Brand - Ames

  • Size: 4 inch
  • Weight: 243.0 lb
  • Type: Reduced Pressure Detector Assembly
  • Housing Material: 304 Stainless Steel
  • Shutoff Valves: OSY Resilient Seated Gate Valves
  • Max Working Pressure: 175 PSI
  • Flood Sensor: SentryPlus Alert® technology
  • Connections: Grooved
  • Approvals: UL Classified, FM Approved, AWWA C511-97

Description

The Colt C500 4 inch Reduced Pressure Detector Backflow Preventer Assembly provides critical protection for potable water supplies against health-hazard cross-connections. This robust unit prevents backsiphonage and backpressure in applications like fire sprinkler systems and industrial processing. It features a durable 304 stainless steel housing, OSY resilient seated gate valves, and grooved connections for easy installation. An integrated SentryPlus Alert® flood sensor detects excessive discharges, offering proactive monitoring when paired with an add-on connection kit. Rated for 175 PSI, it is UL Classified, FM Approved, and AWWA C511-97 compliant.

Help Me Connect

Flood Sensor Connectivity

This backflow preventer features a SentryPlus Alert® flood sensor to detect excessive water discharges from the relief valve. To activate flood monitoring and relay alerts, an add-on connection kit is required. Without this kit, the sensor remains a passive component and will not communicate with external devices.

Connection Kit Options

  • BMS (Building Management System) integration via RS-485 Modbus.
  • Cellular Communication for remote alerts.
  • Sensor Control Monitor for Wi-Fi connectivity via the Nexa® platform.

A retrofit sensor connection kit is also available for existing installations.

View full details

Collapsible content

Additional Details

This Colt™ 4 inch reduced pressure detector backflow preventer assembly is designed to prevent the reverse flow of non-potable water and fire protection substances into the potable water supply. It is ideal for protecting drinking water from dangerous cross-connections caused by backsiphonage or backpressure, such as in fire sprinkler systems and industrial processing lines.

WARNING: It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Consult your local water authority, building, and plumbing codes before installing.

The C500 series includes a flood sensor on the relief valve to detect excessive water discharges. When activated by an add-on connection kit, the sensor relays alerts for potential flooding events.

Construction & Operation

  • Features a 304 (Schedule 40) stainless steel housing and sleeve with groove end connections.
  • Consists of two independent Link Check modules and a differential pressure relief valve.
  • Includes two outside stem and yoke (OSY) resilient seated gate valves that provide drip-tight shutoff.
  • Equipped with a gallon per minute meter for detecting leakage or unauthorized water use.
  • Bottom-mounted cast stainless steel relief valve.
  • Integrated supervisory switch on each gate valve (OSY model).

Key Features

  • Extremely compact design, approximately 70% lighter than traditional designs.
  • Patented link check for lowest pressure loss and unmatched ease of serviceability.
  • Replaceable check disc rubber for simple maintenance.
  • Flood sensor with SentryPlus Alert® technology for discharge detection.

Specifications

  • Size: 4 inch
  • Brand: Colt (Ames Fire & Waterworks)
  • Model: C500
  • Type: Reduced Pressure Detector Assembly
  • Shutoff Valves: Outside Stem and Yoke (OSY) resilient seated gate valves
  • Flood Sensor: SentryPlus Alert® technology
  • Housing & Sleeve Material: 304 (Schedule 40) stainless steel
  • Elastomers: EPDM, Silicone, Buna 'N'
  • Link Checks Material: Noryl®, Stainless Steel
  • Check Disc Material: Reversible Silicone or EPDM
  • Test Cock Material: Lead Free* Bronze Body
  • Pins & Fasteners Material: 300 Series Stainless Steel
  • Springs Material: Stainless Steel
  • Relief Valve Material: Bottom-mounted Cast Stainless Steel
  • Connections: Grooved

Performance Data

  • Temperature Range: 33°F - 140°F (0.5°C ~ 60°C)
  • Maximum Working Pressure: 175 PSI (12.1 bar)

Certificates & Approvals

  • Approved by the Foundation for Cross-Connection Control and Hydraulic Research (FCCCHR-USC)
  • AWWA C511-97
  • ASSE 1047
  • CSA B64.4
  • UL Classified
  • FM Approved

FAQs

What is the primary function of this backflow preventer?

This Colt C500 Reduced Pressure Detector Assembly is designed to protect potable water supplies from contamination due to backsiphonage and backpressure, commonly found in fire sprinkler systems, irrigation, or industrial processing lines.

What material is the housing made from?

The housing and sleeve of this backflow preventer are constructed from durable 304 (Schedule 40) stainless steel, offering excellent corrosion resistance and longevity.

How does the integrated flood sensor work?

The backflow preventer includes a SentryPlus Alert® flood sensor on the relief valve to detect excessive water discharges. When activated with an add-on connection kit, it can relay alerts for potential flooding events.

What type of shutoff valves are included?

This assembly is equipped with outside stem and yoke (OSY) resilient seated gate valves. These valves provide drip-tight shutoff and include an option for an integrated supervisory switch.

What is the maximum operating pressure and temperature?

This 4-inch C500 assembly has a maximum working pressure of 175 PSI (12.1 bar) and operates within a temperature range of 33°F to 140°F (0.5°C to 60°C).