3 LF957RPDA-OSY-GPM-FS

Item Number: F122725
Skip to product information
1 of 1
Regular price $7,775.88
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Watts

  • Size: 3 inch
  • Weight: 213.0 lb
  • Construction: Lead Free*
  • Housing Material: 304 Stainless Steel
  • Shutoff Valves: UL Classified and FM Approved OSY Gate
  • Maximum Working Pressure: 175 PSI
  • Temperature Range: 33°F to 110°F
  • Features: Integrated flood sensor with SentryPlus Alert® technology
  • Features: Gallon per minute meter for leak detection
  • Design: Extremely compact and 70% lighter than traditional models

Description

The Watts 3 inch Lead Free Reduced Pressure Detector Backflow Preventer Assembly, model LF957RPDA-OSY-GPM-FS, safeguards potable water systems from contamination due to backpressure or backsiphonage, ideal for health hazard and fire protection applications. It features durable 304 stainless steel housing, UL/FM Approved OSY shutoff valves, and a compact design. An integrated SentryPlus Alert® flood sensor detects relief valve discharge, while a gallon per minute meter monitors for leaks or unauthorized water use. This assembly ensures compliance with national plumbing codes, operating up to 175 PSI within a 33°F to 110°F temperature range. Item number F122725.

Help Me Connect

Flood Sensor Activation

  • To activate the integrated flood sensor with SentryPlus Alert® technology, an add-on sensor connection kit (sold separately) is required. Without this kit, the sensor remains a passive component with no communication capabilities.
  • Connection kit options allow for compatibility with Building Management Systems (BMS), cellular communication, or the Sensor Control Monitor which enables integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.

Pipeline Connections

  • The assembly utilizes groove fittings, which allow for integral pipeline adjustment, simplifying installation and alignment with existing piping.
View full details

Collapsible content

Additional Details

This 3 inch lead free reduced pressure detector backflow preventer assembly protects the potable water system from contamination due to backpressure or backsiphonage, in accordance with national plumbing codes. It is used in health hazard applications to monitor unauthorized water use from fire protection systems and to prevent reverse flow of liquids.

Primary Use

  • Provides protection for potable water systems against contamination from backpressure or backsiphonage
  • Suitable for health hazard applications
  • Monitors unauthorized water use from fire protection systems

Construction & Design

  • Features Lead Free* construction to comply with Lead Free* installation requirements
  • Extremely compact design, approximately 70% lighter than traditional models
  • Constructed with 304 (Schedule 40) stainless steel housing and sleeve
  • Groove fittings allow for integral pipeline adjustment
  • Equipped with two independent torsion spring check modules
  • Includes a differential pressure relief valve located between and below the check modules
  • Features UL Classified and FM Approved outside stem and yoke (OSY) resilient seated gate valves
  • Furnished with a gallon per minute meter for bypass assembly to detect leakage or theft of water
  • Replaceable check disc rubber for unmatched ease of serviceability

Integrated Flood Detection & Monitoring

  • Includes a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve
  • The sensor relays a signal to trigger notification to facility personnel, limiting flooding and costly damage
  • Flood alert feature is activated with an add-on sensor connection kit (sold separately)
  • Compatible with BMS and cellular network communication when connected
  • Integrates with the Sensor Control Monitor to deliver maintenance alerts to BAS via RS-485 Modbus or the Nexa® platform by Wi-Fi connectivity

Use of the flood sensor does not replace the need to comply with all required instructions, codes, and regulations related to installation, operation, and maintenance of this product, including the need to provide proper drainage in the event of a discharge. An add-on connection kit is required to activate the flood sensor. Without the connection kit, the sensor is a passive component that has no communication with any other device.

Specifications

  • Size: 3 inch
  • Type: Reduced Pressure Detector Assembly
  • Construction: Lead Free*
  • Housing & Sleeve Material: 304 (Schedule 40) Stainless Steel
  • Elastomers: EPDM, Silicone, Buna 'N'
  • Torsion Spring Checks: Noryl®, Stainless Steel
  • Check Discs: Reversible Silicone or EPDM
  • Test Cocks: Lead Free* Bronze Body
  • Pins & Fasteners: 300 Series Stainless Steel
  • Springs: Stainless Steel
  • Shutoff Valves: UL Classified and FM Approved OSY Resilient Seated Gate Valves
  • Relief Valve: Bottom Mounted Cast Stainless Steel
  • Bypass: Gallon Per Minute Meter
  • Flood Sensor Technology: SentryPlus Alert®

Performance

  • Maximum Working Pressure: 175 PSI (12.1 bar)
  • Temperature Range: 33°F - 110°F (0.5°C - 43°C)

Certificates & Approvals

  • ASSE 1047
  • CSA B64.4
  • UL Classified
  • FM Approved
  • NSF Certified to NSF/ANSI 372
  • AWWA C511-97
  • Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC) - excluding 6", 8", and 10" N- and Z-pattern installations

FAQs

What is the primary function of this 3 inch backflow preventer?

This backflow preventer assembly is designed to protect potable water systems from contamination caused by backpressure or backsiphonage, especially in health hazard applications and fire protection systems. It also monitors for unauthorized water use.

What does 'Lead Free*' construction mean for this product?

The 'Lead Free*' construction means that the wetted surface of this product, which comes into contact with consumable water, contains less than 0.25% of lead by weight. This complies with Lead Free installation requirements and national plumbing codes.

How does the integrated flood sensor with SentryPlus Alert® technology work?

The flood sensor detects excessive water discharges from the relief valve. When paired with an add-on connection kit (sold separately), it activates to relay alerts to facility personnel or integrates with building management systems via various communication options, helping to prevent costly flooding.

What type of shutoff valves are included with this backflow preventer?

This assembly is equipped with UL Classified and FM Approved outside stem and yoke (OSY) resilient seated gate valves. These provide reliable shutoff capability and are a common requirement for fire protection systems.

What is the purpose of the gallon per minute meter on this assembly?

The gallon per minute (GPM) meter is part of the bypass assembly and is used to detect leakage from the fire sprinkler system or unauthorized water use. This helps in identifying potential issues early and conserving water.