8 957RPDA-DOSY-CFM-FS

Item Number: F113101
Skip to product information
1 of 2
Regular price $23,872.50
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Watts

  • Reduced Pressure Detector Assembly, 8 inch
  • Weight: 610.0 lb
  • Protects potable water systems from contamination
  • 304 (Schedule 40) stainless steel housing and sleeve
  • Flood sensor with SentryPlus Alert technology included
  • UL Classified and FM Approved
  • Maximum Working Pressure: 175 psi
  • Temperature Range: 33°F – 140°F
  • Metered bypass for leak and theft detection

Description

This 8 inch Watts 957RPDA Reduced Pressure Detector Assembly effectively prevents backflow due to backpressure or backsiphonage, safeguarding potable water systems from health hazard contamination. It features a durable 304 stainless steel housing and sleeve, UL Classified and FM Approved OSY resilient seated gate valves, and a metered bypass to detect water leakage or theft. The integrated flood sensor with SentryPlus Alert technology detects excessive relief valve discharges, providing an advanced monitoring solution for fire protection systems. Its compact design also allows for installation in smaller enclosures. Item number F113101.

Help Me Connect

Connections and Connectivity

  • This 8 inch reduced pressure detector assembly features groove fittings, allowing for integral pipeline adjustment and flexible installation.
  • The included flood sensor requires an add-on connection kit (sold separately) for activation, enabling communication with Building Management Systems (BMS), cellular networks, or integration with Building Automation Systems (BAS) via RS-485 Modbus or the Nexa platform through Wi-Fi.
View full details

Collapsible content

Additional Details

This 8 inch reduced pressure detector backflow preventer assembly prevents the reverse flow of liquids due to backpressure or backsiphonage, protecting potable water systems from contamination where a potential health hazard exists.

It is designed for health hazard applications and includes a flood sensor with SentryPlus Alert technology to detect excessive water discharges from the relief valve.

A WARNING: It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes.

Key Features

  • Provides protection to the potable water system from contamination in accordance with national plumbing codes.
  • Extremely compact design and 70% lighter than traditional designs for smaller enclosures.
  • Constructed with a 304 (Schedule 40) stainless steel housing and sleeve.
  • Groove fittings allow integral pipeline adjustment.
  • Features UL Classified and FM Approved domestic outside stem and yoke (OSY) resilient seated gate valves.
  • Patented torsion spring check provides lowest pressure loss and unmatched ease of serviceability.
  • Replaceable check disc rubber for easy maintenance.
  • Bottom mounted cast stainless steel relief valve.
  • Metered bypass with a cubic foot per minute meter detects leakage or unauthorized water use from the fire sprinkler system.
  • Integrated flood sensor with SentryPlus Alert technology detects excessive water discharges from the relief valve.
  • Flood alert feature is activated with an add-on sensor connection kit, compatible with BMS and cellular network communication, and the Sensor Control Monitor for integration with BAS via RS-485 Modbus or Nexa platform by Wi-Fi.

Specifications

  • Product Type: Reduced Pressure Detector Assembly
  • Size: 8 inch
  • Model Series: 957RPDA
  • Pattern: N-pattern
  • Shutoff Valves: Domestic Outside Stem and Yoke (OSY) resilient seated gate valves
  • Bypass Meter: Cubic Feet Meter (CFM)
  • Flood Sensor: Included, SentryPlus Alert technology

Materials

  • Housing & Sleeve: 304 (Schedule 40) stainless steel
  • Elastomers: EPDM, silicone, and Buna 'N'
  • Torsion Spring Checks: Noryl®, stainless steel
  • Check Discs: Reversible silicone or EPDM
  • Test Cocks: Lead Free* bronze body
  • Pins & Fasteners: 300 Series stainless steel
  • Springs: Stainless steel
  • Relief Valve: Bottom mounted cast stainless steel

Pressure - Temperature

  • Temperature Range: 33°F – 140°F (0.5°C – 60°C)
  • Maximum Working Pressure: 175 psi (12.1 bar)

Certificates & Approvals

  • UL Classified
  • FM Approved
  • ASSE 1047
  • CSA B64.4
  • Approved by The Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
  • AWWA C511-97

FAQs

What is the primary function of the Watts 957RPDA backflow preventer?

The Watts 957RPDA backflow preventer is designed to protect potable water systems from contamination by preventing the reverse flow of liquids caused by backpressure or backsiphonage, especially in health hazard applications.

Does this assembly include a flood sensor?

Yes, this assembly includes an integrated flood sensor with SentryPlus Alert technology, which is designed to detect excessive water discharges from the relief valve.

What materials are used for the main housing and sleeve of this backflow preventer?

The main housing and sleeve of the Watts 957RPDA backflow preventer are constructed from durable 304 (Schedule 40) stainless steel.

How does the flood sensor communicate alerts?

To activate the flood sensor's alert feature, an add-on sensor connection kit (sold separately) is required. Once activated, it can relay signals compatible with BMS, cellular networks, or integrate with BAS via RS-485 Modbus or the Nexa platform through Wi-Fi.

What is the maximum operating pressure and temperature range for this device?

The Watts 957RPDA backflow preventer has a maximum working pressure of 175 psi (12.1 bar) and an operating temperature range of 33°F to 140°F (0.5°C to 60°C).