Brand - Ames

  • Size: 4 inch
  • Weight: 266.0 lb
  • Housing Material: 304 (Schedule 40) Stainless Steel
  • Installation Pattern: Horizontal Z Pattern
  • Flood Sensor: Yes, with SentryPlus Alert® Technology
  • Shutoff Valves: OSY Resilient Seated Gate Valves
  • Maximum Working Pressure: 175 PSI
  • Connection: Groove Fittings
  • Features: Metered bypass for leak detection

Description

The Colt™ 4 inch Reduced Pressure Detector Backflow Preventer Assembly with OSY valves prevents the reverse flow of non-potable water and fire protection substances into the potable supply. Featuring a durable 304 stainless steel body, this compact unit is approved for horizontal Z pattern installation. It includes a SentryPlus Alert® flood sensor to detect excessive relief valve discharge, which activates with an add-on connection kit. A cubic feet per minute meter monitors for leaks and unauthorized water use. This assembly is designed for ease of serviceability and low pressure loss, approved by ASSE 1047, CSA B64.4, UL, and FM. Item number F0191332.

Help Me Connect

Connections and Compatibility

This 4 inch reduced pressure detector backflow preventer assembly is designed for easy installation into a pipeline system thanks to its groove couplings which allow for integral pipeline adjustment. It is approved for horizontal Z pattern installation. The integrated flood sensor with SentryPlus Alert® technology requires an add-on connection kit to be fully activated and capable of relaying alerts for potential flooding events. Connection kit options include those for Building Management Systems (BMS), cellular communication, and the Sensor Control Monitor, which integrates with Building Automation Systems (BAS) via RS-485 Modbus or the Nexa® platform through Wi-Fi.

View full details

Collapsible content

Additional Details

The Colt™ 4 inch reduced pressure detector backflow preventer assembly is designed to prevent the reverse flow of fire protection substances and non-potable water into the potable water supply, protecting against both backsiphonage and backpressure.

This compact, modular assembly features a 304 (Schedule 40) stainless steel body with a quick access sleeve and is approved for horizontal Z pattern installation. It is equipped with outside stem and yoke (OSY) resilient seated gate valves and a corrosive resistant bottom mounted pressure relief valve. A cubic feet per minute meter is furnished to detect underground leaks and unauthorized water use.

The assembly includes a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. When paired with an add-on connection kit, the sensor is activated to relay alerts for potential flooding events.

A WARNING: It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes.

Features

  • Extremely compact design
  • 70% lighter than traditional designs
  • 304 (Schedule 40) stainless steel housing and sleeve
  • Groove fittings for integral pipeline adjustment
  • Patented link check for lowest pressure loss
  • Unmatched ease of serviceability
  • Replaceable check disc rubber
  • Available with grooved butterfly valve shutoffs
  • Bottom-mounted cast stainless steel relief valve
  • Metered bypass to detect leakage or theft of water from the fire sprinkler system
  • Sensor on the relief valve for flood detection
  • Flood alert feature activated by add-on sensor connection kit
  • Includes an integrated supervisory switch as an option on each gate valve of the OS&Y model

Specifications

  • Product Type: Reduced Pressure Detector Backflow Preventer Assembly
  • Size: 4 inch
  • Installation Pattern: Horizontal Z pattern
  • Housing & Sleeve Material: 304 (Schedule 40) Stainless Steel
  • Elastomers: EPDM, Silicone, Buna 'N'
  • Link Checks Material: Noryl®, Stainless Steel
  • Check Discs Material: Reversible Silicone or EPDM
  • Test Cocks Material: Lead-Free Bronze Body
  • Fasteners Material: 300 Series Stainless Steel
  • Valves: Outside Stem and Yoke (OSY) Resilient Seated Gate Valves
  • Relief Valve: Bottom Mounted Cast Stainless Steel
  • Bypass Meter: Cubic Feet per Minute Meter
  • Flood Sensor: Yes, with SentryPlus Alert® technology
  • Maximum Working Pressure: 175 PSI
  • Temperature Range: 33°F - 140°F (0.6°C - 60°C)

Certificates & Approvals

  • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR - USC)
  • AWWA C511-97
  • ASSE 1047
  • CSA B64.4
  • UL Classified
  • FM Approved

FAQs

What is the primary purpose of this backflow preventer?

Its primary purpose is to prevent the reverse flow of non-potable water and fire protection substances from entering the potable (drinking) water supply due to backsiphonage or backpressure.

How is the flood sensor activated?

The integrated flood sensor with SentryPlus Alert® technology is activated by pairing it with an add-on connection kit, which enables it to relay alerts for potential flooding events.

What material is the housing made from?

The entire valve body and closure sleeve are manufactured from 304 (Schedule 40) stainless steel, offering robust durability.

What type of installation pattern is this assembly approved for?

This backflow preventer assembly is approved for horizontal Z pattern installation.

What type of shutoff valves are included?

This assembly is furnished with outside stem and yoke (OSY) resilient seated gate valves.