6 LFC500Z-BFG-C-FS

Item Number: F0124675
Skip to product information
1 of 1
Regular price $19,924.08
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Size: 6 inch
  • Weight: 285.0 lb
  • Installation: Horizontal Z Pattern
  • Body Material: Type 304 (Schedule 40) Stainless Steel
  • Shutoff Valves: Grooved Gear Operated Butterfly with Tamper Switch
  • Flood Sensor: SentryPlus Alert® Technology
  • Bypass: CFM Meter for Leakage Detection
  • Maximum Operating Pressure: 175 PSI
  • Lead Free: Yes (<0.25% lead content)

Description

The Colt 6 inch LFC500Z-BFG-C-FS Lead Free Reduced Pressure Detector Assembly protects potable water systems from contamination and reverse flow in fire protection applications. Its compact design features Type 304 stainless steel construction, grooved butterfly shutoff valves with tamper switches, and a Z pattern horizontal installation. The integrated flood sensor with SentryPlus Alert® technology detects excessive water discharge, and a CFM meter monitors for leaks or unauthorized water use. This assembly is lead-free, UL and FM approved, ensuring compliance and reliability for critical backflow prevention needs. Item number F0124675.

Help Me Connect

Installation Orientation

This backflow preventer assembly is specifically designed and approved for horizontal Z pattern installation.

Shutoff Valves

It includes grooved gear operated butterfly valves with tamper switches for connection to the pipeline. These grooved connections facilitate integral pipeline adjustment.

Flood Sensor Connectivity

The integrated flood sensor requires an add-on connection kit for activation to relay alerts. Connection kit options support various communication methods:

  • BMS (Building Management System)
  • Cellular communication
  • Sensor Control Monitor for integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.
View full details

Collapsible content

Additional Details

The Colt 6 inch LFC500Z-BFG-C-FS Lead Free Reduced Pressure Detector Assembly is designed to protect potable water systems from contamination due to backsiphonage and backpressure. This assembly is commonly used in health-hazard applications to prevent the reverse flow of fire protection substances and non-potable water into the municipal water supply.

Key Features

  • Lead Free construction, with wetted surfaces containing less than 0.25% lead by weight.
  • Extremely compact design, approximately 70% lighter than traditional designs.
  • Approved for horizontal Z pattern installation.
  • Includes grooved gear operated butterfly valves with tamper switches.
  • Groove fittings for integral pipeline adjustment.

Flood Detection & Alerting

  • Features a flood sensor on the relief valve with SentryPlus Alert® technology to detect continuous discharge.
  • Monitors for unauthorized use of water from the fire protection system with a metered bypass and CFM meter.
  • Option to add a connection kit for advanced alerts including integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.

Construction & Materials

  • Housing and sleeve are constructed from Type 304 (Schedule 40) stainless steel.
  • Consists of two independent Link Check modules with reversible elastomer discs.
  • Bottom-mounted cast stainless steel relief valve.
  • Bronze body nickel plated test cocks.
  • Replaceable check disc rubber for ease of serviceability.

Specifications

  • Size: 6 inch
  • Product Type: Reduced Pressure Detector Assembly
  • Installation Pattern: Horizontal Z Pattern
  • Bypass Meter: CFM Meter
  • Flood Sensor: Yes, SentryPlus Alert® Technology

Materials

  • Housing & Sleeve Material: Type 304 (Schedule 40) Stainless Steel
  • Elastomers: EPDM, Silicone, Buna-N
  • Link Check Material: Noryl®, Stainless Steel
  • Check Disc Material: Reversible Silicone or EPDM
  • Test Cocks: Lead Free* Bronze Body, Nickel Plated
  • Pins & Fasteners: 300 Series Stainless Steel
  • Springs: Stainless Steel
  • Lead Content: Wetted surfaces contain less than 0.25% lead

Performance

  • Maximum Working Pressure: 175 PSI (12.1 bar)
  • Temperature Range: 33°F - 110°F (0.5°C – 43°C)

Certificates & Approvals

  • UL Classified
  • FM Approved
  • ASSE 1047
  • CSA B64.4
  • NSF Certified to NSF/ANSI 372
  • AWWA C511-97

FAQs

What type of installation is supported by this backflow preventer?

This Colt LFC500Z-BFG-C-FS assembly is approved for horizontal Z pattern installation. It is crucial to install it according to the specified orientation for proper function and compliance.

What does "Lead Free" mean for this backflow assembly?

"Lead Free" means that the wetted surfaces of this product, which come into contact with consumable water, contain less than 0.25% of lead by weight. This ensures compliance with modern lead-free installation requirements for potable water systems.

How does the flood sensor function on this LFC500Z-BFG-C-FS model?

The assembly includes a flood sensor with SentryPlus Alert® technology on the relief valve to detect excessive water discharges. When paired with an add-on connection kit, the sensor can trigger multichannel alerts (call, email, text) for potential flooding events.

What kind of shutoff valves are included with this assembly?

This model is equipped with UL Classified and FM Approved grooved gear operated butterfly valves that feature tamper switches. These valves allow for pipeline adjustment and security.

Can this backflow preventer be integrated into a building management system?

Yes, with an add-on sensor connection kit, the flood sensor can integrate with Building Automation Systems (BAS) via RS-485 Modbus or the Nexa® platform through Wi-Fi, enabling centralized monitoring.