3 LFC500Z-BFG-G-FS
Item Number: F0124677
1
/
of
1
Regular price
$11,707.49
Special Order
When Will it Ship:
Contact for Lead Time
Estimated transit time: 2 to 5 Business Days
Brand - Ames
Couldn't load pickup availability
- Size: 3 inch
- Weight: 109.0 lb
- Lead Free* construction for potable water systems
- Housing & Sleeve Material: Type 304 (Schedule 40) Stainless Steel
- Approved for horizontal Z pattern installation
- Flood sensor with SentryPlus Alert® technology
- Grooved gear operated butterfly valves with tamper switch
- Maximum Operating Pressure: 175 psi
- Integrated gallon per minute meter for leak detection
Description
Description
The Colt 3 inch Lead Free Reduced Pressure Detector Backflow Preventer Assembly provides critical protection for potable water systems. It prevents contamination from backsiphonage and backpressure in fire protection applications. Featuring a compact, horizontal Z-pattern design and durable Type 304 stainless steel construction, this unit is significantly lighter than traditional models. It includes grooved butterfly shutoff valves with tamper switches, a metered bypass for leak detection, and a SentryPlus Alert flood sensor to detect excessive water discharge. This assembly is lead-free and approved by multiple industry standards.

Collapsible content
Additional Details
This Colt™ 3 inch lead free reduced pressure detector backflow preventer assembly is designed to prevent the reverse flow of fire protection substances and water of non-potable quality from being pumped or siphoned into the potable water supply due to backsiphonage and/or backpressure. This compact, modular assembly is approved for horizontal Z pattern installation and is used to monitor unauthorized water use from the fire protection system.
Construction & Design
- Features an extremely compact design, making it 70% lighter than traditional designs
- The entire valve body and closure sleeve are manufactured from Type 304 (Schedule 40) stainless steel pipe with groove end connections
- Includes two independent Link Check modules with torsion spring check valves and reversible elastomer discs for drip-tight closure
- Comes with grooved gear operated butterfly valves featuring a tamper switch for reliable shutoff
- A corrosive resistant bottom-mounted pressure relief valve is included
- Equipped with bronze body nickel plated test cocks for easy maintenance and testing
- A metered bypass assembly, furnished with a gallon per minute meter, detects underground leaks and unauthorized water use
Advanced Monitoring
- Integrates a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve
- When paired with an add-on connection kit (sold separately), the sensor activates to relay alerts for potential flooding events to notify personnel
- Connection kit options include BMS, cellular communication, and the Sensor Control Monitor which enables integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi
Specifications
- Product Type: Reduced Pressure Detector Backflow Preventer Assembly
- Brand: Colt
- SKU: F0124677
- Size: 3 inch
- Model Series: LFC500
- Configuration: Z pattern horizontal
- Housing & Sleeve Material: Type 304 (Schedule 40) Stainless Steel
- Elastomers: EPDM, Silicone, Buna-N
- Link Checks Material: Noryl®, Stainless Steel
- Check Discs Material: Reversible Silicone or EPDM
- Test Cocks Material: Lead Free* Bronze Body, Nickel Plated
- Pins & Fasteners Material: 300 Series Stainless Steel
- Springs Material: Stainless Steel
- Shutoff Valves: Grooved Gear Operated Butterfly Valves with Tamper Switch (BFG)
- Flood Sensor: Yes, with SentryPlus Alert® Technology (requires add-on connection kit for activation)
- Bypass Meter: Gallon per Minute Meter
- Temperature Range: 33°F - 110°F (0.5°C – 43°C)
- Maximum Working Pressure: 175 psi (12.1 bar)
Certificates & Approvals
- Approved by: Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
- Certification: AWWA C511-97
- Certification: ASSE 1047
- Certification: CSA B64.4
- Certification: UL Classified
- Certification: FM Approved
- Certification: NSF Certified to NSF/ANSI 372
FAQs
What is the primary function of this Colt backflow preventer?
This backflow preventer is designed to protect potable water systems from contamination by preventing the reverse flow of non-potable fire protection substances and water due to backsiphonage and backpressure.
What does 'Lead Free' mean for this product?
The 'Lead Free' designation indicates that the wetted surface of this product, which comes into contact with consumable water, contains less than 0.25% of lead by weight, complying with national plumbing codes.
How does the flood sensor feature work?
The integrated flood sensor with SentryPlus Alert® technology detects excessive water discharges from the relief valve. To activate alerts for potential flooding, an add-on connection kit (purchased separately) is required to enable communication with monitoring systems.
What type of shutoff valves are included with this assembly?
This assembly is furnished with UL Classified and FM Approved grooved gear operated butterfly valves that include an integrated tamper switch for enhanced security and monitoring.
What kind of installation configuration is supported?
This particular model, the LFC500Z, is specifically approved for horizontal Z pattern installation, offering a compact and modular design for various setups.