3 LFC300-BFG-GPM
Item Number: 0124584Brand - Ames
Couldn't load pickup availability
- Nominal Size: 3 inch
- Weight: 71.0 lb
- Housing Material: 304 (Schedule 40) stainless steel
- Maximum Operating Pressure: 175 psi
- Temperature Range: 33°F - 110°F
- Lead Free: Yes (wetted surfaces contain less than 0.25% lead)
- Valve Type: Grooved gear operated butterfly with tamper switch
- Includes: Gallons/minute bypass meter
- Certifications: AWWA C510-97, ASSE 1048, CSA B64.5, FM, NSF
Description
Description
Help Me Connect
Help Me Connect
This 3 inch Colt™ Lead Free Double Check Detector Backflow Preventer Assembly features groove end connections on the main line for integration into compatible piping systems. The bypass assembly is produced with ASME/ANSI flanged end connections.
It is designed for use in fire sprinkler systems and other non-health hazard cross-connections to protect potable water supplies from backsiphonage and backpressure.
The assembly can be installed in horizontal, vertical up, or "N" pattern horizontal configurations.

Collapsible content
Additional Details
This Colt™ 3 inch lead free double check detector backflow preventer assembly is designed to prevent the reverse flow of objectionable, non-toxic pollutants into the potable water supply. It is primarily used on fire line sprinkler systems when monitoring unauthorized water use is necessary, and for general non-health hazard applications where backsiphonage or backpressure may occur.
The assembly features a compact, modular design with a single access sleeve for simplified maintenance and is suitable for both horizontal and vertical installations.
Key Features
- Extremely compact design and 70% lighter than traditional models for easier installation in smaller vaults and enclosures.
- Constructed with a 304 (Schedule 40) stainless steel housing and sleeve for durability.
- Features grooved gear operated butterfly valves with tamper switch and groove fittings for integral pipeline adjustment.
- Includes patented Tri-Link checks for lowest pressure loss and unmatched ease of serviceability.
- Equipped with a bypass assembly that includes a meter to register in gallons or cubic measurement, detecting underground leaks and unauthorized water use.
- Reversible elastomer check discs provide drip tight closure against reverse flow.
- Suitable for horizontal, vertical, or "N" pattern installations.
- The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight, meeting Lead Free* requirements.
The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. Inquire with governing authorities for local installation requirements.
Specifications
- Product Type: Double Check Detector Backflow Preventer Assembly
- Brand: Colt
- Model: LFC300BFG
- Nominal Size: 3 inch
- Lead Free: Yes (wetted surface contains less than 0.25% lead by weight)
- Installation Orientation: Horizontal, Vertical up, "N" pattern horizontal
Materials
- Housing & Sleeve: 304 (Schedule 40) stainless steel
- Elastomers: EPDM, Silicone, Buna 'N'
- Tri-Link Checks: Noryl®, Stainless steel
- Check Discs: Reversible Silicone or EPDM
- Test Cocks: Lead Free* bronze body
- Pins & Fasteners: 300 Series stainless steel
- Springs: Stainless steel
Performance
- Maximum Working Pressure: 175 psi (12.06 bar)
- Temperature Range: 33°F - 110°F (5°C - 43°C)
Dimensions & Weight (3 inch LFC300BFG)
- Weight: 68 lb (31 kg)
- Dimension A: 28 1/4 inch (718 mm)
- Dimension C: 8 5/16 inch (211 mm)
- Dimension D: 3 11/16 inch (94 mm)
- Dimension G: 30 11/16 inch (779 mm)
- Dimension H: 22 1/4 inch (565 mm)
- Dimension J: 15 7/16 inch (392 mm)
- Dimension P: 13 1/2 inch (343 mm)
Certificates & Approvals
- Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
- AWWA C510-97
- ASSE 1048
- CSA B64.5
- cULus Classified
- FM Approved
- NSF Certified to NSF/ANSI 372