6 LFC500N-DOSY-LM-FS

Item Number: F0425292
Skip to product information
1 of 1
Regular price $19,950.75
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Size: 6 inch
  • Weight: 492.0 lb
  • Configuration: Horizontal N Pattern
  • Maximum Working Pressure: 175 psi
  • Temperature Range: 33°F - 110°F
  • Housing & Sleeve Material: Type 304 (Schedule 40) stainless steel
  • Features SentryPlus Alert® flood sensor
  • Domestic outside stem and yoke (OSY) gate valves
  • AWWA C511-97, ASSE 1047, CSA B64.4 Approved

Description

This Colt 6 inch Lead Free Reduced Pressure Detector Backflow Preventer Assembly, SKU F0425292, is engineered for health hazard applications to protect potable water supplies from contamination. It effectively prevents backsiphonage and backpressure from fire protection systems. The unit features a compact, horizontal N pattern design with a durable Type 304 stainless steel body and grooved connections. It includes a SentryPlus Alert® technology flood sensor to detect relief valve discharge, along with domestic OSY gate valves and a meter-less bypass for leak detection. This assembly is approved by AWWA C511-97, ASSE 1047, CSA B64.4, UL, FM, and NSF/ANSI 372 for reliable, lead-free operation.

Help Me Connect

Connections

  • This 6 inch backflow preventer assembly features grooved end connections.
  • The inlet and outlet are designed to connect to compatible 6 inch grooved piping systems.
View full details

Collapsible content

Additional Details

This Colt™ 6 inch lead free reduced pressure detector backflow preventer assembly is designed to prevent the reverse flow of fire protection substances and non-potable water into the potable water supply, addressing both backsiphonage and backpressure risks.

It features a compact modular design with a stainless steel body, suited for health hazard applications in fire sprinkler systems.

Key Features

  • Equipped with SentryPlus Alert® technology flood sensor to detect continuous discharge from the relief valve.
  • Includes an add-on sensor connection kit for extended flood monitoring capabilities via BMS, cellular, or the Nexa® platform.
  • Constructed with a Type 304 (Schedule 40) stainless steel housing and sleeve.
  • Features domestic outside stem and yoke (OSY) resilient seated gate valves.
  • Designed for horizontal N pattern installation.
  • Utilizes link check valves and a corrosive resistant bottom mounted pressure relief valve.
  • Bypass without a meter helps detect underground leaks and unauthorized water use.
  • Extremely compact design, up to 70% lighter than traditional models.
  • Groove fittings allow for integral pipeline adjustment and unlatched ease of serviceability.
  • No special tools required for servicing.

Notice: An add-on or connection kit is required to activate the flood sensor. Without the connection kit, the flood sensor is a passive component and will not communicate with any other device.

Specifications

  • Size: 6 inch
  • Configuration: Horizontal N Pattern
  • Maximum Working Pressure: 175 psi (12.1 bar)
  • Temperature Range: 33°F - 110°F (0.5°C – 43°C)

Materials

  • Housing & Sleeve: Type 304 (Schedule 40) stainless steel
  • Elastomers: EPDM, silicone, and Buna-N
  • Link Checks: Noryl®, stainless steel
  • Check Discs: Reversible silicone or EPDM
  • Test Cocks: Lead Free* bronze body
  • Pins & Fasteners: 300 Series stainless steel
  • Springs: Stainless steel

Certificates & Approvals

  • AWWA C511-97
  • ASSE 1047
  • CSA B64.4
  • UL Classified (**BFG & OSY Only)
  • FM Approved (**BFG & OSY Only)
  • NSF Certified to NSF/ANSI 372

FAQs

What is the primary function of this backflow preventer?

This Colt 6 inch Lead Free Reduced Pressure Detector Backflow Preventer Assembly is designed to prevent the reverse flow of non-potable water and fire protection substances into the potable water supply, protecting against both backsiphonage and backpressure. It is used in health hazard applications.

What type of flood detection system does this assembly include?

It includes a SentryPlus Alert® technology flood sensor on the relief valve, designed to detect continuous or excessive discharge. An add-on connection kit is required to activate the sensor and enable communication.

What are the key construction materials of this backflow preventer?

The housing and sleeve are constructed from Type 304 (Schedule 40) stainless steel. Other components include EPDM, silicone, and Buna-N elastomers, Noryl® and stainless steel link checks, and Lead Free* bronze body test cocks.

What are the installation requirements for this model?

This specific model is designed for horizontal N pattern installation. It features grooved end connections, which are compatible with 6 inch grooved piping systems.

What certifications and approvals does this backflow preventer hold?

This assembly is approved by AWWA C511-97, ASSE 1047, CSA B64.4, UL Classified, FM Approved (for OSY models), and NSF Certified to NSF/ANSI 372 for lead-free compliance.