- Size: 4 inch
- Weight: 52.0 lb
- Working Pressure: 10 - 175 psi
- Housing Material: 304 Stainless Steel
- Dual-action check module for low- and high-flow
- Prewired supervisory switches
- Flood sensor with SentryPlus Alert® technology
- LEAD FREE certified
- End Connections: IPS Grooved
Description
Description
The 4 inch Ames Deringer 40 Reduced Pressure Zone Backflow Preventer Assembly is designed to protect potable water systems from hazardous contaminants and non-health hazard pollutants due to backpressure or backsiphonage conditions. It features a robust 304 stainless steel housing, integral shutoff valves, and IPS grooved ends for steel pipe. The unit includes patented Dual-action check modules for optimal performance at both low and high flow rates, prewired supervisory switches, and a flood sensor with SentryPlus Alert® technology. With a working pressure range of 10-175 psi and LEAD FREE certification, it ensures reliable and safe operation. Item number D-4040.
Help Me Connect
Help Me Connect
Connections
- This assembly features IPS grooved ends for connection to steel pipe, conforming to AWWA C606.
- Flange adapters are available, conforming to ANSI B16.1 Class 125, for alternative connection methods.

Collapsible content
Additional Details
This 4 inch Ames Deringer™ 40 reduced pressure zone backflow preventer assembly is designed to prevent hazardous contaminants and non-health hazard pollutants from entering a potable water supply system caused by backpressure and/or backsiphonage conditions.
It features integral shutoff valves, grooved ends, and dual-action check modules for high performance.
Features
- Integral shutoff valves designed for indoor or outdoor application
- Constructed with 100% stainless steel housing
- Equipped with tamper-resistant test cocks
- Includes a stainless steel braided wire sensing line
- Features a patented Dual-action™ second check module for poppet action at low flow and swing action at high flow
- Utilizes a balanced chamber relief valve requiring no sliding seals
- Poppet action first check for more reliable relief valve closure
- Comes with prewired supervisory switches
- Includes a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve
- Available with flange adapters
- Features IPS grooved ends
Specifications
- Size: 4 inch
- Model: Deringer™ 40
- Working Pressure: 10 - 175 psi
- Temperature Range: 33°F - 140°F
Materials
- Valve Housing: 304 Stainless Steel
- Valve Cover: 304 Stainless Steel
- SOV Disks: EPDM/304SS
- SOV Shafts: 304 Stainless Steel
- RV Spring: 302 Stainless Steel
- SOV Bearings: PTFE Fluoropolymer/Bronze
- Non-wetted Bolts: Grade 8 Zinc Plated
- Check Disks: Silicone (NSF)
- Wetted Fasteners: 18-8 Stainless Steel
- RV Housing: 304 Stainless Steel
- Check Springs: 17-7 Stainless Steel
- Check Pins: 17-7/18-8 Stainless Steel
- Check Seats: Noryl® Polymer (NSF)
- O-rings: Buna-N (NSF)
- RV Hose: Braided Stainless Steel Wire
Connections
- End Connections: IPS Groove for Steel Pipe (AWWA C606)
- Flange Adapters: ANSI B16.1 Class 125
Certificates & Approvals
- AWWA C511-07 Compliant
- ANSI/NSF/CAN 61
- UL Certified Health Effects
- UL Certified to ANSI/NSF/CAN 372
- LEAD FREE
- FM Approved
- ASSE 1013
FAQs
What is the primary function of the Ames Deringer 40 Reduced Pressure Zone Backflow Preventer?
Its primary function is to prevent hazardous contaminants and non-health hazard pollutants from entering a potable water supply system, protecting against backpressure and backsiphonage conditions.
What material is the valve housing made from?
The valve housing is constructed entirely of 304 Stainless Steel, ensuring durability and corrosion resistance.
What are the recommended operating pressure and temperature ranges for this assembly?
This backflow preventer is designed for a working pressure range of 10 to 175 psi and a temperature range of 33°F to 140°F.
Does this backflow preventer include any smart monitoring features?
Yes, it includes a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve, and comes with prewired supervisory switches.
What type of end connections does the 4 inch Deringer 40 assembly have?
The assembly features IPS grooved ends, primarily designed for connection to steel pipe. Flange adapters conforming to ANSI B16.1 Class 125 are also available.