3 M300-OSY-GPM

Item Number: 0191039
Skip to product information
1 of 1
Regular price $9,722.25
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Size: 3 inch
  • Weight: 236.0 lb
  • Housing Material: 304 (Schedule 40) Stainless Steel
  • Check Valve Type: Patented Tri-Link Check
  • Shutoff Valves: UL/FM Flanged OSY Gate Valves
  • Maximum Working Pressure: 175 PSI
  • Temperature Range: 33°F - 110°F
  • Meter: Gallons/Minute
  • Installation: Horizontal or Vertical

Description

The Ames Maxim M300 Double Check Detector Backflow Preventer Assembly, 3 inch, with OSY Shutoffs and Tri-Link Checks, is engineered to safeguard drinking water supplies from non-health hazard cross-connections. Featuring a compact 304 stainless steel housing, this assembly is 70% lighter than traditional designs, allowing for smaller installations. Its patented Tri-Link Checks ensure low pressure loss and unmatched serviceability, while the integrated gallon per minute meter monitors for unauthorized water use. Approved by ASSE, AWWA, cULus, and FM, it offers reliable protection for fire sprinkler systems and industrial processing.

Help Me Connect

This Ames Maxim™ M300 Double Check Detector Assembly is designed for installation in horizontal or vertical orientations, following the direction of flow indicated on the assembly. It features flanged OSY gate valves for shutoff, facilitating connection to compatible piping systems. The grooved fittings allow for integral pipeline adjustment, ensuring a secure and adaptable installation for fire line sprinkler systems and other non-potable applications.

View full details

Collapsible content

Additional Details

This Maxim™ 3 inch double check detector backflow preventer assembly is designed to protect drinking water supplies from dangerous cross-connections, in accordance with national plumbing codes and water authority requirements. It is primarily used on fire line sprinkler systems and other non-health hazard, non-potable service applications where monitoring for unauthorized water use is necessary.

Features

  • Extremely Compact Design: 70% lighter than traditional designs, allowing for smaller vaults and enclosures.
  • 304 (Schedule 40) Stainless Steel housing and sleeve provide long-term corrosion protection and maximum strength.
  • Patented Tri-Link Check valve assembly offers the lowest pressure loss and drip-tight closure.
  • Unmatched Ease of Serviceability: Tri-Link Checks are removable and serviceable without special tools.
  • Groove Fittings allow integral pipeline adjustment.
  • Furnished with a gallon per minute meter to detect underground leaks and unauthorized water use.
  • Available for horizontal, vertical, or N pattern installations.
  • Check discs are replaceable with rubber.

Connections

  • Features UL/FM flanged outside stem and yoke resilient seated gate valves (OSY) for shutoff.

It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installation, consult local water authority, building, and plumbing codes.

Specifications

General

  • Product Type: Double Check Detector Backflow Preventer Assembly
  • Brand: Ames Fire & Waterworks
  • Series: Maxim™ M300, M300N
  • Size: 3 inch
  • Housing & Sleeve Material: 304 (Schedule 40) Stainless Steel
  • Elastomers: EPDM, Silicone, Buna 'N'
  • Tri-Link Checks: Noryl®, Stainless Steel
  • Check Discs: Reversible Silicone or EPDM
  • Test Cocks: Lead Free* Bronze Body
  • Pins & Fasteners: 300 Series Stainless Steel
  • Springs: Stainless Steel
  • Valve Type: UL/FM Flanged OSY (Outside Stem and Yoke) Resilient Seated Gate Valves
  • Meter Type: Gallons/Minute Meter

Performance

  • Maximum Working Pressure: 175 PSI (12.06 bar)
  • Temperature Range: 33°F - 110°F (5°C – 43°C)

Certificates & Approvals

  • Approved by: Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
  • AWWA C510-97
  • ASSE 1048
  • CSA B64.5
  • cULus Classified
  • FM Approved

FAQs

What is the primary use of this backflow preventer assembly?

This Maxim M300 Double Check Detector Backflow Preventer Assembly is designed to protect drinking water from non-health hazard cross-connections, primarily for fire line sprinkler systems and other non-potable service applications where water use monitoring is required.

Can this assembly be installed in any orientation?

Yes, this compact modular design is approved for horizontal or vertical installation, in accordance with the direction of the flow arrow on the assembly.

What type of shutoff valves are included with this model?

This assembly is furnished with UL/FM flanged outside stem and yoke (OSY) resilient seated gate valves, which allow for visual confirmation of valve position.

What is the maximum operating pressure and temperature?

The maximum working pressure for this assembly is 175 PSI (12.06 bar), and it can operate within a temperature range of 33°F to 110°F (5°C to 43°C).

What material is the main housing constructed from?

The housing and sleeve are constructed from 304 (Schedule 40) stainless steel, providing long-term corrosion protection and maximum strength for durability.