmorTek® Patented 3-Part Advanced Epoxy System
- Valve Type: FDA Epoxy Coated Quarter-Turn Ball Valves
- Seat Material: Stainless Steel (replaceable)
- Lead Free: Yes (wetted surface less than 0.25% lead)
Performance
- Maximum Working Pressure: 175 psi (12.1 bar)
- Temperature Range: 33°F – 110°F (0.5°C – 43°C) continuous
- Flow Characteristics: Maximum flow at low pressure drop
Monitoring & Technology
- Sensors: Integrated pressure sensors at Test Cocks No. 2, 3, and 4
- Monitoring Compatibility: Requires add-on connection kit for BMS/BAS integration (wired serial RS-485)
- Installation Orientation: Approved for vertical flow up
Certificates & Approvals
- ASSE: No. 1015
- AWWA: C510-92
- CSA: B64.5
- UL Classified: File No. EX3185
- Foundation for Cross-Connection Control and Hydraulic Research: Approved
- IAPMO: ME PA-10
- FM Approved: For Cross-Connection Control, 8th Edition
- State Codes: Complies with reduced lead content requirements