6 M500N-OSY-GPM

Item Number: 0191131
Skip to product information
1 of 1
Regular price $22,456.49
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Size: 6 inch
  • Weight: 557.0 lb
  • Housing & Sleeve Material: 304 (Schedule 40) Stainless Steel
  • Maximum Working Pressure: 175 PSI
  • Installation: Horizontal N Pattern
  • Includes: Gallon per minute meter
  • Shutoff Valves: UL/FM OSY Gate Valves
  • Design: Extremely Compact, 70% Lighter
  • Certifications: ASSE 1047, CSA B64.4, cULus, FM, UL

Description

The 6 inch Maxim M500N Reduced Pressure Detector Backflow Preventer Assembly by Ames Fire & Waterworks provides critical protection for potable water supplies. Designed for health-hazard non-potable applications like fire sprinkler systems, it prevents dangerous cross-connections and reverse flow. This compact, 70% lighter assembly features a durable 304 stainless steel housing, UL/FM OSY shutoff valves, and grooved couplings for easy installation. A built-in gallon per minute meter helps detect leaks and unauthorized water usage. It is approved for horizontal N pattern installations and certified by ASSE 1047, CSA B64.4, cULus, FM, and UL. Item number 0191131.

Help Me Connect

Connections

  • This assembly features grooved couplings for both the inlet and outlet gate connections.
  • Groove fittings facilitate integral pipeline adjustment and simplify installation with compatible grooved piping systems.
  • It is equipped with UL and FM outside stem and yoke (OSY) resilient seated gate valves for secure shutoff.
View full details

Collapsible content

Additional Details

This 6 inch Maxim M500N Reduced Pressure Detector Backflow Preventer Assembly is engineered to safeguard drinking water supplies from dangerous cross-connections, preventing the reverse flow of non-potable substances into potable water systems.

It is specifically designed for health-hazard non-potable service applications, such as fire line protection, and includes a gallon per minute meter to monitor unauthorized water use or detect underground leaks in fire protection systems.

Features

  • Extremely Compact Design, approximately 70% lighter than traditional designs.
  • Maintains system integrity with a 304 (Schedule 40) Stainless Steel Housing & Sleeve.
  • Groove fittings allow for integral pipeline adjustment and simplified installation.
  • Patented Link Check modules provide the lowest pressure loss.
  • Offers unmatched ease of serviceability with a single access cover.
  • Equipped with UL and FM outside stem and yoke resilient seated gate valves.
  • Approved for horizontal N pattern installations.
  • Features replaceable check disc rubber for easy maintenance.
  • Includes bronze body nickel plated test cocks and a bottom mounted stainless steel relief valve.

WARNING: It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dish-washing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes.

Specifications

  • Product Type: Reduced Pressure Detector Backflow Preventer Assembly
  • Model Series: Maxim™ M500N
  • Nominal Size: 6 inch
  • Meter Type: Gallons per minute
  • Installation Orientation: Horizontal, N Pattern

Materials

  • Housing & Sleeve: 304 (Schedule 40) Stainless Steel
  • Elastomers: EPDM, Silicone, Buna 'N'
  • Link Checks: Noryl®, Stainless Steel
  • Check Discs: Reversible Silicone or EPDM
  • Test Cocks Body: Lead Free* Bronze
  • Pins & Fasteners: 300 Series Stainless Steel
  • Springs: Stainless Steel
  • Relief Valve: Stainless Steel (bottom mounted)

Performance

  • Maximum Working Pressure: 175 PSI (12.06 bar)
  • Temperature Range: 33°F - 110°F (5°C - 43°C)

Certificates & Approvals

  • ASSE: 1047
  • CSA: B64.4
  • cULus: Classified
  • FM: Approved (BFG & OSY Only)
  • UL: Approved (OSY)

FAQs

What is the primary use of this backflow preventer assembly?

This 6 inch Maxim M500N Reduced Pressure Detector Backflow Preventer Assembly is primarily used to protect drinking water supplies from contamination caused by dangerous cross-connections in health-hazard non-potable service applications, such as fire sprinkler systems.

What type of meter is included with this assembly?

The assembly comes furnished with a gallon per minute meter. This meter is used to detect underground leaks and monitor for any unauthorized water use within the fire protection system.

What certifications does this backflow preventer hold?

The Maxim M500N is ASSE 1047, CSA B64.4, cULus Classified, FM Approved (for BFG & OSY models), and UL Approved (for OSY models).

What are the main material components of the housing and sleeve?

The entire valve body and closure sleeve of this backflow preventer assembly are manufactured from durable 304 (Schedule 40) stainless steel, ensuring longevity and resistance to corrosion.

What is the maximum operating pressure and temperature range for this unit?

This assembly has a maximum working pressure of 175 PSI (12.06 bar). It is designed to operate within a temperature range of 33°F to 110°F (5°C to 43°C).