8 C500-NRS-G-FS

Item Number: F0191344
Skip to product information
1 of 1
Regular price $25,821.55
Special Order
When Will it Ship: Contact for Lead Time
Estimated transit time: 2 to 5 Business Days

Brand - Ames

  • Size: 8 inch
  • Weight: 647.0 lb
  • Housing Material: 304 Stainless Steel
  • Maximum Working Pressure: 175 psi
  • Temperature Range: 33°F - 140°F
  • Equipped with SentryPlus Alert® Flood Sensor
  • Features Metered Bypass for Leak Detection
  • Grooved Connections for easy installation and pipeline adjustment
  • Approved to ASSE 1047, CSA B64.4, UL, and FM standards

Description

The Colt 8 inch Reduced Pressure Detector Backflow Preventer Assembly (F0191344) safeguards potable water from contamination in health-hazard cross-connections like fire sprinkler systems. It features a durable 304 stainless steel body, non-rising stem shutoff valves, and grooved connections for easy installation. A SentryPlus Alert® flood sensor detects relief valve discharges, while a gallon per minute meter monitors for leaks. With a maximum working pressure of 175 psi and a compact design, this assembly is approved by ASSE 1047, CSA B64.4, UL, and FM, ensuring reliable performance and compliance.

Help Me Connect

Pipeline Connections

  • This backflow preventer assembly features grooved couplings on both the inlet and outlet.
  • Grooved connections allow for efficient and straightforward installation into a pipeline system.
  • The grooved design also provides flexibility for integral pipeline adjustment during installation.
View full details

Collapsible content

Additional Details

The Colt™ 8 inch Reduced Pressure Detector Backflow Preventer Assembly is designed to protect potable water supplies from dangerous cross-connections, preventing reverse flow of non-potable substances due to backsiphonage or backpressure. It is ideal for health-hazard applications such as fire sprinkler systems, irrigation, and industrial processing where health hazards may exist.

It is illegal to use this product in a plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Consult your local water authority, building, and plumbing codes before installing standard material products.

Construction & Design

  • Features an extremely compact design that is 70% lighter than traditional backflow preventers.
  • Constructed with a 304 (Schedule 40) stainless steel housing and sleeve for durability.
  • Includes two independent Link Check modules with a patented link check for lowest pressure loss.
  • Equipped with resilient seated gate valves with non-rising stems for reliable shutoff.
  • Features a bottom-mounted cast stainless steel relief valve.
  • Groove fittings allow for integral pipeline adjustment and unmatched ease of serviceability.

Monitoring & Alert Capabilities

  • Furnished with a gallon per minute meter to detect leakage or unauthorized water use from the fire sprinkler system.
  • Includes a flood sensor with SentryPlus Alert® technology on the relief valve to detect excessive water discharges.
  • Flood alert feature is activated by an add-on sensor connection kit (required for communication with any device).
  • Supports integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi when connected to a Sensor Control Monitor.

Specifications

  • Model: C500 Reduced Pressure Detector Assembly
  • Size: 8 inch
  • Housing & Sleeve Material: 304 (Schedule 40) Stainless Steel
  • Elastomers: EPDM, Silicone, Buna 'N'
  • Link Check Material: Noryl®, Stainless Steel
  • Check Disc Material: Reversible Silicone or EPDM
  • Test Cock Material: Lead Free* Bronze Body
  • Pins & Fasteners Material: 300 Series Stainless Steel
  • Spring Material: Stainless Steel
  • Valve Type: Resilient Seated Gate Valves with Non-Rising Stem (NRS)
  • Inlet/Outlet Connections: Grooved
  • Maximum Working Pressure: 175 psi (12.1 bar)
  • Temperature Range: 33°F - 140°F (0.5°C ~ 60°C)
  • Weight: 441 lb (200 kg)

Certificates & Approvals

  • Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
  • AWWA C511-97
  • ASSE 1047
  • CSA B64.4
  • UL Classified
  • FM Approved

Configurations

  • Horizontal
  • "Z" pattern horizontal
  • "N" pattern horizontal

FAQs

What is the primary function of this backflow preventer?

The Colt 8 inch Reduced Pressure Detector Backflow Preventer Assembly is designed to protect drinking water supplies by preventing reverse flow of non-potable substances from dangerous cross-connections caused by backsiphonage or backpressure. It's suitable for health-hazard applications like fire sprinkler systems and industrial processing.

What materials are used in the construction of this backflow preventer?

The housing and sleeve are constructed from durable 304 (Schedule 40) stainless steel. Key components like link checks are Noryl® and stainless steel, and test cocks are made from lead-free bronze. Elastomers such as EPDM, silicone, and Buna 'N' are used for seals.

Does this backflow preventer include a flood detection system?

Yes, it is equipped with a SentryPlus Alert® flood sensor on the relief valve to detect excessive water discharges. An add-on sensor connection kit is required to activate the flood alert feature and relay signals to monitoring systems.

What types of connections does this assembly use for installation?

This assembly features grooved inlet and outlet connections. These grooved couplings facilitate easy and efficient installation into a pipeline system and allow for integral pipeline adjustment.

What are the key approvals and certifications for this product?

This Colt C500 assembly is approved by the Foundation for Cross-Connection Control and Hydraulic Research at USC, AWWA C511-97, ASSE 1047, CSA B64.4, UL Classified, and FM Approved, ensuring compliance with industry standards.