4 C500N-BFG-C-FS

Item Number: F0191462
Skip to product information
1 of 1
Regular price $12,377.04
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • 4 inch N-pattern horizontal backflow preventer
  • Weight: 100.0 lb
  • 304 stainless steel body and quick access sleeve
  • Grooved gear-operated butterfly shutoff valves with tamper switch
  • Integrated flood sensor with SentryPlus Alert® technology
  • Metered bypass detects leaks and unauthorized water use
  • Maximum operating pressure: 175 PSI
  • Lead Free* bronze body test cocks
  • AWWA C511-97, ASSE 1047, UL Classified, FM Approved

Description

The 4 inch Ames Fire & Waterworks C500N Reduced Pressure Detector Backflow Preventer Assembly with grooved butterfly shutoffs provides critical protection for potable water supplies against contamination from non-potable sources in fire lines, irrigation, and industrial processing. Featuring a durable 304 stainless steel body and an N-pattern horizontal configuration, this assembly includes a SentryPlus Alert flood sensor to detect excessive relief valve discharge. Its metered bypass also identifies leaks and unauthorized water use, ensuring system integrity and compliance. Item number F0191462.

Help Me Connect

Connections

  • This assembly utilizes grooved couplings for easy installation and pipe alignment.
  • It is equipped with grooved gear-operated butterfly valves with tamper switches.
  • The flood sensor feature can be extended with an add-on sensor connection kit for integrated monitoring via BMS, cellular communication, or the Sensor Control Monitor (compatible with BAS via RS-485 Modbus or Nexa® platform through Wi-Fi).
View full details

Collapsible content

Additional Details

This 4 inch Ames Fire & Waterworks C500N Reduced Pressure Detector Backflow Preventer Assembly is engineered to provide superior protection for drinking water supplies against contamination from dangerous cross-connections. It is ideal for health-hazard non-potable service applications such as irrigation, fire lines, or industrial processing systems. This model features a compact, modular N-pattern horizontal design with grooved gear-operated butterfly shutoff valves and a flood sensor.

WARNING

It is illegal to use this product in a plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes.

Key Features

  • Provides protection from backpressure and backsiphonage contamination.
  • Extremely compact design, making it 70% lighter than traditional models.
  • Constructed with a 304 (Schedule 40) stainless steel housing and sleeve for durability.
  • Features a patented link check for the lowest pressure loss and unmatched ease of serviceability.
  • Includes grooved gear-operated butterfly shutoff valves with tamper switches for secure operation and monitoring.
  • Equipped with a bottom-mounted cast stainless steel relief valve.
  • A metered bypass is included to detect leakage or unauthorized water use from the fire sprinkler system, furnished with a cubic feet per minute meter.
  • Integrated flood sensor with SentryPlus Alert® technology detects excessive water discharges from the relief valve.
  • The flood sensor can relay a signal to trigger a multichannel alert (call, email, text) to notify personnel about potential flooding, requiring an add-on sensor connection kit for activation.

Specifications

  • Series: C500
  • Size: 4 inch
  • Configuration: N-Pattern Horizontal
  • Housing & Sleeve Material: 304 (Schedule 40) Stainless Steel
  • Elastomers: EPDM, Silicone, Buna 'N'
  • Link Check Material: Noryl®, Stainless Steel
  • Check Disc Material: Reversible Silicone or EPDM
  • Test Cock Material: Lead Free* Bronze Body, Nickel Plated
  • Pins & Fastener Material: 300 Series Stainless Steel
  • Spring Material: Stainless Steel
  • Shutoff Valves: Grooved Gear Operated Butterfly with Tamper Switch
  • Flood Sensor: Integrated with SentryPlus Alert® Technology
  • Bypass Meter: Cubic Feet per Minute (CFM) Meter
  • Maximum Working Pressure: 175 psi (12.1 bar)
  • Temperature Range: 33°F - 140°F (0.5°C - 60°C)

Certificates & Approvals

  • UL Classified
  • FM Approved
  • AWWA C511-97
  • ASSE 1047
  • CSA B64.4
  • FCCCHR-USC (Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California)

FAQs

What is the primary purpose of this backflow preventer assembly?

This assembly is designed to protect potable (drinking) water supplies from dangerous cross-connections, preventing contamination from non-potable sources in health-hazard applications like fire lines, irrigation, and industrial processing.

What does the integrated flood sensor do?

The integrated flood sensor with SentryPlus Alert® technology detects excessive water discharges from the relief valve. When paired with an add-on connection kit, it can relay signals to trigger multichannel alerts for potential flooding events.

What material is the body of this backflow preventer made from?

The entire valve body and closure sleeve are constructed from durable 304 (Schedule 40) stainless steel, offering excellent corrosion resistance and longevity.

What type of shutoff valves are included with this model?

This model comes with grooved gear-operated butterfly valves, which include tamper switches for secure operation and monitoring of the valve's status.

Can this product be used in a plumbing system for human consumption?

No, it is illegal to use this product in a plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. It is designed to protect potable water supplies from contamination, not for direct potable water use.