4 LF957RPDA-OSY-CFM-FS
Item Number: F122721Brand - Watts
Couldn't load pickup availability
- 4 inch Lead Free Reduced Pressure Detector Assembly
- Weight: 278.0 lb
- UL Classified and FM Approved OSY Shutoff Valves
- 304 (Schedule 40) Stainless Steel Housing & Sleeve
- Maximum Working Pressure: 175 PSI
- Temperature Range: 33°F - 110°F
- Flood Sensor with SentryPlus Alert® Technology
- Cubic Feet Meter bypass for leak detection
- Extremely compact and lightweight design
Description
Description
Help Me Connect
Help Me Connect
Connections
This 4 inch reduced pressure detector assembly features UL Classified and FM Approved outside stem and yoke (OSY) resilient seated gate valves with 150 pound ANSI/AWWA CL D flanged connections for reliable integration into your piping system. The design accommodates horizontal pattern installation.
Flood Sensor Activation
The integrated flood sensor requires an add-on sensor connection kit to become active and communicate alerts. Without this kit, the sensor remains passive and cannot transmit signals to other devices. Connection kit options include those compatible with BMS (Building Management Systems), cellular communication, and the Sensor Control Monitor for integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.

Collapsible content
Additional Details
This 4 inch Lead Free Reduced Pressure Detector Backflow Preventer Assembly (LF957RPDA) provides protection to potable water systems from contamination due to backpressure or backsiphonage, specifically in health hazard applications. It is approved for horizontal pattern installation and monitors for unauthorized water use from fire protection systems.
The assembly includes a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve, providing alerts to facility personnel to limit flooding and damage.
Features
- Lead Free* construction to comply with Lead Free* installation requirements
- Extremely compact design, approximately 70% lighter than traditional designs
- Housing and sleeve constructed from 304 (Schedule 40) stainless steel
- Groove fittings allow integral pipeline adjustment
- Patented torsion spring check provides lowest pressure loss
- Unmatched ease of serviceability with replaceable check disc rubber
- UL Classified and FM Approved outside stem and yoke (OSY) resilient seated gate valves with 150 pound ANSI/AWWA CL D flanged connections
- Bottom mounted corrosive resistant pressure relief valve reduces clearance requirements
- Metered bypass with a cubic feet meter to detect leakage or theft of water from the fire sprinkler system
- Flood sensor on relief valve for detection of continuous discharge
- Flood alert feature activated with an add-on sensor connection kit, compatible with BMS and cellular network communication
- Integrates with the Sensor Control Monitor to deliver maintenance alerts to BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi
An add-on connection kit is required to activate the flood sensor. Without the connection kit, the sensor is a passive component that has no communication with any other device.
Specifications
- Product Type: Reduced Pressure Detector Assembly
- Size: 4 inch
- Construction: Lead Free*
- Housing & Sleeve Material: 304 (Schedule 40) Stainless Steel
- Elastomers: EPDM, Silicone, Buna 'N'
- Torsion Spring Checks: Noryl®, Stainless Steel
- Check Discs: Reversible Silicone or EPDM
- Test Cocks: Lead Free* Bronze Body
- Pins & Fasteners: 300 Series Stainless Steel
- Springs: Stainless Steel
- Shutoff Valves: UL Classified and FM Approved OSY Resilient Seated Gate Valves, Flanged
- Bypass Meter: Cubic Feet Meter (CFM)
Performance
- Temperature Range: 33°F - 110°F (0.5°C - 43°C)
- Maximum Working Pressure: 175 PSI (12.1 bar)
Certificates & Approvals
- Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
- AWWA C511-97
- ASSE 1047
- CSA B64.4
- UL Classified
- FM Approved
- NSF Certified to NSF/ANSI 372