- Size: 6 inch
- Main Valve Body: Ductile Iron ASTM A536
- Bypass Meter: Gallon Meter
- End Connections: Grooved (AWWA C606)
- Maximum Working Water Pressure: 175 PSI
- Maximum Working Water Temperature: 140°F
- Detects leaks and unauthorized water use
- Approved for horizontal or vertical installation
- ASSE® Listed 1048
- NSF/ANSI/CAN 61 Compliant
Description
Description
The Zurn Wilkins Model 350DA is a 6-inch Double Check Detector Assembly designed for fire protection water lines. It safeguards potable water from backsiphonage and backpressure in low health hazard applications. Constructed with a durable ductile iron body, this assembly features grooved end connections and a metered bypass system to detect leaks and unauthorized water usage, reducing maintenance costs. It is approved for both horizontal and vertical installation, offering versatility. This backflow preventer meets rigorous industry standards, including ASSE® 1048 and NSF/ANSI/CAN 61, ensuring reliable performance.
Help Me Connect
Help Me Connect
Installation & Connections
- This 6-inch backflow preventer features grooved end connections designed to comply with AWWA C606 standards for steel piping systems.
- The assembly is approved for installation in both horizontal and vertical positions.
- For proper function and maintenance access, it must be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains, ensuring sufficient side clearance.

Collapsible content
Additional Details
The Zurn Wilkins Model 350DA Double Check Detector Assembly is designed for installation on water lines in fire protection systems to protect against backsiphonage and backpressure of polluted water.
This 6-inch backflow preventer incorporates a metered bypass system to efficiently detect leaks and unauthorized water use, making it suitable for low health hazard applications.
Application
- Protects potable water supply from backsiphonage and backpressure of polluted water.
- Detects leaks and unauthorized water use via metered bypass.
- Suitable for low health hazard fire protection systems.
Materials
- Main Valve Body: Ductile Iron ASTM A536
- Access Covers: Ductile Iron ASTM A536
- Coatings: NSF Approved fusion epoxy finish
- Internals: Stainless steel, 300 Series and NORYL™
- Fasteners: Stainless Steel, 300 Series
- Elastomers: EPDM (FDA approved) and Buna Nitrile (FDA approved)
- Polymers: NORYL™
- Springs: Stainless Steel, 300 Series
Features
- Zurn Wilkins Compound Check provides low headloss and reliable performance.
- Approved for both horizontal and vertical installation.
- Designed for lowest lifecycle costs in the backflow industry.
- Leak and unauthorized water use detection decreases risk of damage and unnecessary costs.
Specifications
- Size: 6 inch
- Main Valve Body Material: Ductile Iron ASTM A536
- Access Covers Material: Ductile Iron ASTM A536
- Coatings: NSF Approved fusion epoxy finish
- Internals Material: Stainless steel, 300 Series, NORYL™
- Fasteners Material: Stainless Steel, 300 Series
- Elastomers: EPDM (FDA approved), Buna Nitrile (FDA approved)
- Polymers: NORYL™
- Springs Material: Stainless Steel, 300 Series
- Maximum Working Water Pressure: 175 PSI
- Maximum Working Water Temperature: 140°F
- Hydrostatic Test Pressure: 350 PSI
- End Connections: Grooved (AWWA C606)
- Bypass Meter: Gallon Meter
Certificates & Approvals
- ASSE® Listed 1048
- CSA® Certified B64.5
- AWWA Compliant C510, C550
- UL® Classified
- C-UL® Classified
- FM® Approved
- NYC MEA 147-99-M Vol 4
- Approved by Foundation for Cross Connection Control and Hydraulic Research (University of Southern California)
- Meets NSF/ANSI/CAN 61 (0.25% Max Weighted Average Lead Content)
FAQs
What is the primary purpose of the Zurn Wilkins Model 350DA Double Check Detector Assembly?
It is designed to protect potable water supply lines in fire protection systems from backsiphonage and backpressure of non-potable water, specifically in low health hazard applications.
What type of bypass system is included with this Zurn Wilkins 350DA assembly?
This model features a metered bypass system with a gallon meter. This system detects leaks and unauthorized water use, helping to prevent unnecessary costs.
Can the Zurn Wilkins 350DA be installed in any orientation?
Yes, the assembly is approved for installation in both horizontal and vertical positions, providing flexibility for various site conditions.
What are the main body and internal materials of this backflow preventer?
The main valve body and access covers are made of ductile iron ASTM A536 with an NSF approved fusion epoxy finish. Internal components, fasteners, and springs are constructed from 300 Series stainless steel and NORYL™.
What are the end connections for this 6-inch Zurn Wilkins 350DA?
This 6-inch model comes with grooved end connections, designed to comply with AWWA C606 standards for steel piping systems.
Related Products
1
/
of
2