4 LFC500-DOSY-LM-FS

Item Number: F0425255
Skip to product information
1 of 2
Regular price $12,128.99
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • 4 Inch Lead Free Reduced Pressure Detector Assembly
  • Weight: 275.0 lb
  • Type 304 Stainless Steel Housing & Sleeve
  • Domestic OSY Resilient Seated Gate Valves
  • Includes Flood Sensor with SentryPlus Alert Technology
  • Bypass without meter for leak/theft detection
  • Maximum Operating Pressure: 175 psi
  • Temperature Range: 33°F to 110°F
  • Compact and lightweight design

Description

The Colt 4 inch Lead Free Reduced Pressure Detector Assembly, SKU F0425255, protects potable water systems from contamination in health-hazard applications, such as fire sprinkler systems. This assembly features a durable Type 304 stainless steel housing, domestic OSY resilient seated gate valves, and a corrosive-resistant bottom-mounted relief valve. An integrated flood sensor with SentryPlus Alert technology detects excessive water discharge, enhancing system safety. Its compact and lighter design simplifies installation and service. This backflow preventer operates within a temperature range of 33°F to 110°F and withstands up to 175 psi maximum working pressure. Item number F0425255.

Help Me Connect

This Colt 4 inch Lead Free Reduced Pressure Detector Backflow Preventer Assembly is designed for health-hazard cross-connections, primarily to protect potable water supplies from contamination originating from fire sprinkler systems or other non-potable sources.

Connections

  • It connects into the main water line via its domestic outside stem and yoke (OSY) resilient seated gate valves.
  • The integrated flood sensor with SentryPlus Alert® technology requires an add-on connection kit (not included) for active communication and to send alerts regarding potential flooding events.
  • Connection kit options include those for Building Management Systems (BMS), cellular communication, or the Sensor Control Monitor, which enables integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.
View full details

Collapsible content

Additional Details

This Colt™ 4 inch Lead Free Reduced Pressure Detector Backflow Preventer Assembly is designed to prevent the reverse flow of fire protection substances and water of non-potable quality from being pumped or siphoned into the potable water supply due to backsiphonage and/or backpressure. It is ideal for protection at cross-connections identified as health hazards, such as on fire sprinkler systems and from other contaminants found at the service line entrance.

This compact modular design consists of a stainless steel body with a quick access sleeve, link check valves, domestic outside stem and yoke (OSY) resilient seated gate valves, test cocks, and a corrosive resistant bottom-mounted pressure relief valve. The assembly comes furnished with a bypass without a meter to detect underground leaks and unauthorized water use. This backflow assembly contains a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. When paired with an add-on connection kit, the sensor is activated to relay alerts for potential flooding events.

Features

  • Provides protection to the potable water system from contamination in accordance with national plumbing codes
  • Utilized in health-hazard applications to protect against backsiphonage, backpressure, and the fouling of either check valve
  • Features Lead Free* construction to comply with Lead Free* installation requirements
  • Includes a flood sensor with SentryPlus Alert® technology to detect continuous discharge from the relief valve
  • Flood sensor relays a signal that triggers a multichannel alert (call, email, text) to notify personnel about potential flooding (with add-on sensor connection kit)
  • Extremely compact design and 70% lighter than traditional designs
  • Type 304 (Schedule 40) stainless steel housing and sleeve
  • Groove fittings for integral pipeline adjustment
  • Patented link check for lowest pressure loss
  • Unmatched ease of serviceability with replaceable check disc rubber
  • Available with domestic OSY resilient seated gate valves
  • Bottom-mounted cast stainless steel relief valve
  • Bypass without a meter to detect leakage or theft of water from the fire sprinkler system
  • Includes an integrated supervisory switch as an option on each gate valve of the OS&Y model

An add-on connection kit is required to activate the flood sensor. Without the connection kit, the flood sensor is a passive component and will not communicate with any other device.

Specifications

  • Size: 4 inch
  • Body Material: Type 304 (Schedule 40) Stainless Steel
  • Housing & Sleeve Material: Type 304 (Schedule 40) Stainless Steel
  • Elastomer Materials: EPDM, Silicone, Buna-N
  • Link Check Materials: Noryl®, Stainless Steel
  • Check Disc Materials: Reversible Silicone or EPDM
  • Test Cock Material: Lead Free* Bronze Body
  • Pins & Fastener Material: 300 Series Stainless Steel
  • Spring Material: Stainless Steel
  • Shutoff Valves: Domestic Outside Stem and Yoke (OSY) Resilient Seated Gate Valves
  • Bypass: Less Meter
  • Flood Detection: Integrated Flood Sensor with SentryPlus Alert® Technology
Performance
  • Maximum Working Pressure: 175 psi (12.1 bar)
  • Temperature Range: 33°F - 110°F (0.5°C - 43°C)
Certifications & Approvals
  • Lead Free*
  • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
  • AWWA C511-97
  • ASSE 1047
  • CSA B64.4
  • UL Classified**
  • FM Approved**
  • NSF Certified to NSF/ANSI 372

FAQs

What is the primary purpose of this backflow preventer?

This backflow preventer assembly is designed to protect potable water systems from contamination by preventing the reverse flow of non-potable water and fire protection substances caused by backsiphonage or backpressure in health-hazard applications.

What type of shutoff valves does this assembly include?

This assembly features domestic outside stem and yoke (OSY) resilient seated gate valves. These valves are UL Classified and FM Approved, ensuring reliability and compliance.

What materials are used for the main housing and sleeve?

The housing and sleeve are constructed from durable Type 304 (Schedule 40) stainless steel. This material provides excellent corrosion resistance and strength for long-term performance.

How does the flood sensor function?

The integrated flood sensor with SentryPlus Alert® technology detects excessive water discharges from the relief valve. To activate communication and relay alerts for potential flooding events, an add-on connection kit (sold separately) is required.

What is the maximum operating pressure and temperature range for this device?

The backflow preventer has a maximum operating pressure of 175 psi (12.1 bar). It is designed to operate effectively within a temperature range of 33°F to 110°F (0.5°C to 43°C).