6 C500N-BFG-G-FS

Item Number: F0191467
Skip to product information
1 of 1
Regular price $18,077.44
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Nominal Size: 6 inch
  • Weight: 285.0 lb
  • Assembly Type: Reduced Pressure Detector Backflow Preventer
  • Housing Material: 304 (Schedule 40) Stainless Steel
  • Shutoff Valves: Grooved Gear Operated Butterfly with Tamper Switch
  • Connections: Grooved Inlet and Outlet
  • Flood Detection: SentryPlus Alert® Technology Flood Sensor
  • Maximum Working Pressure: 175 PSI
  • Approved for Horizontal N Pattern Installation

Description

This 6 inch Colt C500N-BFG-G-FS Reduced Pressure Detector Backflow Preventer Assembly protects potable water from dangerous cross-connection contamination. It prevents reverse flow of fire protection substances and non-potable water due to backsiphonage or backpressure. Featuring a compact modular design, it includes a 304 stainless steel body, grooved gear operated butterfly valves with tamper switches, and a bottom-mounted stainless steel relief valve. A gallon per minute meter detects leaks or unauthorized water use. The integrated SentryPlus Alert® flood sensor detects excessive relief valve discharge and requires an add-on connection kit for active alert functionality. Approved for horizontal N pattern installation and rated for 175 PSI maximum working pressure. Item number F0191467.

Help Me Connect

Connections

  • This assembly features grooved inlet and outlet connections for straightforward pipe alignment and installation.

Flood Sensor Activation

The integrated flood sensor requires an add-on connection kit to become active and relay alerts for potential flooding events. Connection kit options allow for integration with various systems:

  • Building Management Systems (BMS)
  • Cellular communication
  • Sensor Control Monitor for integration with Building Automation Systems (BAS) via RS‑485 Modbus or the Nexa® platform through Wi‑Fi.
View full details

Collapsible content

Additional Details

This Colt™ 6 inch reduced pressure detector backflow preventer assembly is designed to prevent the reverse flow of fire protection substances and water of non-potable quality from being pumped or siphoned into the potable water supply due to backsiphonage and or backpressure.

This compact modular design is approved for horizontal N pattern installation. It consists of a stainless steel body with a quick access sleeve, torsion spring check valves, grooved gear operated butterfly valves with tamper switch, test cocks, and a corrosive resistant bottom mounted pressure relief valve. It comes furnished with a gallon per minute meter to detect underground leaks and unauthorized water use. This backflow assembly contains a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. When paired with an add‑on connection kit, the sensor is activated to relay alerts for potential flooding events. Connection kit options include BMS, cellular communication, and the Sensor Control Monitor which enables integration with BAS via RS‑485 Modbus or the Nexa® platform through Wi‑Fi.

A WARNING: It is illegal to use this product in a plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes.

Specifications

  • Assembly Type: Reduced Pressure Detector Backflow Preventer
  • Nominal Size: 6 inch
  • Configuration: Horizontal N pattern
  • Housing & Sleeve Material: 304 (Schedule 40) Stainless Steel
  • Shutoff Valves: Grooved Gear Operated Butterfly Valves with Tamper Switch
  • Inlet Connection: Grooved
  • Outlet Connection: Grooved
  • Detector: Gallon Per Minute Meter
  • Relief Valve: Bottom Mounted Cast Stainless Steel
  • Test Cocks: Lead Free* Bronze Body, Nickel Plated
  • Elastomers: EPDM, Silicone, Buna 'N'
  • Link Checks: Noryl®, Stainless Steel
  • Check Discs: Reversible Silicone or EPDM
  • Pins & Fasteners: 300 Series Stainless Steel
  • Springs: Stainless Steel
  • Flood Sensor: Yes, with SentryPlus Alert® Technology
  • Temperature Range: 33°F - 140°F (0.5°C ~ 60°C)
  • Maximum Working Pressure: 175 PSI (12.1 bar)

Certificates & Approvals

  • Approved by Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
  • AWWA C511-97
  • ASSE 1047
  • CSA B64.4
  • UL Classified (BFG)
  • FM Approved (BFG)

FAQs

What is the primary function of the Colt C500N-BFG-G-FS assembly?

This assembly is designed to protect potable water supplies by preventing the reverse flow of fire protection substances and non-potable water, often caused by backsiphonage or backpressure.

What material is used for the main housing of this backflow preventer?

The main housing and sleeve of this backflow preventer assembly are constructed from durable 304 (Schedule 40) stainless steel.

Does this model include a flood sensor, and how does it work?

Yes, it includes a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. An add-on connection kit is required to activate the sensor for real-time alerts.

What type of shutoff valves are installed on this 6-inch assembly?

This assembly is equipped with UL Classified and FM Approved grooved gear operated butterfly valves that include a tamper switch for enhanced security and monitoring.

What are the connection types for the inlet and outlet of this backflow preventer?

Both the inlet and outlet connections for this 6-inch Reduced Pressure Detector Backflow Preventer are grooved, allowing for easy installation and pipeline alignment.