4 C500Z-OSY-G-FS

Item Number: F0191338
Skip to product information
1 of 1
Regular price $10,924.38
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Size: 4 inch
  • Weight: 266.0 lb
  • Model: C500Z-OSY-G-FS
  • Housing Material: 304 Stainless Steel
  • Configuration: Z Pattern Horizontal
  • Shutoff Valves: OSY Resilient Seated Gate Valves
  • Flood Sensor: SentryPlus Alert® Technology
  • Pressure Rating: 175 PSI Max
  • Bypass Meter: Gallon per minute

Description

The Colt 4 inch C500Z-OSY-G-FS Reduced Pressure Detector Backflow Preventer Assembly is designed for horizontal Z pattern installations, preventing dangerous cross-connections in non-potable fire protection, irrigation, or industrial systems. It features a compact 304 stainless steel body with OSY gate valves, an integral gallon per minute meter for leak detection, and a SentryPlus Alert® flood sensor to detect relief valve discharges. The flood sensor, when paired with an add-on connection kit, can relay alerts via BMS, cellular, or the Nexa® platform. This assembly is approved by AWWA, ASSE, CSA, UL, and FM for reliable performance.

Help Me Connect

Connections

  • The assembly features groove couplings for easy installation and pipeline alignment.
  • For flood sensor activation, an add-on connection kit is required. Available kit options support BMS, cellular communication, and the Sensor Control Monitor for integration with Building Automation Systems (BAS) via RS-485 Modbus or the Nexa® platform through Wi-Fi.
View full details

Collapsible content

Additional Details

This Colt™ 4 inch reduced pressure detector backflow preventer assembly is designed to prevent the reverse flow of fire protection substances and non-potable water into the potable water supply due to backsiphonage or backpressure.

This compact, modular assembly is approved for horizontal Z pattern installation and includes a flood sensor with SentryPlus Alert® technology for detecting excessive relief valve discharges.

Primary Use

  • Provides protection to drinking water supplies from dangerous cross-connections in accordance with national plumbing codes and water authority requirements for health-hazard non-potable service applications such as irrigation, fire line, or industrial processing.
  • Monitors unauthorized use of water from the fire protection system.

Features

  • Extremely compact design, 70% lighter than traditional designs.
  • 304 (Schedule 40) stainless steel housing and sleeve.
  • Groove fittings for integral pipeline adjustment and easy installation.
  • Patented link check for lowest pressure loss.
  • Unmatched ease of serviceability with replaceable check disc rubber.
  • Bottom-mounted cast stainless steel relief valve.
  • Metered bypass to detect leakage or theft of water from the fire sprinkler system.
  • Includes OS&Y resilient seated gate valves.
  • Approved for horizontal Z pattern installation.

Flood Sensor & Monitoring

  • Features a flood sensor with SentryPlus Alert® technology to detect continuous discharge from the relief valve.
  • An add-on sensor connection kit is required to activate the flood sensor and enable alerts.
  • Sensor Control Monitor integrates smart devices with BAS via RS‑485 Modbus or the Nexa® platform through Wi-Fi.

A WARNING: It is illegal to use this product in a plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes.

Specifications

  • Product Type: Reduced Pressure Detector Assembly
  • Brand: Colt
  • Model Series: C500
  • Nominal Size: 4 inch
  • Configuration: Z pattern horizontal
  • Housing & Sleeve Material: 304 (Schedule 40) Stainless Steel
  • Valve Type: OSY Resilient Seated Gate Valves
  • Bypass Meter: Gallon per minute (GPM) meter
  • Relief Valve: Bottom-mounted cast stainless steel
  • Check Discs: Reversible silicone or EPDM
  • Elastomers: EPDM, silicone, and Buna 'N'
  • Test Cocks: Lead Free* bronze body, nickel plated
  • Link Checks: Noryl®, stainless steel
  • Pins & Fasteners: 300 Series stainless steel
  • Springs: Stainless steel
  • Maximum Working Pressure: 175 PSI (12.1 bar)
  • Temperature Range: 33°F - 140°F (0.5°C - 60°C)

Certificates & Approvals

  • Approved by Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
  • AWWA C511-97
  • ASSE 1047
  • CSA B64.4
  • UL Classified (OSY Only)
  • FM Approved (OSY Only)

FAQs

What is the primary function of the Colt C500Z-OSY-G-FS backflow preventer?

This backflow preventer is designed to protect potable water supplies from contamination caused by backpressure or backsiphonage from non-potable sources like fire protection systems, irrigation, or industrial processing.

Does this backflow preventer include a flood sensor?

Yes, it includes a SentryPlus Alert® flood sensor on the relief valve to detect excessive water discharges. An add-on connection kit is required to activate the sensor and enable alert notifications.

What kind of shutoff valves are included with this assembly?

This model is equipped with Outside Stem and Yoke (OSY) resilient seated gate valves, which are UL Classified and FM Approved.

What materials are used for the main housing of the C500Z-OSY-G-FS?

The entire valve body and closure sleeve are manufactured from 304 (Schedule 40) stainless steel, offering durability and corrosion resistance.

What is the maximum operating pressure and temperature range for this device?

The maximum working pressure for this assembly is 175 PSI (12.1 bar). It can operate within a temperature range of 33°F to 140°F (0.5°C to 60°C).