8 957RPDA-DOSY-GPM-FS
Item Number: F113102Brand - Watts
Couldn't load pickup availability
- Nominal Size: 8 inch
- Weight: 610.0 lb
- Maximum Working Pressure: 175 psi
- Housing & Sleeve Material: 304 Stainless steel
- Shutoff Valves: OSY Resilient Seated Gate Valves
- Features: Flood Sensor with SentryPlus Alert® technology
- Bypass Meter: Gallons per Minute (GPM)
- Approvals: UL Classified, FM Approved, ASSE 1047, CSA B64.4
- Application: Health Hazard
- Temperature Range: 33°F - 140°F
Description
Description
Help Me Connect
Help Me Connect
This 8 inch backflow preventer is designed for horizontal N-pattern installation to prevent backpressure and backsiphonage in health hazard applications. Its assembly incorporates OSY (Outside Stem and Yoke) resilient seated gate valves, which typically feature flanged end connections to connect to your pipeline. The stainless steel housing uses groove end connections for easy assembly and maintenance, allowing integral pipeline adjustment.

Collapsible content
Additional Details
This 8 inch reduced pressure detector backflow preventer assembly prevents the reverse flow of liquids due to backpressure or backsiphonage, critical for health hazard applications. It features a compact design, a stainless steel body, and advanced flood detection capabilities.
Construction
- 304 (Schedule 40) stainless steel housing and sleeve with groove end connections.
- Two independent torsion spring check modules and a differential pressure relief valve.
- Torsion spring checks feature reversible elastomer discs for drip-tight closure.
- Bottom mounted cast stainless steel relief valve.
- Lead Free* bronze body test cocks.
- Pins & fasteners are 300 Series stainless steel.
- Springs are stainless steel.
Features
- Extremely compact design, lighter than traditional backflow preventers.
- Patented torsion spring check provides lowest pressure loss.
- Unmatched ease of serviceability with no special tools required.
- Replaceable check disc rubber.
- Metered bypass (gallons per minute meter) to detect leakage or theft of water.
- Integrated flood sensor with SentryPlus Alert® technology detects excessive water discharges from the relief valve.
- Add-on sensor connection kit capable of integration with BMS, cellular communication, or Sensor Control Monitor via RS-485 Modbus or Wi-Fi Nexa® platform.
Connections
- Equipped with UL Classified and FM Approved outside stem and yoke (OSY) resilient seated gate valves for shutoff.
- Groove fittings allow integral pipeline adjustment.
It is illegal to use this product in any plumbing system providing water for human consumption such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes.
Specifications
- Product Type: Reduced Pressure Detector Assembly Backflow Preventer
- Model: 957RPDA-OSY-GPM-FS
- Nominal Size: 8 inch
- Application: Health Hazard
- Installation Pattern: Horizontal N-pattern
- Temperature Range: 33°F - 140°F (0.5°C - 60°C)
- Maximum Working Pressure: 175 psi (12.1 bar)
Materials
- Housing & Sleeve: 304 (Schedule 40) Stainless steel
- Elastomers: EPDM, Silicone, Buna 'N'
- Torsion Spring Checks: Noryl®, Stainless steel
- Check Discs: Reversible Silicone or EPDM
- Test Cocks: Lead Free* Bronze body
- Pins & Fasteners: 300 Series Stainless steel
- Springs: Stainless steel
Features
- Shutoff Valves: UL Classified and FM Approved OSY (Outside Stem and Yoke) resilient seated gate valves
- Bypass Meter: Gallons per minute (GPM)
- Flood Detection: Sensor on relief valve with SentryPlus Alert® technology
- Serviceability: No special tools required
Certificates & Approvals
- AWWA C511-97
- ASSE 1047
- CSA B64.4
- UL Classified
- FM Approved
- Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC) Approved (excluding 10" N-pattern, 6" and 10" Z-pattern installations)