8 709DCDA-OSY-GPM

Item Number: 0387070
Skip to product information
1 of 1
Regular price $43,073.25
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Watts

  • Nominal Size: 8 inch
  • Weight: 1329.0 lb
  • Body Material: Fused epoxy coated cast iron
  • Coating: ArmorTek® for corrosion resistance
  • Maximum Operating Pressure: 175 psi
  • Meter: Gallons per minute meter included
  • Shutoff Valves: OSY (Outside Stem and Yoke) resilient seated
  • Design: Modular check for easy maintenance
  • Certifications: UL Listed, FM Approved, ASSE 1048, AWWA C510

Description

This 8 inch Watts 709DCDA Double Check Detector Assembly Backflow Preventer safeguards potable water lines from contamination by fire protection system substances. Featuring a fused epoxy coated cast iron body with patented ArmorTek® corrosion-resistant coating, it ensures durability. The assembly includes OSY shutoff valves and a gallons per minute meter for detecting leaks and unauthorized water usage. With a maximum operating pressure of 175 psi, its modular design allows for straightforward maintenance. It is UL Listed, FM Approved, ASSE 1048, and AWWA C510 compliant.

Help Me Connect

Primary Connection

  • This double check detector assembly is designed for installation on fire protection systems when connected to a potable water supply.

Functionality

  • It prevents the reverse flow of non-potable fire protection system substances into the potable water line, fulfilling water authority containment requirements.
View full details

Collapsible content

Additional Details

This 8 inch Watts 709DCDA Double Check Detector Assembly prevents the reverse flow of non-health hazard fire protection system substances, such as glycerin wetting agents or stagnant water, from being pumped or siphoned into the potable water supply. It is mandatory for water authority containment requirements and helps detect leaks and unauthorized water use.

Features

  • Fused epoxy coated cast iron body construction
  • Replaceable bronze seats
  • Provides maximum flow at low pressure drop
  • Compact design for economy combined with performance
  • Design simplicity for easy maintenance
  • Features ArmorTek coating technology to resist corrosion of internals
  • Furnished with a gallons per minute meter
  • No special tools required for servicing
  • Modular check design facilitates complete maintenance and assembly access

Advanced Protection

  • Incorporates ArmorTek®, a patented three-part advanced epoxy system, engineered to reduce microbial-induced corrosion (MIC) and protect exposed metal substrate.

NOTICE: The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. Inquire with governing authorities for local installation requirements.

Specifications

  • Body Material: Cast Iron, Fused Epoxy Coated
  • Coating: ArmorTek® (internal and external surfaces)
  • Seat: Bronze
  • Disc Holder: Bronze
  • Trim: Stainless steel
  • Check Valve Discs: Rubber
  • Test Cocks: Bronze

Connections & Operation

  • Shutoff Valves: OSY (Outside Stem and Yoke) resilient seated gate valves
  • Nominal Size: 8 inch
  • Meter: Gallons per minute meter
  • Maximum Operating Pressure: 175 psi (12.06 bar)
  • Continuous Temperature Range: 33°F – 140°F (0.5°C – 60°C)
  • Intermittent Temperature Range: 140°F (60°C)

Certificates & Approvals

  • UL Listed
  • UL Classified
  • FM Approved
  • ASSE 1048
  • AWWA Standard C510
  • Approved by Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California

FAQs

What is the primary purpose of this 8 inch Double Check Detector Assembly?

Its primary purpose is to prevent the reverse flow of non-potable fire protection system substances, such as glycerin wetting agents or stagnant water, from entering the potable water supply line. It is mandatory for water authority containment requirements.

What is ArmorTek® coating technology and why is it important?

ArmorTek® is a patented three-part advanced epoxy system that coats the iron components of the backflow preventer. It is engineered to reduce microbial-induced corrosion (MIC) and protect exposed metal substrate, enhancing the assembly's durability and lifespan.

Does this backflow preventer help detect water leaks?

Yes, this assembly not only detects leaks, with an emphasis on unaccountable water, but also incorporates a gallons per minute meter. This meter allows the water utility to detect underground leaks and identify unauthorized water use, helping to locate illegal taps.

What are the key certifications and approvals for this 709DCDA assembly?

This assembly is UL Listed, UL Classified, and FM Approved, specifically for its resilient seated OSY shutoff valves and test cocks. It also meets the basic requirements of ASSE 1048 and AWWA Std. C510 for Double Check Valves.

What type of shutoff valves are included with this assembly?

The assembly is standardly equipped with resilient seated OSY (Outside Stem and Yoke) shutoff valves. These valves are also UL Classified and FM Approved.