Brand - Ames

  • Size: 8 inch
  • Weight: 723.0 lb
  • Body Material: 304 (Schedule 40) Stainless Steel
  • Configuration: N Pattern Horizontal
  • Shutoff Valves: OSY (Outside Stem and Yoke)
  • Includes Flood Sensor with SentryPlus Alert® Technology
  • Maximum Working Pressure: 175 PSI
  • AWWA C511-97, ASSE 1047, CSA B64.4, UL, FM Approved
  • Cubic Feet per Minute Meter for Leak Detection

Description

The Colt™ 8 inch C500 Reduced Pressure Detector Backflow Preventer Assembly with OSY Shutoff Valves prevents contaminated fire protection substances from entering potable water supplies due to backsiphonage or backpressure. This durable assembly features a 304 stainless steel body, an N pattern horizontal configuration, and includes a flood sensor with SentryPlus Alert® technology for continuous discharge detection. It is equipped with a cubic feet per minute meter to monitor unauthorized water use or leaks. Rated for a maximum working pressure of 175 PSI, this assembly is approved by AWWA, ASSE, CSA, UL, and FM.
View full details

Collapsible content

Additional Details

This Colt™ 8 inch reduced pressure detector backflow preventer assembly is designed to prevent the reverse flow of fire protection substances and water of non-potable quality from being pumped or siphoned into the potable water supply due to backsiphonage and/or backpressure.

The assembly comes with a flood sensor featuring SentryPlus Alert® technology to detect continuous discharge from the relief valve, offering advanced monitoring capabilities for fire protection systems. An add-on sensor connection kit is required to activate the flood sensor's alert features.

WARNING

It is illegal to use this product in a plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Always consult your local water authority, building, and plumbing codes before installing.

Features

  • Compact modular design for efficient installation.
  • Valve body and closure sleeve are constructed from 304 (Schedule 40) stainless steel.
  • Approved for horizontal N pattern installation.
  • Features a flood sensor with SentryPlus Alert® technology to detect continuous discharge from the relief valve.
  • Includes OSY shutoff valves (Outside Stem and Yoke resilient seated gate valves).
  • Equipped with Link Check modules for lowest pressure loss.
  • Furnished with a cubic feet per minute meter to detect underground leaks and unauthorized water use.
  • Test cocks have a bronze body with nickel plating.
  • Bottom-mounted relief valve is made from corrosion-resistant stainless steel.
  • Groove couplings allow for easy installation and pipe alignment.
  • Replaceable check disc rubber.

Specifications

  • Size: 8 inch
  • Product Type: Reduced Pressure Detector Assembly
  • Brand: Colt™
  • Model Series: C500
  • Configuration: N Pattern Horizontal
  • Housing & Sleeve Material: 304 (Schedule 40) Stainless Steel
  • Elastomers: EPDM, Silicone, Buna 'N'
  • Link Checks: Noryl®, Stainless Steel
  • Check Discs: Reversible Silicone or EPDM
  • Test Cocks Material: Lead Free* Bronze Body
  • Pins & Fasteners Material: 300 Series Stainless Steel
  • Springs Material: Stainless Steel
  • Shutoff Valves: OSY (Outside Stem and Yoke Resilient Seated Gate Valves)
  • Bypass Meter: Cubic Feet per Minute
  • Flood Sensor: SentryPlus Alert® Technology
  • Temperature Range: 33°F - 140°F (0.5°C - 60°C)
  • Maximum Working Pressure: 175 PSI (12.1 bar)

Certificates & Approvals

  • Approved by Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California (FCCCHR-USC)
  • AWWA C511-97
  • ASSE 1047
  • CSA B64.4
  • UL Classified
  • FM Approved

FAQs

What is the primary function of the Colt C500 backflow preventer?

The Colt C500 reduced pressure detector backflow preventer assembly is designed to protect potable water supplies by preventing the reverse flow of non-potable fire protection substances due to backsiphonage or backpressure.

What material is the valve body and sleeve made from?

The entire valve body and closure sleeve of this assembly are manufactured from 304 (Schedule 40) stainless steel, ensuring durability and corrosion resistance.

Does this backflow preventer include a flood sensor?

Yes, this assembly features a flood sensor with SentryPlus Alert® technology to detect continuous water discharge from the relief valve, helping to prevent potential flooding events.

How does the flood sensor alert mechanism work?

To activate the flood sensor's alert features, an add-on sensor connection kit is required. When paired with this kit, the sensor can relay alerts for potential flooding events via options like BMS, cellular communication, or integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.

What is the purpose of the cubic feet per minute meter?

The cubic feet per minute meter included with this backflow assembly is used to detect underground leaks and monitor for unauthorized water usage from the fire sprinkler system.